참고문헌
- Agrawal, A.K. and Yang, J.N. (1999), "Design of passive energy dissipation systems based on LQR control methods", J. Intel. Mat. Syst. Str., 10(12), 933-944. https://doi.org/10.1106/FB58-N1DG-ECJT-B8H4
- Agrawal, A.K. and Yang, J.N. (1999), "Optimal placement of passive dampers on seismic and wind-excited buildings using combinatorial optimization", J. Intel. Mat. Syst. Str., 10(12), 997-1014. https://doi.org/10.1106/YV3B-TP5H-HWQ2-X1OK
- Attard, T.L. (2007). "Controlling all interstory displacements in highly nonlinear steel buildings using optimal viscous damping", J. Struct. Eng., 133(9), 1331-1340. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:9(1331)
- Aydin, E., Boduroglu, M.H. and Guney, D. (2007), "Optimal damper distribution for seismic rehabilitation of planar building structures", Eng. Struct., 29, 176-185. https://doi.org/10.1016/j.engstruct.2006.04.016
- Christopoulos, C. and Filiatrault, A. (2006), Principles of supplemental damping and seismic isolation, Milan, Italy, IUSS Press.
- Constantinou, M.C. and Tadjbakhsh, I.G. (1983), "Optimum design of a first story damping system", Comput. Struct., 17(2), 305-310. https://doi.org/10.1016/0045-7949(83)90019-6
- Dargush, G.F. and Sant, R.S. (2005), "Evolutionary aseismic design and retrofit of structures with passive energy dissipation", Earthq. Eng. Struct. Dyn., 34, 1601-1626. https://doi.org/10.1002/eqe.497
- fujita, k., moustafa, a. and takewaki, i. (2010), optimal placement of viscoelastic dampers and supporting members under variable critical excitations. Earthq. Struct., 1(1), 43-67. https://doi.org/10.12989/eas.2010.1.1.043
- Gluck, N., Reinhorn, A.M., Gluck, J. and Levy, R. (1996), "Design of supplemental dampers for control of structures", J. Struct. Eng. - ASCE, 122(12), 1394-1399. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:12(1394)
- Hahn, G.D. and Sathiavageeswaran, K.R. (1992), "Effects of added-damper distribution on the seismic response of buildings", Comput. Struct., 43(5), 941-950. https://doi.org/10.1016/0045-7949(92)90308-M
- Hwang, J.S. and Huang, Y.N. et al. (2008), "Design formulations for supplemental viscous dampers to building structures", J. Struct. Eng., 134(1), 22-31. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(22)
- Kim, J. and Bang, S. (2002), "Optimum distribution of added viscoelastic dampers for mitigation of torsional responses of plan-wise asymmetric structures", Eng. Struct., 24(10), 1257-1269. https://doi.org/10.1016/S0141-0296(02)00046-9
- Kim, J., Choi, H. and Min, K.W. (2003), "Performance-based design of added viscous dampers using capacity spectrum method", J. Earthq. Eng., 7(1), 1-24.
- Lavan, O., Cimellaro, G.P. and Reinhorn, A.M. (2008), "Noniterative optimization procedure for seismic weakening and damping of inelastic structures", J. Struct. Eng., 134(10), 1638-1648. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:10(1638)
- Lavan, O. and Dargush, G.F. (2009), "Multi-objective optimal seismic retrofitting of structures", J. Earthq. Eng., 13, 758-790. https://doi.org/10.1080/13632460802598545
- Lavan, O. and Levy, R. (2005), "Optimal design of supplemental viscous dampers for irregular shear-frames in the presence of yielding", Earthq. Eng. Struct. Dyn., 34, 889-907. https://doi.org/10.1002/eqe.458
- Lavan, O. and Levy, R. (2006a), "Optimal design of supplemental viscous dampers for linear framed structures", Earthq. Eng. Struct. Dyn., 35, 337-356. https://doi.org/10.1002/eqe.524
- Lavan, O. and Levy, R. (2006b), "Optimal peripheral drift control of 3D irregular framed structures using supplemental viscous dampers", J. Earthq. Eng., 10(6), 903-923.
