DOI QR코드

DOI QR Code

Evaluation on Fire Resistance Performance of High Strength Concrete Containing Fibre

섬유혼입 고강도 콘크리트의 내화성능 평가

  • Song, Young-Chan (Architectural Research & Engineering, Daelim Industrial Co., Ltd) ;
  • Kim, Yong-Ro (Architectural Research & Engineering, Daelim Industrial Co., Ltd) ;
  • Kim, Ook-Jong (Architectural Research & Engineering, Daelim Industrial Co., Ltd) ;
  • Lee, Do-Bum (Architectural Research & Engineering, Daelim Industrial Co., Ltd)
  • Received : 2010.08.31
  • Accepted : 2010.10.05
  • Published : 2010.10.20

Abstract

The purpose of this research is to secure fundamental data on the application of fibre as a fire resistance method for more than 60 MPa high-strength concrete through an examination of mechanical properties and fire resistance performance. The results are as follows: 1) When there are less than 0.5~1.0kg/$m^3$ contents of PP and NY fibre for 60MPa and less high strength concrete, 1.0kg/$m^3$ contents of PP and NY fibre for less than 80MPa high strength concrete and 1.5kg/$m^3$ contents of NY fibre for more than 80MPa high strength concrete, the effect of fibre contents on workability and strength development is not significant. 2) Based on the result of a 3-hour fire resistance test for mock-up column, it is necessary to secure 50 mm of covering depth for the regulation of fire resistance performance of high strength concrete to the standards of The Ministry of Land, Transport and Maritime Affairs. 3) It is necessary to secure more than 400mm of column size for stable fire resistance performance.

2008년 7월 21일 고시한 국토해양부의 고강도 콘크리트 내화성능 관리기준에 따라 50MPa 이상의 고강도 콘크리트는 내화성능을 확인하여 건축물에 적용 가능하게 되었다. 이에 본 연구는 60, 80, 100MPa의 고강도 콘크리트를 대상으로 섬유종류, 섬유길이, 혼입량에 따른 콘크리트의 역학적 특성을 파악하고 아울러 피복두께에 따른 내화성능을 검토하여 국토해양부 관리기준에 만족하는지 파악하고, 초고층 건축물에 있어서 고강도 콘크리트를 적용하기 위한 내화성능 확보방안을 마련하고자 하였다.

Keywords

References

  1. Kim YR, Song YC, Jung YH, Kim OJ, Lee DB. Anexperimental study on the fire resistance properties ofhigh strength concrete using fiber for field application.Proceedings of Korea Institute of Construction 2008;8(2):187-91
  2. Song YC, Kim YR, Kim OJ, Lee DB. Evaluation of fireperformance for high strength concrete mock-up columnwith fiber by unloaded fire test. Proceedings of KoreaInstitute of Construction 2009;9(2):97-100
  3. Song YC, Kim YR, Oh JK, Kim OJ, Lee DB, Ko CH.An Experimental Study on Fire Resistance Performanceof High Strength Concrete by Fiber Contents and Depthof Concrete Cover. Proceedings of Architectural Instituteof Korea 2009;29(1):583-86
  4. Han CG. Concrete with spalling resistance, KoreaConcrete Institute 1998;10(6):5-10
  5. Pierre K, Gregoire C, Christophe G. High temperaturebehaviour of HPC with polypropylene fibres fromspalling to microstructure. Cement and ConcreteResearch 2001(31):1487-99 https://doi.org/10.1016/S0008-8846(01)00596-8