Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line

초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석

  • 임재섭 (한국전력공사 전력연구원 송배전연구소) ;
  • 신구용 (한국전력공사 전력연구원) ;
  • 이동일 (한국전력공사 전력연구원) ;
  • 주문노 (한국전기연구원 스마트그리드 연구본부 전기환경송전연구센터) ;
  • 양광호 (한국전기연구원 스마트그리드 연구본부 전기환경송전연구센터)
  • Received : 2010.07.12
  • Accepted : 2010.08.19
  • Published : 2010.09.01

Abstract

HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

Keywords

References

  1. HVDC Transmission Line Reference Book, Electric Power Research Institute(EPRI), pp 4-76-4-81, 1993
  2. P. Sarma Maruvada, Serge Drogi, "Field and ion interactions of hybrid AC/DC transmission lines", IEEE Transactions on Power Delivery, Volume 3, No. 3, July 1988
  3. Michael G. Comber, Gary B. Johnson, "HVDC Field and Ion Effects Research at Project UHV Results of Electric Field and Ion Current Measurements", IEEE Transactions on Power Delivery, Vol. PAS-101, No. 7, July 1982
  4. Mitsura Yasui, Yochi Takahashi, A. Takenaka, K. Naito, Y. Hasegawa, K. Kato, "RI, TVI, and AN Characteristics of HVDC Insulator Assemblies under Contaminated Condition", IEEE Transactions on Power Delivery, Vol. 3, No. 4, pp.1913-1921, 1988 https://doi.org/10.1109/61.194000
  5. P. Sarma Maruvada, Corona Performance of High-Voltage Transmission Lines, Research Studies Press LTD, pp 113-118, 2000
  6. Mazen abdel-Salam, Hussein Anis, Ahdab El-Morshedy, Roshdy Radwan, "High-Voltage Engineering Theory and Practice", Marcel DEKKENR, pp. 150∼163
  7. 주문노, 양광호, 이동일, 신구용, 임재섭, "초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발". 대한전기학회논문지, 11호, 57권, pp. 2035∼2040, 2008
  8. 電力中央硏究所 硏究報告 T88095, "塩原UHV直流試驗 線におけるイオン流場に及ぼす風速の影響" pp 11-43, 1993
  9. 電力中央硏究所 硏究報告 184016, "塩原UHV直流試驗 線によるイオン流およびコロナ特性の基礎硏究(II)-イオ ン流と電界に及ぼす全線地上高と極間距離の影響-" pp 16-35, 1984
  10. Matthew Wright, "POWER FREQUENCY EMFs AND HEALTH RISK", Physics & Law Group, Institute of Physics 4th, 2007