Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma

간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교

  • Kang, Sin-Chang (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Park, Hoon-Hee (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jung-Yul (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lim, Han-Sang (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae-Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lee, Chang-Ho (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System)
  • 강신창 (연세의료원 세브란스병원 핵의학과) ;
  • 박훈희 (연세의료원 세브란스병원 핵의학과) ;
  • 김정열 (연세의료원 세브란스병원 핵의학과) ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 이창호 (연세의료원 세브란스병원 핵의학과)
  • Received : 2010.08.30
  • Accepted : 2010.09.13
  • Published : 2010.10.30

Abstract

Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

$^{11}C$-Acetate PET/CT는 간에 관련된 병변을 찾아내는데 있어 유용성이 있으며, 이에 대한 예민도는 87.3%에 이른다. 이에 반해 $^{18}F$-FDG PET/CT의 예민도는 47.3%이며, $^{18}F$-FDG와 $^{11}C$-Acetate PET/CT 검사를 동시에 사용하는 경우 예민도는 100%로 보고된바 있다. 하지만 $^{11}C$-Acetate PET/CT검사에서 췌장, 비장의 정상섭취로 인해 $^{18}F$-FDG PET/CT검사에 영향을 줄 수 있어 정확한 진단에 혼란을 야기시킬 수 있다. 본 연구는 이러한 두 방사성의약품의 사용으로 인하여 영상에 얼마나 영향을 주는지에 대해 당일 검사법과 양일 검사법 간의 비교 분석을 통해 유용성을 확인하는데 목적이 있다. 본 연구는 2007년 12월부터 2009년 7월까지 본원에서 간암 진단을 받고 PET/CT 검사를 시행한 환자 46명을 대상으로 하였다(남자 35명, 여자 11명, 평균연령: $54{\pm}10.6$세, 연령 범위: 29~69세). 검사에 이용된 장비는 Biograph TruePoint 40 PET/CT이며, 당일 검사법으로 검사한 21명에게는 $^{11}C$-Acetate PET/CT 검사를 먼저 시행하고 약 1시간 후에 곧바로 $^{18}F$-FDG PET/CT 검사를 시행하였다. 양일 검사법으로 검사를 시행한 25명에게는 1일째 $^{11}C$-Acetate PET/CT검사를 시행하고, 2일째 $^{18}F$-FDG PET/CT 검사를 시행하였다. 두 검사법 간의 $^{18}F$-FDG 영상에서 췌장과 비장에 동일한 관심영역을 설정하고 표준섭취계수를 측정하여 비교 평가하였다. 통계 분석은 SPSS Ver. 17을 사용하였으며, unpaired t-test를 통하여 두 검사법 간의 통계적 유의성을 확인하였다. 각각의 검사법으로 시행한 환자의 영상을 분석한 결과, 양일 검사법으로 검사를 시행한 환자의 췌장 부분의 표준섭취계수 평균${\pm}$표준편차는 두부 $1.62{\pm}0.32$ g/mL, 체부 $1.57{\pm}0.37$ g/mL, 미부 $1.49{\pm}0.33$ g/mL, 비장은 $1.53{\pm}0.28$ g/mL였다. 당일 검사법으로 검사를 시행한 환자의 췌장은 두부 $1.65{\pm}0.35$ g/mL, 체부 $1.58{\pm}0.27$ g/mL, 미부 $1.49{\pm}0.28$ g/mL, 비장은 $1.66{\pm}0.29$ g/mL로 나타났다. 당일 검사법과 양일 검사법 간의 췌장과 비장에서의 표준섭취계수는 통계적으로 유의한 차이를 보이지 않았으며 (p<0.05), PET/CT 영상분석에서도 위양성으로 오인할 수 있는 높은 섭취는 보이지 않았다. 본 연구를 통해서 하루 동안 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사를 시행하여도 $^{18}F$-FDG 영상에서 $^{11}C$-Acetate의 영향으로 인해 표준섭취계수의 과대평가가 일어나지 않는다는 것을 알 수 있었고 이는 표준섭취계수의 측정값을 통해 통계적으로 유의성을 확인할 수 있었다. 앞으로 $^{11}C$-Acetate가 상용화될 경우 $^{18}F$-FDG와 당일 검사법을 이용하여 간질환의 진단에 있어 PET/CT 검사의 진단능을 향상시킬 수 있고 위 결과를 토대로 두 방사성의약품의 간섭영향 없이 하루에 검사를 완료할 수 있으며, 대기시간을 단축하여 환자의 만족도를 높일 수 있을 것으로 사료된다.

Keywords