DOI QR코드

DOI QR Code

D-q Equivalent Circuit-based Protection Algorithm for a Doubly-fed Induction Generator in the Time Domain

  • Kang, Yong-Cheol (Dep. of Electrical Engineering, Chonbuk National University) ;
  • Kang, Hae-Gweon (Dep. of Electrical Engineering, Chonbuk National University) ;
  • Lee, Ji-Hoon (Dep. of Electrical Engineering, Chonbuk National University)
  • Received : 2010.02.05
  • Accepted : 2010.04.05
  • Published : 2010.09.01

Abstract

Most modern wind turbines employ a doubly-fed induction generator (DFIG) system due to its many advantages, such as variable speed operation, relatively high efficiency, and small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. We propose a protection algorithm for a DFIG based on a d-q equivalent circuit in the time domain. In the DFIG, the voltages and currents of the rotor side and the stator side are available. The proposed algorithm estimates the instantaneous induced voltages of magnetizing inductance using those voltages and currents from both the stator and the rotor sides. If the difference between the two estimated induced voltages exceeds the threshold, the proposed algorithm detects an internal fault. The performance of the proposed algorithm is verified under various operating and fault conditions using a PSCAD/EMTDC simulator.

Keywords

References

  1. J. B. Ekayanake, L. Holdsworth and N. Jenkins, Controlof Doubly Fed Induction Generator (DFIG) WindTurbines.
  2. T. Ackermann, Wind Power in Power Systems, JohnWiley & Sons, Ltd.
  3. L. H. Hansen, L. Helle, F. Blaabjerg, E. Ritchie, S.Munk-Nielsen, H. Bindner, P. Soerensen and B. Bak-Jensen, “Conceptual survey of Generators and PowerElectronics for Wind Turbines,” Risoe-R-1205(EN),Risoe National laboratory, December, 2001.
  4. Dr. Eggert and S. Franko, “Innovative Variable SpeedDrive for Doubly Fed Wind Turbine Application,”2002 World Wind Energy Conference and Exhibition,July, 2002.
  5. R. Pena, J. C. Clare and G. M. Asher, “Doubly fedinduction generator using back-to-back PWM convertersand its application to variable-speed windenergygeneration,” IEE Proc.-Electr., Power Appl.,Vol. 143, No. 3, pp. 231-241, May 1996. https://doi.org/10.1049/ip-epa:19960288
  6. J. Yang, S. B. Lee, J. Yoo, S. Lee, Y. Oh and C. Choi,“A Stator Winding Insulation Condition MonitoringTechnique for Inverter-Fed Machines,” Power Electronics,IEEE Transactions on, Vol. 22, No. 5, pp.2026-2033, Sept. 2007. https://doi.org/10.1109/TPEL.2007.904236
  7. V. Dinkhauser and F. W. Fuchs, “Detection of rotorturn-to-turn faults in doubly-fed induction generatorsin wind energy plants by means of observers,” PowerElectronics and Applications, 2009. EPE '09. 13thEuropean Conference on, Sept. 2009.
  8. Generator Protection, IEEE Recommended practicefor protection and coordination of industrial andcommercial power systems.
  9. A. R. Bergen and V. Vittal, “Power System Analysis2nd edition,” Prentice Hall Inc., pp. 514-516, 2000.
  10. A. Siddique, G. S. Yadava and B. Singh, “A review ofstator fault monitoring techniques of induction motors,”Energy Conversion, IEEE Transaction on, Vol.20, No. 1, pp. 106-114, Mar. 2005. https://doi.org/10.1109/TEC.2004.837304
  11. P. C. Krause, O. Wasynczuk and S. D. sudhoff, Analysis of Electric Machinery and Drive Systems, Wiley Interscience, 2002.
  12. G. R. Slemon and A. Straughen, Electirc Machines,Addison-Wesley Publishing Company, Oct. 1982.
  13. W. Leonhard, Control of electrical drives, Springer-Verlag, 2nd edition, 1996.
  14. L. Morel, H. Godgroid, A. Mirzaian and J. M.Kauffmann, “Doubly-fed induction machine: converteroptimization and field oriented control with outposition sensor,” IEE Proc.-Electr., Power Appl., Vol.145, No. 4, pp. 360-368, July, 1998. https://doi.org/10.1049/ip-epa:19981982
  15. Z. Cai, A. Gao and J. Jiang, “Modeling for InteriorFaults of Induction Motors and Its Simulation onEMTDC,” IPST 2003 in New Orleans, USA.

Cited by

  1. Design and evaluation of voltage measurement-based sectoral diagnosis method for inverter open switch faults of permanent magnet synchronous motor drives vol.6, pp.8, 2012, https://doi.org/10.1049/iet-epa.2011.0315
  2. Doubly fed induction generator wind turbines: A novel integrated protection circuit for low-voltage ride-through strategy vol.6, pp.5, 2014, https://doi.org/10.1063/1.4899076