DOI QR코드

DOI QR Code

Phosphorus Removal (Characteristics by Anoxic Oxic Process) by Anoxic and Oxic Processed Combined with Iron Electrolysis

철 석출장치가 결합된 무산소.호기공정에 의한 인 제거 특성

  • Kim, Min-Ho (Department of Health and Environment, Kook Je College) ;
  • Kim, Young-Gyu (Department of Environmental Science, Yong In University) ;
  • Kim, Soo-Bok (Institute of Natural Science, Yong In University)
  • Received : 2010.09.08
  • Accepted : 2010.12.09
  • Published : 2010.12.30

Abstract

In this study, the (phosphorous removal) the characteristics of phosphorous removal due to (the iron compound precipitated) iron compound precipitation by iron electrolysis in (the anoxic. oxic process) anoxic and oxic processes (equipped with the) in an iron precipitation device were analyzed. During the device operation period, the average concentration of BOD, T-N, and T-P were 219.9 mg/l, 54.6 mg/l and 6.71 mg/l, respectively. The BOD/$COD_{Cr}$ ratio was 0.74, and the BOD/T-N and BOD/T-P ratios were 4.0 and 32.8, respectively. The removal rate of (the organic matters) organic matter (BOD and $COD_{Cr}$) was very high at 91.6% or higher, and that of nitrogen was 80.5%. The phosphorous concentration (of the final) in the treated water was 0.43 mg/l (0.05-0.74 mg/l) on average, and the removal efficiency was high at 90.8%. The soluble T-P concentrations in (an) the anoxic reactor, oxic reactor (II) and final treated water were 1.99 mg/l, 0.79 mg/l and 0.43 mg/l, respectively, which indicated that the phosphorous concentration in the treated water was very low. Regardless of the changes in the concentrations of (organic matters) organic matter, nitrogen and phosphorous in the influent, the quality of the treated water was relatively stable and high. The removal rate of T-P somewhat increased with the increase in the F/M ratio in the influent, and it also linearly increased in proportion to the T-P loading rate in the influent. In the treatment process used in this study, phosphorous was removed (using) by the precipitated iron oxide. Therefore, the consumption of organic (matters) matter for biological phosphorus removal was minimized and (most of the organic matters were) was mostly used as the organic carbon source for the denitrification in the anoxic reactor. This (can be an economic) treatment process (without the need for the supply of additional organic matters) is economic and does not require the supply of additional organic matter.

Keywords

References

  1. Cho, I. H., Zoh, K. D., An, S. W., Chang, S. W. and Kim, Y. G. : Characterization of phosphorus removal in wastewater using iron precipitation reactor. Korean Journal of Environmental Health Science, 32(1), 89-95, 2006.
  2. U.S. EPA : Process Design Manual for Phosphorus Control. 1987.
  3. Envinet. Co. Ltd., Gakuyng Cosmo, Daejin Environment : Phosphorus Removal by Anoxic ..Oxic Pilot-Plant adding ferrous compound by Iron Electrolysis. 2009.
  4. James, B. R., Rabenhorst, M. C. and Frogen, G. A : Phosphorus sorption by peat and sand amended with iron oxiders or steel wool. Water Environment Research, 64(5), 699-705, 1967.
  5. Gangol, N. and Thodos, G. : Phosphate adsorption studies. Water Environment Research, 45(5), 842-849, 1973.
  6. Kavanaugh, M. C., Krejci, V., Weber, T., Eugster, J. and Roberts, P. V. : Phosphorus removal by postprecipitation with Fe(III). Water Environment Research, 50, 216-233, 1978.
  7. Groterud O. and Smoczynski, L. : Phosphorus removal from water by means of electrolysis. Water Research, 20(5), 667-669, 1986. https://doi.org/10.1016/0043-1354(86)90032-1
  8. Environmental Protection Agency, Water Standard Method of Korea, 2008.
  9. APHA-AWWA-WPCF : Standard methods for the examination of water and wastewater. American Public Health Association, 2002.
  10. Bard, A. T. : Encyclopedia of electrochemistry of the elements. New York and Basel, 4, 230-360, 1982.
  11. NIER, HRERC : Feasibility study on the application of physicochemical process for phosphorous removal in environmental facilities located in upper reaches of the watershed lake. GOVP1200947842, 160-169, 2009.
  12. Rabinowitz, B., Vassos, T. D., Dawsom, R. N. and Oldham, W. K. : Upgrading wastewater treatment plants for biological nutrient removal. Water Science Technology, 22(7/8), 53-60, 1990.
  13. Nicholls, H. A., Pitman, A. R. and Osborn, D. W. : The readily biodegradable fraction of sewage ; its influnence of phosphorus removal and measurement. Water Science Technology, 17, 73-87, 1985.
  14. EPA : Phosphorus Removal Design Manual,Environmtal Protection Agency, 1-87, 1987.
  15. Goncalves, R. F., Charlier, A. C. and Sammut, F. : Primary fermentation of soluble and particulate organic matter for wastewater treatment. Water Science Technology, 30(6), 53-62, 1994.
  16. Ryu, H. D., Min, K. K., Lee, J. H., Choi, K. Y., Lim, H. E., Kim, C. H. and Lee, S. I. : Development of BNR(Biological Nutrient Removal) process using Expanded Polystylene (EPS) media. Journal of Korean Society of Environmental Engineers, 28(1), 1-6, 2006.

Cited by

  1. A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process vol.39, pp.1, 2013, https://doi.org/10.5668/JEHS.2013.39.1.83