DOI QR코드

DOI QR Code

도재용 금합금 재사용에 따른 변연 적합도에 관한 연구

A study on the marginal fitness to reuse with a Au-Pt-Pd alloy for porcelain fused to metal crown

  • 문희경 (진주보건대학 치기공과)
  • Moon, Hee-Kyung (Dept, of Dental laboratory Technology, Jin Ju Health College)
  • 투고 : 2010.01.26
  • 심사 : 2010.03.31
  • 발행 : 2010.03.30

초록

This experimental study was to determine the fitness in each cervical margin of reusing porcelain gold alloy. The gold alloy used in this experimental study was a Au-Pt-Pd alloy (BDCG-898, Bukwang Inc, Korea) for the fabrication of porcelain fused to metal crown. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of reuse to five times. Each specimen was reused without adding new metal. The experimental results were as follows: 1. The group A, B, C showed good fitness in each cervical margin. 2. The group D got good fitness in labio and linguo cervical margin, but the mesio and disto cervical margin showed more than $40{\mu}m$ 3. The group E showed worse fitness than the other groups in each cervical margin.

키워드

참고문헌

  1. 관교의치기공학교육연구회, 관교의치기공학, 개정판, 대학서림, 46, 2002
  2. 김응철, 치과기공사를 위한 치과재료학, 대학서림, 215, 1987
  3. 김정미, 정수하, 정부도재관의 변연 적합도 비교 평가, 대한치과기공학회지, 30, 2, 85-92, 2008.
  4. 김치영, 김영곤, 조현설, 도재-금속의 결합강도에 미치는 비금속 합금의 열처리 효과, 대한치과기공학회지, 24, 1, 33-41, 2002
  5. 이인규, 최운재, 치관 보철물 제작에 사용되는 비귀금속 합금의 치경부 변연에 관한 적합성, 원광보건전문대학논문집, 13, 137-140, 1990.
  6. 이종엽, Ceramo metal crown. 제 1판, 상아출판사, 9-12, 1995.
  7. 정희선, 오경재, 도재소부금관용 비귀금속 합금의 반복 주조가 강도에 미치는 영향, 대한치기공학회지, 31, 3, 27-34, 2009.
  8. 정인성, 치관보철물 제작에 사용되는 비귀금속 합금의 주조성에 관한 실험적 연구, 대한치기공학회지, 9, 1, 1987
  9. Asgar K. melting and casting of alloys. Proceedings, Altematives to gold alloys in dentistry DHEW publications, No,(NH) 77-1227:166,1977.
  10. Baran GR. The metallurgy of Ni-Cr alloys for fixed prosthodontics. J Prosthe Dent, 50:639, 1983. https://doi.org/10.1016/0022-3913(83)90201-9
  11. Bates JF, Knapton AG. Metals and alloys in dentistry. International Metals Review, 215:39-60, 1977.
  12. Craig RG. Dental materials properties and manipulation C. V. Mosby, Saint Louis, 202, 1979.
  13. Duncanson, MG. Non precious metal alloys of fixed restorative dentistry. Dent Clin North Am, 20:423, 1976.
  14. Harcourt HJ. The remelting of cobalt chromium alloys. Br Dent J, 112:198, 1962.
  15. Hesby D. Kobes AP, Graver D, Pelleu GB. Physical properties of a repeatedly used nonprecious metal alloy. J Pros Dent, 44:291, 1980. https://doi.org/10.1016/0022-3913(80)90014-1
  16. Hinman RW, Tesk JA, Whitlock RP, Parry EE, Durkowski JS. Use of a castability test for optimizing mold and casting temperature. Int Dent Res. 374, 1982.
  17. Huget EF. Basemetal crown and bridge alloys. proceedings, IADR annual meetings, London, 1978.
  18. Nitkin DA, Asger K. Evaluation of alternative alloys to type lII gold for use on fixed prosthodontics. J Am Dent Assoc, 93:383, 1974.
  19. Philips RW. Skinner's science of dental materials. 7th ed, W. B. Saunders Co, Philadelphia, 592,1973.
  20. Sced IR, McLean JW. The strength of metal ceramic bonds with base metal containing chromium. Br Dent J, 132:232-234, 1974.