DOI QR코드

DOI QR Code

PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석

Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC

  • 박상호 (한국전력공사 전력연구원 송배전연구소) ;
  • 최영도 (한국전력공사 전력연구원 송배전연구소) ;
  • 박영신 (한국전력공사 전력연구원 송배전연구소)
  • 투고 : 2010.08.10
  • 심사 : 2010.08.30
  • 발행 : 2010.09.30

초록

There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.

키워드

참고문헌

  1. Math H.J. Bollen, "Understanding Power Quality Problems-Voltage Sags and Interruptions", IEEE Press, 2000, pp2-5.
  2. M. McGranaghan, D.R. Mueller and M. J. Samotyj, "Voltage sags in industrial systems", IEEE Transactions on Industry Applications, Vol 29, No.2, March/April 1993.
  3. N.G. Hingorani and L.Gyugyi, "Understanding FACTS", IEEE Press, 2000, pp 19.
  4. 국내 전력계통특성을 고려한 전력품질향상기기 실증시험 기술개발 연구, 최종보고서, 2005.
  5. B.Han "Dynamic Voltage Compensator for Sudden Voltage Drop", KIEE Trans. on Electrical Engineering, Vol. 47, No. 8, August, 1988.