DOI QR코드

DOI QR Code

On-line Faults Signature Monitoring Tool for Induction Motor Diagnosis

  • Published : 2010.03.01

Abstract

The monitoring and the diagnosis of the faults in induction motors starting from the stator current are very interesting, since it is an accessible and measurable quantity. The spectral analysis of the stator current makes it possible to highlight the characteristic frequencies of the faults but in a wide frequency range depending on half the sampling frequency, making it very difficult to monitor on-line the faults. In order to facilitate the use of the relevant frequencies of machine faults we proposed the extraction of the frequency components using two methods, namely, the amplitude and the instantaneous frequency. The theoretical bases of these methods were presented and the results were validated on a test bench with an induction motor of 5.5 kw.

Keywords

References

  1. G.B. Kilman and J. Stein. Methods of motor current signature analysis. Electr. Mach. & Power Syst, Vol.5, No. 1, pp.41-52, 1999.
  2. A.J.M. Cardoso, S.M.A. Cruz, J.F.S. Carvalho, and E.S. Saraiva. Rotor cage fault diagnosis in induction motors by park's vector approach. IEEE, IAS'95 Orlando, Florida, Oct., pp642-646, 1995.
  3. Lebaroud Abdesselam, Clerc Guy, "Classification of Induction Machine Faults by Optimal Time-Frequency Representations," Industrial Electronics, IEEE Transactions, pp.4290- 4298, Vol.55, No.12, Dec., 2008. https://doi.org/10.1109/TIE.2008.2004666
  4. Thomson W. T., M Fenger "Current signature analysis to detect inductions motor faults " Introduction" IEEE Industry Applications Magazine_ July/August 2001. https://doi.org/10.1109/2943.930988
  5. Lebaroud Abdesselam, Abdelmalek Khezzar, Ammar Bentounsi, Guy Clerc "Comparison of the Induction Motors Stator Fault Monitoring Methods Based on Current Negative Symmetrical Component," European power electronics and drives , EPE Journal, Vol. 17, No.1, Mar., 2007.
  6. Francesco Cupertino et all, "Analysis Techniques for Detection of IM Broken Rotor Bars After Supply Disconnection," IEEE transactions on industry applications, Vol.40, No.2, 2004.
  7. Lebaroud Abdesselam, Clerc Guy "Diagnosis of Induction Motor Faults Using Instantaneous Frequency Signature Analysis, International conference in electrical machines (ICEM'08), Portugal, Sep., 2008.

Cited by

  1. Classification of Induction Machine Faults using Time Frequency Representation and Particle Swarm Optimization vol.9, pp.1, 2014, https://doi.org/10.5370/JEET.2014.9.1.170
  2. Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open vol.9, pp.3, 2014, https://doi.org/10.5370/JEET.2014.9.3.899
  3. Industrial drive fault diagnosis through vibration analysis using wavelet transform vol.23, pp.12, 2017, https://doi.org/10.1177/1077546315606602
  4. A Study on Fast Maximum Efficiency Control of Stator-Flux-oriented Induction Motor Drives vol.6, pp.5, 2011, https://doi.org/10.5370/JEET.2011.6.5.626
  5. Fault diagnosis in yaw drive induction motor for wind turbine pp.2048-402X, 2018, https://doi.org/10.1177/0309524X18780379