Effects of Pressure Tapping Conditions on Flow Rate Measurement of Triangular Separate Bar Differential Pressure Flow Meter

삼각 분리 막대형 차압유량계 압력탭 조건이 유량 측정에 미치는 영향

  • Lee, Choong-Hoon (Department of Automotive Engineering, Seoul National University of Technology)
  • 이충훈 (서울산업대학교 자동차공학과)
  • Received : 2009.12.07
  • Accepted : 2010.04.04
  • Published : 2010.04.30

Abstract

Flow characteristics of differential pressure flow meters which have a shape of triangular separate bar (TSB) was investigated according to the machining conditions in pressure tapping holes. Diameter of the pressure taping holes is either 1.0 mm or 1.5 mm. Also, number of the pressure tapping holes are drilled either 9 or 17. The mass flow rate of the TSB flow meters are calibrated with a laminar flow meter by connecting them in line. The mass flow rate in the TSB flow meters are plotted with a non-dimensional parameter H which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters. An empirical correlation between the mass flow rate at the TSB flow meter and the non-dimensional parameter H was obtained. The empirical correlation showed highly linear relationship between the mass flow rate and the non-dimensional parameter H. The hole size of the pressure tapping holes has a bigger effect on the flow rate than the number of the tapping holes.

Keywords

References

  1. 한국표준협회, 조임 기구에 의한 유량 측정 방법, KSA0612, 1997.
  2. K. Tsuchiya, S. Ogata and M. Ueta, "Karman vortex flow meter", Bull. JSME 58, pp. 573-582, 1970.
  3. C.O. Popiel, J.T. Turner and D.I. Robinson, "Evolution of an improved vortex generator", Flow Measurement and Instrumentation, Vol. 4, pp. 249-259, 1993. https://doi.org/10.1016/0955-5986(93)90032-E
  4. Rosemount Product Data Sheet, Diamond II-$Annubar^{\circledR}$ bar Primary Flow Element, Dieterich, A Subsidiary of Rosemount Inc., 1998.
  5. W.S. Wayne, E. R. Corrigan, R. J. Atkinson, N. Clark, and D.W. Lyons, "Measuring Diesel Emissions with a Split Exhaust Configuration", SAE paper No. 2001- 01-1949, 2001.
  6. K.I. Kim, W.Y. Yoo and C.H. Lee, "A Study on Flow Rate Characteristics of a Triangular Separate Bar Differential Pressure Flow Meter according to the Variation of Gas Flow Temperature", KSMTE, Vol. 17, No. 4, pp. 89-94, 2008.
  7. 이충훈, 김광일, 김민창, 박동선, "디젤엔진 배기가스 유량 측정용 삼각 분리 막대형 차압유량계 유량 특성 연구", 한국철도학회 논문집, 제10권, 제5호, pp. 563-568, 2007.
  8. H. Nakamura, N. Kihara, M. Adachi and K. Ishida, "Development of a Wet-Based NDIR and Its Application to On-Board Emission Measurement System", SAE Paper No. 2002-01-0612, 2002.
  9. Systec Control, "Precision and Process Viability of the deltaflow Dynamic Pressure Probe", Research report, http://systec-controls.de/files/deltaflow_research_report_e.pdf., 2008.