- Lavan, O. and Levy, R. (2009), "Simple iterative use of Lyapunov's solution for the linear optimal seismic design of passive devices in framed buildings", J. Earthq. Eng., 13(5), 650-666. https://doi.org/10.1080/13632460902837736
- Levy, R. and Lavan, O. (2006), "Fully stressed design of passive controllers in framed structures for seismic loadings", J. Struct. Multidiscip. O., 32(6), 485-498. https://doi.org/10.1007/s00158-005-0558-5
- Levy, R. and Lavan, O. (2009), "Quantitative comparison of optimization approaches for the design of supplemental damping in earthquake engineering practice", J. Struct. Eng., 135(3), 321-325. https://doi.org/10.1061/(ASCE)0733-9445(2009)135:3(321)
- Lin, Y.Y., Chang, K.C. and Chen, C.Y. (2008), "Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers", Bull. Earthq. Eng., 6, 535-552. https://doi.org/10.1007/s10518-008-9062-9
- Liu, W., Tong, M. and Lee, G.C. (2005), "Optimization methodology for damper configuration based on building performance indices", J. Struct. Eng., 131(11), 1746-1756. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:11(1746)
- Liu, W., Tong, M., Wu. Y. and Lee, G.C. (2004), "Optimized damping device configuration design of a steel frame structure based on building performance indices", Earthq. Spectra, 20(1), 67-89. https://doi.org/10.1193/1.1648334
- Loh, C.H., Lin, P.Y. and Chung, N.H. (2000), "Design of dampers for structures based on optimal control theory", Earthq. Eng. Struct. Dyn., 29(9), 1307-1323. https://doi.org/10.1002/1096-9845(200009)29:9<1307::AID-EQE972>3.0.CO;2-D
- Lopez-Garcia, D. (2001) "A simple method for the design of optimal damper configurations in MDOF structures", Earthq. Spectra, 17(3), 387-398. https://doi.org/10.1193/1.1586180
- Ozdemir, H. (1976), Nonlinear transient dynamic analysis of yielding structures, Ph. D. dissertation, University of California, Berkeley.
- Park, Y.J. and Ang, A.H.S. (1985), "Mechanistic seismic damage model for reinforced concrete", J. Struct. Eng., 111(4), 722-739. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:4(722)
- Park, J.H. kim, J. and Min, K.W. (2004), "Optimal design of added viscoelastic dampers and supporting braces", Earthq. Eng. Struct. Dyn., 33, 465-484. https://doi.org/10.1002/eqe.359
- Shen, K.L. and Soong, T.T. (1996), "Design of energy dissipation devices based on concept of damage control", J. Struct. Eng. - ASCE, 122(1), 76-82. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:1(76)
- Shukla, A.K. and Datta, T.K. (1999), "Optimal use of viscoelastic dampers in building frames for seismic force", J. Struct. Eng. - ASCE, 125(4), 401-409. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:4(401)
- Silvestri, S. and Trombetti, T. (2007), "Physical and numerical approaches for the optimal insertion of seismic viscous dampers in shear-type structures", J. Earthq. Eng., 11(5), 787-828. https://doi.org/10.1080/13632460601034155
- Silvestri, S., Trombetti, T. and Ceccoli, C. (2003), "Inserting the mass proportional damping (MPD) system in a concrete shear-type structure", Struct. Eng. Mech., 16(2), 177-193. https://doi.org/10.12989/sem.2003.16.2.177
- Singh, M.P. and Moreschi, L.M. (2001), "Optimal seismic response control with dampers", Earthq. Eng. Struct. Dyn., 30(4), 553-572. https://doi.org/10.1002/eqe.23
- Singh, M.P. and Moreschi, L.M. (2002), "Optimal placement of dampers for passive response control", Earthq. Eng. Struct. Dyn., 31(4), 955-976. https://doi.org/10.1002/eqe.132
- Singh, M.P. Verma, N.P. and Moreschi, L.M. (2003), "Seismic analysis and design with Maxwell dampers", J. Eng. Mech., 129(3), 273-282. https://doi.org/10.1061/(ASCE)0733-9399(2003)129:3(273)
- Sivaselvan, M.V. and Reinhorn, A.M. (2000), "Hysteretic models for deteriorating structures", J. Eng. Mech. - ASCE, 126, 633-640. https://doi.org/10.1061/(ASCE)0733-9399(2000)126:6(633)
- Somerville, P., Smith, N., Punyamurthula, S. and Sun, J. (1997), "Development of ground motion time histories for Phase 2 of the FEMA/SAC steel project", Report No. SAC/BD-97/04. The ground motions can be downloaded from: "http://quiver.eerc.berkeley.edu:8080/studies/system/ground_motions.html".
