DOI QR코드

DOI QR Code

Development of the Contingency Analysis Program of Korean Energy Management System

한국형 에너지 관리시스템용 상정고장 해석프로그램 개발

  • Published : 2010.02.01

Abstract

This paper describes the development of robust contingency analysis program for Korean Energy Management System. The important function of contingency analysis is to determine the bus/branch model for contingency, and to calculate the state of the power network based on the network model and topology output. In the proposed method, the bus/branch models for contingencies are determined exactly using a fast linked-list method based on the application common model database. To calculate the state of the power system included contingency, the full-decoupled powerflow approach, the partial powerflow method for contingencies and the proposed contingency screening algorithm are also used to contingency analysis. To verify the performance of the developed processor, we performed a file-based test using several structured input data and online test using the database which resides on memory. The results of these comprehensive tests showed that the developed processors can accurately calculate the power system contingency state from online data and can be applied to Korea Power Exchange system.

Keywords

References

  1. F. F. Wu, K. Moslehi, and A. Bose, "Power system control center: Past, Present, and Future," Proc. IEEE, vol. 93, no. 11, pp. 1890-1908, Nov. 2005. https://doi.org/10.1109/JPROC.2005.857499
  2. R. Qiantu, H. Guangyu, M. Shengwei, and L. Qiang, "Advanced EMS and its application to shanghai power grid," in Proc. IEEE Int. Conf. Electro/Information Technology, Chicago, IL, May. 2007, pp. 312-317.
  3. Y. Liao, "Interface paradigms in energy management system," in Proc. IEEE Southeastcon, Huntsville, Alabama, Apr. 2008, pp. 485-490.
  4. F. Maghsoodlou, R. Masiello, and T. Ray, "Energy management systems," IEEE Power Energy, vol. 2, no. 5, pp. 49-57, Sep/Oct. 2004.
  5. G. C. Ejebe, B. F. Wollenberg, "Automatic Contingency Selection", IEEE Trans. Power App. Syst., vol PAS-98, no. 1, pp. 97-109, Jan./Feb. 1979. https://doi.org/10.1109/TPAS.1979.319518
  6. G. D. Irisarri, A. M. Sasson, "An Automatic Contingency Selection Method for On-line Security Analysis", IEEE Trans. Power App. Syst., vol PAS-100, no. 4, pp. 1838-1844, Apr. 1981. https://doi.org/10.1109/TPAS.1981.316524
  7. M. K. Enns, J. J. Quada, B. Sackett, "Fast Linear Contingency Analysis", IEEE Trans. Power App. Syst., vol PAS-101, no. 4, pp. 783-791, Apr. 1982. https://doi.org/10.1109/TPAS.1982.317142
  8. S. Vemuri, R. E. Usher, "On-line Automatic Contingency Algorithm", IEEE Trans. Power App. Syst., vol PAS-102, no. 2, pp. 346-354, Feb. 1983. https://doi.org/10.1109/TPAS.1983.317681
  9. I. Dabbaghchi, G. D. Irisarri, "AEP Automatic Contingency Selector: Branch Outage Impacts on Load Bus Voltage Profile", IEEE Trans. Power Syst., vol PWRS-1, no. 2, pp. 37-44, May 1986.
  10. W. F. Tinney, J. W. Walker, "Direct Solutions of Sparse Network Equations by Optimally Ordered Triangular Factorization", Proc IEEE, Vol. 55, no. 11, pp. 1801-1809, Nov. 1967. https://doi.org/10.1109/PROC.1967.6011
  11. W. F. Tinney, W. S. Meyer, "Solution of Large Sparse Systems by Ordered Triangular Factorization", IEEE Trans. Automat. Contr., Vol. 18, no. 4, pp. 333–346, Aug. 1973.