Abstract
The transfer slab system is a structural system that transfers the loads from the upper shear wall structure to the lower columns. This is a costly system due to a very thick slab, and the relatively high cost can be mitigated by introducing voids in the slab. However, this system of flat plate containing voids is vulnerable to brittle failure caused by punching shear in vicinity of slab-column connection. Thus, the punching shear capacity of the void system is very important. However, the current code doesn't provide a clear design provision for the strength of slabs with a void section. In this study, experimental study was conducted to investigate the punching shear strength of the void slab system. The shear strength of the specimens was predicted by current code and previous researches. In result, the punching shear strength of the void system is determined as the least value calculated at critical section located a distance d/2 from the face of the column and the center of the void section using the effective area at critical section.
전이슬래브 시스템은 상부 전단벽 구조로부터 하부 기둥으로 하중을 전달하는 구조시스템이다. 이 시스템은 상당한 두께의 슬래브를 필요로 하므로 비경제적이며, 이 단점은 슬래브내에 중공부를 두어 해결할 수 있다. 그리고 이 시스템은 플랫플레이트 구조로써 기둥-슬래브 접합부 부근의 뚫림전단파괴을 일으키는 취성파괴의 위험이 존재한다. 따라서 중공부를 갖는 전이슬래브 시스템의 뚫림전단 성능은 매우 중요하다. 그러나 현행 기준에서는 중공부를 갖는 슬래브의 뚫림전단성능에 대한 명확한 강도산정 규정이 제시되어 있지 않다. 이 연구에서는 중공 시스템의 뚫림전단강도를 알아보기 위하여 실험적 연구를 수행하였으며, 현행기준 및 기존연구를 토대로 실험체의 전단강도를 예측하였다. 그 결과, 중공시스템의 뚫림전단강도는 기둥면으로부터 위험단면 d/2의 위치와 중공부 중심에서의 위험단면으로 계산된 값 중 작은 값으로 결정되었다. 여기서 강도 계산을 위하여 위험단면의 유효단면적을 사용하여 계산하였다.