초록

Purpose: This study was performed to compare sintering conditions for fabrication of porous Ti implant. Methods: The porous Ti implant samples were fabricated by sintering of spherical Ti powders in vacuum and atmosphere conditions. Surface morphology, composition and phase were analyzed by FE-SEM, EDX and XRD. Results: Sintered Ti implant in the vacuum consisted of particles connected in three dimensions by clear necking without excessive oxide layers. However, sintered Ti implant in atmosphere was formed excessive oxide layers with non-stoichiometric compounds. Conclusion: The porous Ti implant can be sintered in vacuum condition preferably.

키워드

참고문헌

  1. 박노광, 홍재근, 김정한, 염종택. 타이타늄 분말합금의 제조와 특징. 기계와재료, 136-145, 2009.
  2. 조유정, 김영훈, 장형순, 강태주, 이원희. 다공성 티타늄 임플란트의 생체적합성 증진을 위한 복합 표면처리에 관한 연구. 한국재료학회지, 18(5), 229-234, 2008.
  3. 현창용, 허재근, 이원희. 전기방전소결에 의한 다공성 Ti 임플란트의 제조. 생체재료학회지, 9(3), 132-137, 2005.
  4. Amigo V, Salvador MD, Romero F. Microstructural evolution of Ti-6Al-4V during the sintering of microspheres of Ti for orthopedic implants. Journal of materials processing technology, 141, 117-122, 2003. https://doi.org/10.1016/S0924-0136(03)00243-7
  5. Kim YH, Cho YJ, Lee CM, Kim SJ, Lee NS, Kim KB, Jeon EC, Sok JH, Park JS, Kwon H, Lee KB, Lee WH. Self-assembled microporous Ti-6Al-4V implant compacts induced by electro-discharge-sintering. Scripta Materialia, 56, 449-451, 2007. https://doi.org/10.1016/j.scriptamat.2006.12.003