초록
This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. This result has same decreasing proportion to tensile strength of the material. Resistant capacity change of beam varying with recycled powder mixture has been decreased down to 60% of normal concrete bean capacity, while there are 80% decrease of material strength. But strength and capacity change has same consistent decrease ratio. It is found that recycled powder with approximately 15% unit concrete volume can be replaced with cement in reasonable admixture mixing condition.