배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석

Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System

  • 김도환 (K-water연구원 상하수도연구소) ;
  • 이두진 (K-water연구원 상하수도연구소) ;
  • 김경필 (K-water연구원 상하수도연구소) ;
  • 배철호 (K-water연구원 상하수도연구소) ;
  • 주혜은 (K-water연구원 상하수도연구소)
  • Kim, Do-Hwan (Water Research Center, K-water Research Institute, Korea Water Resources Corporation) ;
  • Lee, Doo-Jin (Water Research Center, K-water Research Institute, Korea Water Resources Corporation) ;
  • Kim, Kyoung-Pil (Water Research Center, K-water Research Institute, Korea Water Resources Corporation) ;
  • Bae, Chul-Ho (Water Research Center, K-water Research Institute, Korea Water Resources Corporation) ;
  • Joo, Hye-Eun (Water Research Center, K-water Research Institute, Korea Water Resources Corporation)
  • 투고 : 2010.06.04
  • 심사 : 2010.10.20
  • 발행 : 2010.10.31

초록

일반적으로 정수처리 공정에서 염소에 의한 소독공정은 수인성 질병을 억제하고 상수도관망에서 미생물의 재성장을 억제하는 목적으로 사용되고 있다. 그러나 염소소독은 수중의 유기물과 반응하여 소독부산물(Disinfection By-products; DBPs) 과 같은 발암성 물질을 생성함으로 적절한 염소 주입이 필요하고 최근에는 관말지역에서의 잔류염소 확보를 위해 상수관로 나 배수지 등에서 재염소를 실시하는 경향이 증가하고 있는 추세이다. 따라서 본 연구에서는 정수장에서 최적의 염소주입과 재염소 주입량을 산정하기 위하여 미국 EPA에서 개발한 EPANET 2.0을 사용하여 최적 염소 주입량을 산정하고 그 효과를 모의하였다. 대상지역 상수관로에 대한 수질을 모의하기 위하여 bottle test를 통해 수체감소계수($k_{bulk}$)를 도출하였으며, syster-matic analysis method를 이용하여 관벽감소계수($k_{wall}$)를 도출하였다. 배ㆍ급수계통에서의 수질을 정확히 예측하고자 유량과 체류시간 등을 고려한 수리해석 모델을 기초로 하여 상수도관망에서의 잔류염소 농도를 예측하고 염소주입 농도에 따른 소독부산물(DBPs)인 트리할로메탄(Trihalomethanes; THMs)의 생성변화를 실험을 통해 확인하였다. 수체감소계수($k_{bulk}$)를 도출한 결과 온도가 높을수록 초기에 빠른 감소를 보였으며, $25^{\circ}C$의 경우 25시간이 지난 이후에는 절반이상이 감소하였다. 대상지역에 재염소 주입시설을 도입할 경우 최적 재염소 주입량을 산정하였으며, 관망도상에서 경제적으로 유리한 지점을 선정할 수 있었다.

In general water treatment process, the disinfection process by chlorine is used to prevent water borne disease and microbial regrowth in water distribution system. Because chlorines were reacted with organic matter, carcinogens such as disinfection by-products (DBPs) were produced in drinking water. Therefore, a suitable injection of chlorine is need to decrease DBPs. Rechlorination in water pipelines or reservoirs are recently increased to secure the residual chlorine in the end of water pipelines. EPANET 2.0 developed by the U.S. Environmental Protection Agency (EPA) is used to compute the optimal chlorine injection in water treatment plant and to predict the dosage of rechlorination into water distribution system. The bulk decay constant ($k_{bulk}$) was drawn by bottle test and the wall decay constant ($k_{wall}$) was derived from using systermatic analysis method for water quality modeling in target region. In order to predict water quality based on hydraulic analysis model, residual chlorine concentration was forecasted in water distribution system. The formation of DBPs such as trihalomethanes (THMs) was verified with chlorine dosage in lab-scale test. The bulk decay constant ($k_{bulk}$) was rapidly decreased with increasing temperature in the early time. In the case of 25 degrees celsius, the bulk decay constant ($k_{bulk}$) decreased over half after 25 hours later. In this study, there were able to calculate about optimal rechlorine dosage and select on profitable sites in the network map.

