Abstract
The osteogenic potential of hydroxyapatite/poly $\varepsilon$-caprolactone composite (HA/PCL) scaffolds with matrigel was evaluated in a rat calvarial defect model. Calvarial defect formation was surgically created in Sprague Dawley rats (n = 18). HA/PCL scaffold was grafted with matrigel (M-HA/PCL group, n = 6) or without matrigel (HA/PCL group, n = 6). A critical defect group (CD group, n = 6) did not received a graft. Four weeks after surgery, bone formation was evaluated with radiography, micro computed tomography (micro CT) scanning, and histologically. No bone tissue formation was radiographically evident in the CD group. Bone tissue was radiographically evident in the HA/PCL and M-HA/PCL groups, however, there was more bone-similar opacity in the M-HA/PCL group. Micro CT analysis revealed that the bone volume of the M-HA/PCL group was higher than the HA/PCL group, however, no significant difference was found between the HA/PCL and M-HA/PCL groups. Bone mineral density in the M-HA/ PCL group was significantly higher than in the HA/PCL group (p < 0.05). Histologically, new bone was formed only from existing bone in the CD group, showing concavity without bone formation in the defect. In the HA/PCL group, new bone formation was only derived from existing bone, while in the M-HA/PCL group the largest bone formation was observed, with new bone tissue forming at the periphery of existing bone and around the HA/PCL scaffold with matrigel. The results indicate that the combination of HA/PCL scaffold with matrigel may be an effective means of enhancing bone formation in critical-sized bone defects.
본 연구에서는 hydroxyapatite/poly $\varepsilon$-caprolactone composite (HA/PCL) 지지체와 matrigel을 랫드의 두개골 결손부 모델에 함께 이식 시의 골형성 정도를 평가하였다. 두개골결손부는 Sprague Dawley rat (n = 18)에서 수술적으로 형성하였으며 실험군은 Matrigel과 함께 HA/PCL 지지체를 이식한 군(M-HA/PCL group, n = 6)과 HA/PCL 지지체단독이식군(HA/PCL group, n = 6)으로 나누었고 대조군(CD group, n = 6)에는 아무 것도 이식하지 않았다. 수술 4주 후, 골형성은 방사선촬영, micro CT 및 조직검사를 통해 평가되었다. 방사선상에서 CD군의 골형성은 관찰되지 않았으나 HA/PCL과 M-HA/PCL군에서는 관찰되었고 골과 유사한 방사선비투과성이 M-HA/PCL군에서 더 많이 관찰되었다. Micro CT 평가에서 골부피는 HA/PCL군보다 M-HA/PCL군에서 더 높았으나 두 군 사이의 유의적 차이는 관찰할 수 없었다. 그러나 골밀도에서는 HA/PCL군보다 M-HA/PCL군이 더 유의적으로 높음을 확인할 수 있었다(p < 0.05). 조직학적 검사에서는 CD군에서 새로운 골은 원래 존재하던 골로부터만 형성되었으며 두개골결손부 내의 골형성은 보이지 않았다. HA/PCL군에서 새로운 골형성은 원래 존재하던 골로부터만 유래되었으나 M-HA/PCL군은 가장 많은 골형성을 보여주었으며 새로운 골이 원래 존재하던 골과 HA/PCL지지체 주변에서도 관찰되었다. 이러한 결과로 미루어볼 때 HA/PCL 지지체와 matrigel을 함께 사용하는 것이 골의 임계결손부에서 골형성을 증대시키는 효과적인 방법이 될 수 있을 것으로 생각된다.