An Experimental Study on the Fire Resistance Capacity of Asymmetric Slimflor Beam

비대칭 H형강 슬림플로어 보의 내화 성능에 관한 실험적 연구

  • Published : 2010.02.28

Abstract

Asymmetric Slimflor Beam had been unveiled with Thor beam (Hat beam) in Sweden since the late 1970s and had been developed by British Steen and SCI. In the major advanced countries in Europe after the early 1990s have interested in and developed this method, it has been concrened as the absence of hot-rolled section steel in the United Kingdom and welded of asymmetric section steel in Finland in the 2000s. It can be increase total floor area about 10%, save the interior and exterior materials, reduce the waste through reduction of the floor height. And it has more excellent fire resistance performance because less exposed than a regular composite steel beam in fire. This study is purpose that, a fire resistance performance of the Asymmetric Slimflor Beam in fire, it compared the temperature range with deflection of structure by fire behavior and load ratio of structure through change the shape of the steel cross-section in standard fire condition.

비대칭 H형강을 활용한 합성보는 1970년대 후반 이후 스웨덴에서 Thor beam(Hat beam)으로 발표되었으며 British Steel과 SCI는 슬림플로어 보를 개발하였다. 슬림플로어 공법은 1990년대 초반부터 유럽의 주요 선진국에서 많은 관심을 갖고 개발하여 온 건축 구조 부재의 한 형태로 2000년대에 영국에서는 열간압연 형강 그리고 핀란드에서는 비대칭 용접 형강의 관심이 집중되고 있다. 슬림플로어 공법의 가장 큰 장점은 층고 감소를 토대로 도심 건축물의 최대 10% 내외의 연면적 증가 효과와 각종 내 외장재 절감 및 자원의 절약 폐기물 감소효과 등이며 일반 합성보에 비하여 철골보의 노출면이 적어 내화 성능에서도 우수한 장점이 있다. 본 연구는 비대칭 H형강을 사용한 슬림플로어 보의 화재시 구조 성능에 관한 연구로 표준화재조건에서 강재 단면의 형상 변화를 통한 구조물의 내화 거동과 재하 하중비를 변수로 화재시 구조물의 온도 분포와 처짐을 비교 분석하는 것을 목적으로 한다.

Keywords

References

  1. D.L. Mullett, "Composite Floor Systems", pp.112- 118, Blackwell Science, UK(1998).
  2. Pentti Makelainen and Zhongcheng Ma, "Fire Resistance of Composite Slim Floor Beams", Journal of Constructional Steel Research, Vol.54, pp.345- 363(2000). https://doi.org/10.1016/S0143-974X(99)00059-0
  3. Zhongcheng Ma and Pentti Makelainen, "Structural behavior of Composite Slim Floor Frames in Fire Conditions", Journal of Constructional Steel Research, Vol.62, pp.1282-1289(2006). https://doi.org/10.1016/j.jcsr.2006.04.026
  4. G.M. Newman, "Fire Resistance of Slim Floor Beams", Journal of Constructional Steel Research, Vol.33, pp.87-100(1995). https://doi.org/10.1016/0143-974X(94)00016-B
  5. C.G. Bailey, "The behavior of Asymmetric Slim Floor Steel Beams in Fire", Journal of Constructional Steel Research, Vol.50, pp.235-257(1999). https://doi.org/10.1016/S0143-974X(98)00247-8
  6. 한상훈, 최승관, 김희주, "비대칭 H형강을 사용한 슬 림플로어 보의 내화성능에 관한 연구", 한국강구조학회 논문집, Vol.19, No.4, pp.357-366(2007).
  7. 박원섭, 최승관, 한상훈, 이철호, 김정현, "비대칭 슬 림플로어 합성보의 내화성능에 관한 실험적 연구", 한국강구조학회 학술대회논문집, pp.469-472(2008).
  8. KS F 2257-6: 2006, "건축부재의 내화 시험 방법 - 보의 성능 조건", 한국산업규격.