키워드

참고문헌

  1. 손희종, 정철우, 강임석, "상수원수중의 천연유기물질 특성과 염소 소독부산물 생성의 관계," 대한환경공학회지, 26(4), 457-466(2004).
  2. 안재찬, 이수원, 노방식, 최영준, 최재호, 김효일, 박태준, 박창민, 박현, 구자용, "배급수계통에서 잔류염소 및 THMs 분포 예측에 관한 연구," 대한환경공학회지, 29(6), 706-714 (2007).
  3. 환경부, "수도시설의청소및위생관리등에의한규칙", (2009).
  4. Clark, R. M., Rossman, L. A. and Wymer, L. J., "Modeling distribution system water water quality: Regualatory implications," J. Water Res. Plng, and Mgt. ASCE, 121(6), 423-428(1995). https://doi.org/10.1061/(ASCE)0733-9496(1995)121:6(423)
  5. Boccelli, D. L., Tryby, M. E., Uber, J. G. and Summers, R. S., "A reactive species model for chlorine decay and THM formation under rechlorination conditions," Water Res., 37(11), 2654-2666(2003). https://doi.org/10.1016/S0043-1354(03)00067-8
  6. Clark, R. M., Yang, Y. J., Impellitteri, C. A., Haught, R. C., Schupp, D. A., Panguluri, S. and Krishnan, E. R., "Chlorine fate and transport in distribution systems: Experimental and modeling studies," J. AWWA, 102(5), 144-155(2010).
  7. Trehy, M. L. and Bieber, T. I., "Detection, identification, and quantitative analysis of dihaloacetonitriles in chlorinated natural waters," in Advances in the identification and analysis of organic pollutants in water, vol. 2, L. H. Keith, Ed., Ann Arbor, MI: Ann Arbor Science Publishers, Inc., 941-975(1981).
  8. Rossman, L. A., Brown, R. A., Singer, P. C. and Nuckols, J. R., "DBP formation kinetics in a simulated distribution system," Water Res., 35(14), 3483-3489(2001). https://doi.org/10.1016/S0043-1354(01)00059-8
  9. Craun, G. F., Craun, M. F., Calderon, R. L. and Beach, M. J., "Waterborne outbreaks reported in the United States," J. Water and Health, 4(2), 19-30(2006). https://doi.org/10.2166/wh.2006.016
  10. Kim, J. S., Chung Y., Shin D. C., Kim M. S., Lee Y. H., Lim Y. W. and Lee D. H., "Chlorination by-products in surface water treatment process," Desalination, 151(1), 1-9 (2003). https://doi.org/10.1016/S0011-9164(02)00967-0
  11. 이종민, "재염소주입에 따른 관망내 잔류염소 및 트리할로메탄의 거동에 관한 연구," 국민대학교 석사학위논문 (2004).
  12. 환경부, "상수도시설기준", (2004).
  13. 윤재홍, 오정우, 최영송, "배수관망의 잔류염소 평활화를 위한 최적 재염소 처리," 대한상하수도학회지, 12(2), 90-98 (1998).
  14. 정창호, "배수관망에서 잔류염소 제어 및 소독부산물 예측기법 개발," 국민대학교 석사학위논문(2008).
  15. Rossman, L. A., "EPANET 2 User Manual," National risk management research laboratory, Office of research and development, U.S. Environmental Protection Agency, Cincinnati, OH(2000).
  16. Biswas, P., Lu, C. S. and Clark, R. M., "A model for chlorine concentration decay in pipes," Water Res., 27(12), 1715- 1724(1993). https://doi.org/10.1016/0043-1354(93)90108-T
  17. Powell, J. C., Hallam, N. B., West, J. R., Forster, C. F. and Simms, J., "Factors which control bulk chlorine decay rates," Water Res., 34(1), 117-126(2000). https://doi.org/10.1016/S0043-1354(99)00097-4
  18. Rossman, L. A., Clark, R. M. and Grayman, W. M., "Modeling chlorine residuals in drinking-water distribution systems," J. Environ. Eng., 120(4), 803-820(1994). https://doi.org/10.1061/(ASCE)0733-9372(1994)120:4(803)
  19. Vasconcelos, J. J., "Characterization and modeling of chlorine decay in distribution systems," American Water Works Association Research Foundation(1996).
  20. Notter, R. H. and Sleicher, C. A., "The eddy diffusivity in the turbulent boundary layer near a wall?," Chem. Eng. Sci., 26, 161-171(1971). https://doi.org/10.1016/0009-2509(71)86088-8
  21. Mays, L. W., "Water distribution systems handbook," McGraw-Hill(2000).
  22. U.S. Environmental Protection Agency, "Water distribution system analysis: Field studies, modeling and management, Office of research and development, National risk management research laboratory, Water supply and water resources division, Cincinnati, OH(2005).
  23. 이동석, 민병섭, 박선구, 김정화, 류재근, "정수장에서 소독 부산물의 생성특성," 한국물환경학회지, 20(1), 55-62(2004).