DOI QR코드

DOI QR Code

Experimental study on reinforced high-strength concrete short columns confined with AFRP sheets

  • Wu, Han-Liang (School of Civil Engineering, Beijing Jiaotong University) ;
  • Wang, Yuan-Feng (School of Civil Engineering, Beijing Jiaotong University)
  • Received : 2010.01.23
  • Accepted : 2010.10.29
  • Published : 2010.11.25

Abstract

This paper is aiming to study the performances of reinforced high-strength concrete (HSC) short columns confined with aramid fibre-reinforced polymer (AFRP) sheets. An experimental program, which involved 45 confined columns and nine unconfined columns, was carried out in this study. All the columns were circular in cross section and tested under axial compressive load. The considered parameters included the concrete strength, amount of AFRP layers, and ratio of hoop reinforcements. Based on the experimental results, a prediction model for the axial stress-strain curves of the confined columns was proposed. It was observed from the experiment that there was a great increment in the compressive strength of the columns when the amount of AFRP layers increases, similar as the ultimate strain. However, these increments were reduced as the concrete strength increasing. Comparisons with other existing prediction models present that the proposed model can provide more accurate predictions.

Keywords

References

  1. Almusallam, T.H. (2007), "Behavior of normal and high-strength concrete cylinders confined with E-glass/epoxy composite laminates", Compos. Part B-Eng., 38(5-6), 629-639. https://doi.org/10.1016/j.compositesb.2006.06.021
  2. Almusallam, T.H., and Alsayed, S.H. (1995), "Stress-strain relationship of normal, high-strength and lightweight concrete", Mag. Concrete. Res., 47, 39-44. https://doi.org/10.1680/macr.1995.47.170.39
  3. American Concrete Institute (1984), "State of the art report of high-strength concrete", ACI 363R-84, ACI-363 Committee, Detroit.
  4. Candappa, D.P., Sanjayan, J.G. and Setunge, S. (2001), "Complete triaxial stress-strain curves of high-strength concrete", J. Mater. Civil. Eng., 13(3), 209-215. https://doi.org/10.1061/(ASCE)0899-1561(2001)13:3(209)
  5. Fam, A. Z. and Rizkalla, S.H. (2001), "Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes", ACI Struct. J., 98(4), 451-461.
  6. Karabinis, A.I. and Rousakis, T.C. (2002), "Concrete confined by FRP materials: a plasticity approach", Eng. Struct., 24(7), 923-932. https://doi.org/10.1016/S0141-0296(02)00011-1
  7. Lam, L. and Teng, J.G. (2002), "Stress-strain model for FRP-confined concrete", Constr. Build. Mater., 17, 471-489.
  8. Li, Y.F., Lin, C.T. and Sung, Y.Y. (2002), "A constitutive model for concrete confined with carbon fiber reinforced plastics", Mech. Mater., 35(3-6), 603-619.
  9. Li, Y.F., Fang, T.S. and Chern, C.C. (2003), "A constitutive model for concrete cylinder confined by steel reinforcement and carbon fiber sheet", Proceedings of Pacific Conference on Earthquake Engineering, New Zealand, Feb.
  10. Li, G.Q. (2006), "Experimental study of FRP confined concrete cylinders", Eng. Struct., 28(7), 1001-1008. https://doi.org/10.1016/j.engstruct.2005.11.006
  11. Lin, H.J. and Liao, C.I. (2003). "Compressive strength of reinforced concrete column confined by composite material", Compos. Struct., 65(2), 239-250.
  12. Lin, H.J., Liao, C.I. and Yang, C. (2006), "A numerical analysis of compressive strength of \r\nrectangular concrete columns confined by FRP", Comput. Concrete, 3(4), 57-68.
  13. Lokuge, W.P., Sanjayan, J.G. and Setunge, S. (2005), "Stress-strain model for laterally confined concrete", J. Mater. Civil. Eng., 17(6), 607-616. https://doi.org/10.1061/(ASCE)0899-1561(2005)17:6(607)
  14. Lorenzis, L.D. (2001), "A comparative study of models on confinement of concrete cylinders with FRP composites", Research Rep. Prepared of Chalmers Univ. Of Technology, Goteborg, Sweden.
  15. Mirmiran, A. and Shahawy, M. (1997), "Behavior of concrete columns confined by fiber composites", J. Struct. Eng., 123 (5), 583-590. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:5(583)
  16. Mortazavi, A.A., Pilakoutas, K. and Son, K.S. (2003), "RC column strengthening by lateral pre-tensioning of FRP", Constr. Build. Mater., 17(6-7), 491-497. https://doi.org/10.1016/S0950-0618(03)00046-1
  17. Richard, R.M. and Abbott, B.J. (1975), "Versatile elastic-plastic stress-strain formula", J. Eng. Mech., 101(4), 511-515.
  18. Saafi, M., Toutanji, H.A. and Li, Z. (1999), "Behavior of concrete columns confined with fiber reinforced polymer tubes", ACI Mater. J., 96(4), 500-509.
  19. Samaan, M., Mirmiran, A. and Shahawy, M. (1998), "Model of concrete confined by fiber composites", J. Struct. Eng., 124(9), 1025-1031. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:9(1025)
  20. Tabash, S.W. (2007), "Stress-strain model for high-strength concrete confined by welded wire fabric", J. Mater. Civil. Eng., 19(4), 286-294. https://doi.org/10.1061/(ASCE)0899-1561(2007)19:4(286)
  21. Teng, J.G., and Lam, L. (2004), "Behavior and modeling of fiber reinforced polymer-confined concrete", J. Struct. Eng., 130(11), 1731-1723.
  22. Xiao, Y. and Wu, H. (2000), "Compressive behavior of concrete confined by carbon fiber composite jackets", J. Mater. Civil. Eng., 12(2), 139-146 https://doi.org/10.1061/(ASCE)0899-1561(2000)12:2(139)
  23. Yeh, F.Y. and Chang, K.C. (2007), "Confinement efficiency and size effect of FRP confined circular concrete columns", Struct. Eng. Mech., 26(2), 127-150. https://doi.org/10.12989/sem.2007.26.2.127

