Abstract
In South Korea, mora than 90% of swine barns had open-style side wall by winch operation, and less than 5% of swine barns were semi-windowless or windowless style. The aisle ventilation system of the barn was changed to roof-wall ventilation system, and the width and the length of barns were 10~12 m and 30~50 m, respectively. The width of aisle satisfying energy save was 2~3 m. The re-modeled barns inhaled air through duct which was opened to aisle and exhaled through forced ventilation fans on the windowless wall which was accomplished by installing planks on the open wall. After remodelling, the culling ratio and energy cost were decreased from 11% (47 heads) to 3% (12 heads) and from 1,550,000 won to 730,000 won, respectively. Hence, re-modeled swine barns raising 400 heads could save 2,835,680 won during winter (from December to March).
$\bigcirc$ 현장조사 결과 우리나라 개방식 돈사의 측벽 비율은 윈치시설이 90% 이상이었고, 반무창은 5%였으며 무창 또한 5% 전후로 조사되었다. $\bigcirc$ 리모델링 돈사는 복도덕트로 입기를 하였고 지붕 또는 측벽배기로 하였고 이때 돈사의 폭 10~12 m, 길이 30~50m 전후로 조사되었다. $\bigcirc$ 에너지 절감효과를 위한 복도 설치는 개방식 돈사의 리모델링 개조시 돈사 출입문에 복도 2~3 m (돈사길이 비율 7~8%)를 설치가 양호하였다. $\bigcirc$ 리모델링 돈사의 환기시스템은 복도에서의 덕트를 통한 입기를 실시하고 양쪽 측벽을 판넬 등으로 밀폐화 (무창)를 하고 측벽배기를 하였다. $\bigcirc$ 폐사율 저감은 개선전 11% (47두)에서 개선후 3% (12두) (73% 감소) 되었으며, 에너지 절감효과는 개선전 155만 원 (5,595 kw)에서 개선후 73만 원이었다. $\bigcirc$ 경제성을 분석한 결과 400두 돈사를 리모델링 할 경우 겨울철 4개월 (12월부터 3월까지) 사육할 경우 2,835,680원 이익을 얻을 수 있었다.