- Soong, T.T. (1990), Active structural control, Longman Scientific & Technical, Harlow, England.
- Soong, T.T and Dargush, G.F. (1997), Passive energy dissipation systems in structural engineering, John Wiley & Sons Ltd., Chichester.
- Takewaki, I. (1997), "Optimal damper placement for minimum transfer function", Earthq. Eng. Struct. Dyn., 26(11), 1113-1124. https://doi.org/10.1002/(SICI)1096-9845(199711)26:11<1113::AID-EQE696>3.0.CO;2-X
- Takewaki, I. (2000), "Optimal damper placement for critical excitation", Probabilist. Eng. Mech., 15(4), 317-325. https://doi.org/10.1016/S0266-8920(99)00033-8
- Takewaki, I. (2000), "Optimal damper placement for planar building frames using transfer functions", Struct. Multidiscip. O., 20(4), 280-287. https://doi.org/10.1007/s001580050158
- Takewaki, I. and Uetani, K. (1999), "Optimal damper placement for building structures including surface ground amplification", Soil Dyn. Earthq. Eng., 18(5), 363-371. https://doi.org/10.1016/S0267-7261(99)00007-X
- Takewaki, I. Yoshitomi, S. Uetani, K. and Tsuji, M (1999), "Non-monotonic optimal damper placement via steepest direction search", Earthq. Eng. Struct. Dyn., 28(6), 655-670. https://doi.org/10.1002/(SICI)1096-9845(199906)28:6<655::AID-EQE833>3.0.CO;2-T
- Takewaki, I. (2009), Building control with passive dampers: optimal performance-based design for earthquakes, John Wiley & Sons Ltd. (Asia), Singapore.
- Trombetti, T. and Silvestri, S. (2004), "Added viscous dampers in shear-type structures: the effectiveness of mass proportional damping", J. Earthq. Eng., 8(2), 275-313.
- Trombetti, T. and Silvestri, S. (2006), "On the modal damping ratios of shear-type structures equipped with Rayleigh damping systems", J. Sound Vib., 292, 21-58. https://doi.org/10.1016/j.jsv.2005.07.023
- Trombetti, T. and Silvestri, S. (2007), "Novel schemes for inserting seismic dampers in shear-type systems based upon the mass proportional component of the Rayleigh damping matrix", J. Sound. Vib., 302(3), 486-526. https://doi.org/10.1016/j.jsv.2006.11.030
- Uang, C.M. and Bertero, V.V. (1990), "Evaluation of seismic energy in structures", Earthq. Eng. Struct. Dyn., 19(1), 77-90. https://doi.org/10.1002/eqe.4290190108
- Uriz, P, and Whittaker, A.S. (2001), "Retrofit of pre-Northridge steel moment-resisting frames using fluid viscous dampers", Struct. Design Tall Build., 10, 371-390. https://doi.org/10.1002/tal.199
- Valmundsson, V.E. and Nau, J.M. (1997), "Seismic response of building frames with vertical structural irregularities", J. Struct. Eng. - ASCE, 123(12), 30-41. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:1(30)
- Yang, J.N., Lin, S., Kim, J.H. and Agrawal, A.K. (2002), "Optimal design of passive energy dissipation systems based on H infinity and H2 performances", Earthq. Eng. Struct. Dyn., 31(4), 921-936. https://doi.org/10.1002/eqe.130
- Zhang, R.H. and Soong, T.T. (1992), "Seismic design of viscoelastic dampers for structural applications", J. Struct. Eng. - ASCE, 118(5), 1375-13 https://doi.org/10.1061/(ASCE)0733-9445(1992)118:5(1375)
피인용 문헌
- A simple damper optimization algorithm for both target added damping ratio and interstorey drift ratio vol.5, pp.1, 2013, https://doi.org/10.12989/eas.2013.5.1.083
- Optimality criteria based seismic design of multiple tuned-mass-dampers for the control of 3D irregular buildings vol.8, pp.1, 2015, https://doi.org/10.12989/eas.2015.8.1.077
- Using an artificial bee colony algorithm for the optimal placement of viscous dampers in planar building frames vol.48, pp.2, 2013, https://doi.org/10.1007/s00158-013-0892-y
- Seismic retrofit of special truss moment frames using viscous dampers vol.123, 2016, https://doi.org/10.1016/j.jcsr.2016.04.027
