Abstract
This study was performed to evaluate the PCBs-containing wastes using official test method. Ninety samples of transformer oil and various solid waste were collected to assess the analytical results. In the analysis of PCBs-containing wastes, the PCBs levels were detected in the range of 7.6 mg/kg to 23.8 mg/kg for transformer oils, $0.02\sim0.54\;{\mu}g/100cm^2$ for plat solid wastes, and 0.01~0.071 mg/kg for amorphous solid waste. In the cupper wire waste of the transformer with oil concentration level of 23 mg/kg, the analytical result exceed PCBs regulation level of 0.04 mg/kg. The new proposed analytical method for PCBs containing waste can be forced to effective management of the wastes.
본 연구에서는 최근 제안된 PCBs 함유 고상폐기물 공정시험방법을 토대로 PCBs 함유 변압기에서 90건의 시료를 채취 분석하였으며, 제시한 분석방법의 폐기물 시료에 적정성 여부를 검토하였다. 채취한 변압기 절연유에서의 PCBs 농도범위는 7.6~23.8 mg/L로 나타났으며, 규소강판은 $0.02\sim0.54\;{\mu}g/100cm^2$의 농도범위로 검출되었다. 또한, 구리선 등의 비정형 폐기물은 0.01~0.071 mg/kg의 농도범위로 검출 되었다. 본 연구 결과, 폐기물공정시험방법의 새로운 분석방법과 규제기준은 기존의 용출시험방법으로 고상폐기물을 관리하는 경우에 비해 PCBs 함유 폐기물의 관리가 보다 강화된 것으로 판단된다.