Acknowledgement
Supported by : 서울대학교
References
- Annable, M.D., Rao, P.S.C., Hatfield, K., Graham, W.D., Wood, A.L., and Enfield, C.G, 1998, Partitioning tracers for measuring residual NAPL: Field-scale test results, J. Environ. Eng., 124, 498-503. https://doi.org/10.1061/(ASCE)0733-9372(1998)124:6(498)
- Bedient, P.B., Rifai, H.S., and Newell, C.J., 1999, Groundwater Contamination: Transport and Remediation (2nd ed.), Prentice Hall, New Jersey.
- Brusseau, M.L., Nelson, N.T., and Cain, R.B., 1999, The partitioning tracer method for In-situ detection and quantification of immiscible liquids in the subsurtace, in: Innovative Subsurfacc Remediation, Field Testing of Physical, Chemical, and Characterization Technologies, ACS Symposium Series 725, American Chemical Society, Washington, p. 208-225.
- Cain, R,B., Johnson, G.R., McCray, J.E., Blanford, W.J., and Brusseau, M.L., 2000, Partitioning tracer test for evaluating remediation performance, J. Ground Water, 38, 752-761. https://doi.org/10.1111/j.1745-6584.2000.tb02711.x
- Cheon, J.Y., Lee, J.Y., and Lee, K.K., 2004, Characterization of the hydrogeologic environment at a petroleum hydrocarbon contaminated site in Korea, Environ. Geol., 45, 869-883. https://doi.org/10.1007/s00254-003-0949-0
- Dai, D., Barranco, Jr.F.T., and Illangasekare, T.H., 2001, Partitioning and interfacial tracers for differentiating NAPL entrapment configuration: Column-scale investigation, Environ. Sci. Technol., 35, 4894-4899. https://doi.org/10.1021/es010745k
- Davis, B.M., Istok, J.D., and Semprini, L., 2002, Push-pull partitioning tracer tests using radon-222 to quantify non-aqueous phase liquid contamination, J. Contam. Hydrol., 58, 129-146. https://doi.org/10.1016/S0169-7722(02)00010-4
- Devine, C.E., McCray, J.E., Martin, L.M.W., Blanford, W.J., Blitzer, D.J., Brusseau, M.L., and Boving, T.B., 2004, Partitioning tracer tests as a remediation metric: Case study at naval amphibious base little creek, Virginia Beach, Virginia, Remediation, J, 14, 7-31.
- Domenico, P.A. and Schwartz, F.W., 1997, Physical and Chemical Hydrogeology (2nd ed.), Wiley, New York.
- Fetter, C.W., 2001, Contaminant Hydrogeology (4th ed.), Prentice Hall, New Jersey.
- Jha, R., Singh, V.P., and Vatsa, V., 2008, Analysis of urban development of Haridwar, India, using entropy approach, KSCE J. Civ. Eng., 12, 281-288. https://doi.org/10.1007/s12205-008-0281-z
- Jin, M., Delshad, M., Dwarakanath, V., McKinney, D.C., Pope, G.A., Sepehmoori, K., Tilburg, C.E., and Jackson, R.E., 1995, Partitioning tracer test for detection, estimation, and remediation performance assessment of subsurface nonaqueous phase liquids, Water Resour: Res., 31, 1201-1211. https://doi.org/10.1029/95WR00174
- Jones, E.H. and Smith, C.C., 2005, Non-equilibrium partitioning tracer transport in porous media: 2-D physical modeling and imaging using a partitioning fluorescent dye, Water Res., 39, 5099-5111. https://doi.org/10.1016/j.watres.2005.09.044
- Lee, J.Y., Cheon, J.Y., Lee, K.K., Lee, S.Y., and Lee, M.H., 2001, Factors affecting the distribution of hydrocarbon contaminants and hydrogeochemical parameters in a shallow sand aquifer, J. Contam. Hydrol., 50, 1539-1583.
- Nelson, N.T. and Brusseau, M.L., 1996, Field study of the partitioning tracer method for detection of dense nonaqueous phase liquid in a trichloroethene-contaminated aquifer, Environ. Sci. Technol., 30, 2859-2863. https://doi.org/10.1021/es960148b
- Nelson, N.T., Oostrom, M., Wietsma, T.W., and Brusseau, M.L., 1999, Partitioning tracer method for the in situ measurement of DNAPL saturation: Influence of heterogeneity and sampling method, Environ. Sci. Technol., 33, 4046-4053. https://doi.org/10.1021/es990022p
- Rao, P.S.C., Annable, M.D., and Kim, H., 2000, NAPL source zone characterization and remediation technology performance assessment: Recent developments and applications of tracer techniques, J. Contam. Hydrol., 45, 63-78. https://doi.org/10.1016/S0169-7722(00)00119-4
- Son, Y., Oh, M., and Lee, S., 2009, Influence of diesel fuel contamination on the electrical properties of unsaturated soil at a low frequency range of 100 Hz-10 MHz, Environ. Geol., 58, 1131-1348.
- Young, C.M., Jackson, R.E., Jin, M., Londergan, J.T., Mariner, P.E., Pope, G.A., Anderson, F.J., and Houk, T., 1999, Characterization of a TCE NAPL zone in alluvium by partitioning tracers, Ground Water Monit. Remediat., 19, 84-94. https://doi.org/10.1111/j.1745-6592.1999.tb00190.x