- Adjoint sensitivity analysis and optimization of hysteretic dynamic systems with nonlinear viscous dampers 2017, https://doi.org/10.1007/s00158-017-1858-2
- Comparative experimental assessment of seismic rehabilitation with CFRP strips and sheets on RC frames vol.10, pp.3, 2016, https://doi.org/10.12989/eas.2016.10.3.613
- Simultaneous optimal damper placement using oil, hysteretic and inertial mass dampers vol.5, pp.3, 2013, https://doi.org/10.12989/eas.2013.5.3.261
- Gradient based optimal seismic retrofitting of 3D irregular buildings using multiple tuned mass dampers vol.139, 2014, https://doi.org/10.1016/j.compstruc.2014.03.002
- Optimal Design of Viscous Dampers and Their Supporting Members for the Seismic Retrofitting of 3D Irregular Frame Structures vol.141, pp.11, 2015, https://doi.org/10.1061/(ASCE)ST.1943-541X.0001261
- Seismic response of active or semi active control for irregular buildings based on eigenvalues modification vol.6, pp.6, 2014, https://doi.org/10.12989/eas.2014.6.6.647
- Efficient Seismic Design of 3D Asymmetric and Setback RC Frame Buildings for Drift and Strain Limitation vol.143, pp.4, 2017, https://doi.org/10.1061/(ASCE)ST.1943-541X.0001689
- Optimization-based minimum-cost seismic retrofitting of hysteretic frames with nonlinear fluid viscous dampers vol.47, pp.15, 2018, https://doi.org/10.1002/eqe.3118
- Free vibration analysis of tall buildings with outrigger-belt truss system vol.2, pp.1, 2011, https://doi.org/10.12989/eas.2011.2.1.089
- Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frames vol.39, pp.4, 2010, https://doi.org/10.12989/sem.2011.39.4.499
- Seismic design of a precast r.c. structure equipped with viscous dampers vol.2, pp.3, 2011, https://doi.org/10.12989/eas.2011.2.3.297
- Seismic evaluation and upgrading of RC buildings with weak open ground stories vol.3, pp.3, 2010, https://doi.org/10.12989/eas.2012.3.3_4.611
- Numerical verification of a dual system's seismic response vol.3, pp.5, 2010, https://doi.org/10.12989/eas.2012.3.5.749
- A simplified design procedure for seismic retrofit of earthquake-damaged RC frames with viscous dampers vol.44, pp.5, 2010, https://doi.org/10.12989/sem.2012.44.5.611
- A retrofitting method for torsionally sensitive buildings using evolutionary algorithms vol.12, pp.3, 2017, https://doi.org/10.12989/eas.2017.12.3.309
- Zemin-yapı etkileşiminin betonarme bacaların dinamik davranışına etkisi vol.7, pp.1, 2010, https://doi.org/10.29130/dubited.465732
- Hysteretic-Viscous Hybrid Damper System for Long-Period Pulse-Type Earthquake Ground Motions of Large Amplitude vol.6, pp.None, 2020, https://doi.org/10.3389/fbuil.2020.00062
- Multi-criteria performance-based optimization of friction energy dissipation devices in RC frames vol.18, pp.2, 2010, https://doi.org/10.12989/eas.2020.18.2.185
- Comparison of different distributions of viscous damper properties in asymmetric-plan frames vol.18, pp.2, 2020, https://doi.org/10.12989/eas.2020.18.2.233
- DEM Simulations of Energy Dissipation in Sand under Static and Cyclic Loading vol.49, pp.1, 2021, https://doi.org/10.1520/jte20190829
- Comprehensive Review of Optimal and Smart Design of Nonlinear Building Structures With and Without Passive Dampers Subjected to Earthquake Loading vol.7, pp.None, 2010, https://doi.org/10.3389/fbuil.2021.631114
- Optimal Seismic Design of Stiffness and Gap of Hysteretic-Viscous Hybrid Damper System in Nonlinear Building Frames for Simultaneous Reduction of Interstory Drift and Acceleration vol.7, pp.None, 2010, https://doi.org/10.3389/fbuil.2021.656606
- Inverse optimal damper placement via shear model for elastic-plastic moment-resisting frames under large-amplitude ground motions vol.250, pp.None, 2010, https://doi.org/10.1016/j.engstruct.2021.113457