Cited by

  1. Compressive behavior of CFFT with inner steel wire mesh vol.133, 2015, https://doi.org/10.1016/j.compstruct.2015.07.075
  2. Reliability assessment of confinement models of carbon fiber reinforced polymer-confined concrete vol.35, pp.12, 2016, https://doi.org/10.1177/0731684416633899
  3. An Artificial Neural Networks model for the prediction of the compressive strength of FRP-confined concrete circular columns vol.140, 2017, https://doi.org/10.1016/j.engstruct.2017.02.047
  4. Behavior of flax FRP tube encased recycled aggregate concrete with clay brick aggregate vol.136, 2017, https://doi.org/10.1016/j.conbuildmat.2017.01.046
  5. FRP-confined concrete in circular sections: Review and assessment of stress–strain models vol.49, 2013, https://doi.org/10.1016/j.engstruct.2012.06.010
  6. Improving strength, stiffness and ductility of CFDST columns by external confinement vol.75, 2014, https://doi.org/10.1016/j.tws.2013.10.009
  7. Behavior in compression of concrete cylinders externally wrapped with basalt fibers vol.69, 2015, https://doi.org/10.1016/j.compositesb.2014.10.008
  8. Reinforced high-strength concrete square columns confined by aramid FRP jackets -part II: modeling vol.11, pp.4, 2010, https://doi.org/10.12989/scs.2011.11.4.325
  9. Reinforced high-strength concrete square columns confined by aramid FRP jackets -part I: experimental study vol.11, pp.6, 2010, https://doi.org/10.12989/scs.2011.11.6.455
  10. Uni-axial behaviour of normal-strength concrete-filled-steel-tube columns with external confinement vol.3, pp.6, 2012, https://doi.org/10.12989/eas.2012.3.6.889
  11. Peak Strength Expression for Concrete Confined with Fiber-Reinforced Polymer vol.4, pp.3, 2018, https://doi.org/10.1061/ajrua6.0000977
  12. Evaluation of Existing Stress-Strain Models and Modeling of PET FRP-Confined Concrete vol.31, pp.12, 2010, https://doi.org/10.1061/(asce)mt.1943-5533.0002941
  13. Design-oriented strength and strain models for GFRP-wrapped concrete vol.26, pp.3, 2010, https://doi.org/10.12989/cac.2020.26.3.293
  14. Cyclic response of rectangular RC columns retrofitted by hybrid FRP sheets vol.28, pp.None, 2010, https://doi.org/10.1016/j.istruc.2020.09.016
  15. New mechanics-based confinement model and stress-strain relationship for analysis and design of concrete columns wrapped with FRP composites vol.33, pp.None, 2010, https://doi.org/10.1016/j.istruc.2021.06.012