Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections

프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능

  • 최현기 (한양대학교 건축환경공학과) ;
  • 최윤철 (청운대학교 건축설비소방학과) ;
  • 최창식 (한양대학교 건축공학과)
  • Received : 2010.01.15
  • Accepted : 2010.08.04
  • Published : 2010.08.31

Abstract

Five half-scale beam-to-column connections in a precast concrete frame were tested with cyclic loading that simulated earthquake-type motions. Five half -scale interior beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including one monolithic specimen and four precast specimens. Variables included the detailing used at the joint to achieve a structural continuity of the beam reinforcement, and the type of special reinforcement in the connection (whether ECC or transverse reinforcement). The specimen design followed the strong-column-weak-beam concept. The beam reinforcement was purposely designed and detailed to develop plastic hinges at the beam and to impose large inelastic shear force demands into the joint. The joint performance was evaluated on the basis of connection strength, stiffness, energy dissipation, and drift capacity. From the test results, the plastic hinges at the beam controlled the specimen failure. In general, the performance of the beam-to-column connections was satisfactory. The joint strength was 1.15 times of that expected for monolithic reinforced concrete construction. The specimen behavior was ductile due to tensile deformability by ECC and the yielding steel plate, while the strength was nearly constant up to a drift of 3.5 percent.

프리캐스트 콘크리트 골조에서 실물크기의 보-기둥 접합부 실험체 5개를 대상으로 반복가력 실험을 수행하였다. 지진하중을 받는 골조를 대상으로 1개의 일체식 실험체와 4개의 프리캐스트 실험체를 포함하여 5개의 1/2스케일의 내부 보-기둥 접합부를 대상으로 하였다.주요 변수는 보의 구조적 연속성을 확보하기 위한 접합부의 형태와 접합부의 특별한 보강형태(섬유콘크리트와 횡보강근)로 하였다. 실험체는 강기둥-약보 개념에 따라 설계하였다. 보 철근은 접합부에 큰 비탄성 전단력이 작용할 경우 보에 소성힌지가 발생하도록 계획하였다. 접합부의 성능평가는 접합부의 강도, 강성, 에너지 소산능력과 층간변위비로 평가하였다. 실험결과 실험체의 파괴는 보의 소성힌지부에서 파괴되었다. 보-기둥 접합부의 성능은 대체적으로 우수한 것으로 나타났다. 접합부의 강도는 일체식 RC 구조의 비해 1.15배 정도 향상되었다. 층간변위 3.5%때의 강도에서 실험체는 ECC의 인장변형능력과 철골연결재의 항복에 의해 연성거동 하였다.

Keywords

References

  1. Restrepo, J.I., Park, R., and Buchanan, A.H., “Test on Connections of Earthquake Resisting Precast Reinforced Concrete Perimeter Frames of Buildings,” PCI Journal, Vol. 40, No. 4, 44-61, 1995.
  2. 김승훈, 류갑청, 하상수, 문정호, 이리형, “철근 관통형 프리캐스트 콘크리트 보-기둥 외부접합부의 구조적 거동에 관한 실험적 연구,” 대한건축학회 논문집, 제22권, 3-10, 2006.
  3. 이정윤, 채희대, “지진하중을 받는 철근콘크리트 접합부의 강도,” 한국지진공학회 논문집, 제 10권, 25-33, 2006. https://doi.org/10.5000/EESK.2006.10.5.025
  4. Lee, J.Y., Kim, J.Y. Oh, G.J., “Strength Deterioration of reinforced Beam-Column Joints Subjected to Cyclic Loading,” Engineering Structures, Article in press, 2009.
  5. 송영수, 유승룡, “반복하중을 받는 프리캐스트 콘크리트 건식 보-기둥 연결부의 거동분석,” 한국콘크리트학회 논문집, Vol. 18, No. 4, 497-506, 2006. https://doi.org/10.4334/JKCI.2006.18.4.497
  6. Soubra, K.S., Wight, J.K., and Naaman, A.E., “Cyclic Response of Fibrous Cast-in-Place Connections in Precast Beam-Column Subassemblages,” ACI Journal, Vol. 90, No. 3, 316-32, 1993.
  7. Sergio, M.A., Rene, Carranza, S.E., David Perez-Navarrete, M.SC., and Raul Martinenz, S.E., “Seismic Tests of Beam-to-column Connections in a Precast Concrete Frame,” PCI Journal, May-June, 70-89, 2002.
  8. Khaloo, A.R., and Parastesh, H., “Cyclic Loading of Ductile Precast Concrete Beam-Column Connection,” ACI Journal, Vol. 100, No. 3, 291-296, 2003.
  9. Abdel-Fattah, B.A., Wight, J. K., “Study of Moving Beam Plastic Hinging Zones for Earthquake Resistiong Design of RC Buildings,” ACI Structural Journal, 31-39, 1987.
  10. ACI Committe 318, “Building Code Requirement for Structural Concrete,” American Concrete Institute, 2005.
  11. 한국콘크리트학회, “콘크리트구조설계기준,” 2007
  12. ACI 352R-91, “Recommendations for Design of Beam Column Joints in Monolithic Reinforced Concrete Structures,” ACI Manual of Concrete Practice, ACI, 1-9, 2002.
  13. Bracci., J.M. Dooley, K.L., “Effect of Column Yielding During Earthquake For Reinforced Concrete Frame,” ACI Journal, 2003.
  14. Ehsani, M.R., Wight, J.K.,“Exterior Reinforced Concrete Beam-Column Connection Subjected to Earthquake Type Loading,” ACI Journal Proceeding, Vol. 82, No. 82-43, 492-499, 1985.
  15. 이광수, 오정근, 문정일, 권영호, 신성우,“반복하중을 받는 고강도 철근콘크리트 보-기둥 접합부의 휨강성비에 관한 연구,” 한국콘크리트학회학술발표대회, 제2권, 63-67, 1990.
  16. 이정윤, 김진영, 오기동, “철근콘크리트 보-기둥 내부 접합부의 전단거동에 관한 실험적 연구,” 한국콘크리트학회논문집, 제 19권, 441-448, 2007.
  17. ACI T1.1R-01, “Commentary on Acceptance Criteria for Moment Frames Based on Structural Testing,” ACI Manual of Concrete Practice, ACI, 1-7, 2002.
  18. Ehsani, M. R, Alameddin, F., “Design Recommendations for Type2 High-Strength Reinforced Concrete Connections,” ACI Structural Journal, Vol. 88, No. 3, 277-291, 1991.

Cited by