Abstract

In this paper, a fault diagnosis algorithm for brushless DC (BLDC) motor drives is proposed to maintain control performance under switch open-damage. The proposed fault diagnosis algorithm consists of a simple algorithm using measured phase current information and it detects open-circuit faults based on the operating characteristic of BLDC motors. The proposed algorithm quickly recovers control performance due to its short detection time and its reconfiguration of the system topology. It can be embedded into existing BLDC drive software as a subroutine without additional sensors. The feasibility of the proposed fault diagnosis algorithm is proven by simulation and experimental results.

Keywords

References

  1. R. Isermann, "Fault-Diagnosis Systems: An Introduction from Fault Detection to Fault Tolerance," Springer, 2005.
  2. Bin Lu and Santosh Sharma, "A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters," IEEE Trans. on Ind. Appl., vol. 45, no. 5, pp. 1770-1777, Sep./Oct. 2009. https://doi.org/10.1109/TIA.2009.2027535
  3. Tae-Jin Kim, Woo-Chul Lee, and Dong-Seok Hyun, "Detection method for open-circuit fault neutral-point- calmped inverter systems", IEEE Trans. on Industial Electronics, vol. 56, no.7, pp. 2754-2763, July 2009. https://doi.org/10.1109/TIE.2009.2019775
  4. R. Peuget, S. Courtine, and J. P. Rognon, "Fault detection and isolation on a PWM inverter by knowledge-based model," IEEE Trans. Ind. Appl., vol. 34, no. 6, pp. 1318-1326, Nov./Dec. 1998. https://doi.org/10.1109/28.739017
  5. K. Rothenhagen and F. W. Fuchs, "Performance of Diagnosis Methods for IGBT Open Circuit Faults in Voltage Source Active Rectifiers," in Proc. Power Electron. Spec Conf., pp. 4348-4354, 2004.
  6. R. L. A. Ribeiro, C. B. Jacobina, E. R. C. da Silva and A. M. N. Lima, "Fault detection of open-switch damage in voltage-fed PWM motor drive systems," IEEE Trans. Power Electron., vol. 18, no. 2, pp. 587-593, Mar. 2003. https://doi.org/10.1109/TPEL.2003.809351
  7. O. S. Yu, N. J. Park, and D. S. Hyun, "A novel fault detection scheme for voltage fed PWM inverter," in Proc. IEEE Ind. Electron. Conf., pp. 2654–2659, 2006.
  8. M. Awadallah and M. Morcos, "Automatic Diagnosis and Location of Open-Switch Fault in Brushless DC Motor Drives Using Wavelets and Neuro-Fuzzy Systems," IEEE Trans. on Energy Conversion, vol. 21, no. 1, pp.104-111, Mar. 2006. https://doi.org/10.1109/TEC.2004.841502
  9. F. Charfi, F. Sellami, and K. Al-Haddad, "Fault Diagnosis in Power System Using Wavelet Transforms and Neural Networks," in Proc. IEEE Int. Symp. Ind. Electron., pp. 1143–1148, 2006
  10. R. Spee and T. Lipo, "Remedial strategies for brushless dc drive failures," IEEE Trans. Ind. Appl., vol. 26, no. 2, pp. 259-266, Mar./Apr. 1990. https://doi.org/10.1109/28.54251
  11. R. L. A. Ribeiro, C. B. Jacobina and E. R. C. da Silva, "Fault-tolerant voltage-fed PWM inverter AC motor drive systems," IEEE Trans. Ind. Appl., vol. 51, no. 2, pp. 439-446, Apr. 2004.
  12. Byoung-Kuk Lee, Tae-Hyung Kim and M. Ehasani, "On the feasibility of four-switch three-phase BLDC motor drives for low cost commercial applications: topology and control," IEEE Trans. Power Electron., vol. 18, no. 1, pp. 164-172, Jan. 2003. https://doi.org/10.1109/TPEL.2002.807125

Cited by

  1. Open Circuit Fault Diagnosis Using Stator Resistance Variation for Permanent Magnet Synchronous Motor Drives vol.13, pp.6, 2013, https://doi.org/10.6113/JPE.2013.13.6.985
  2. Efficiency Evaluation of Five-Phase Outer-Rotor Fault-Tolerant BLDC Drives under Healthy and Open-Circuit Faulty Conditions vol.14, pp.2, 2014, https://doi.org/10.4316/AECE.2014.02023
  3. A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters vol.16, pp.3, 2016, https://doi.org/10.6113/JPE.2016.16.3.1087