DOI QR코드

DOI QR Code

End-to-End Anastomosis of an Unanticipated Vertebral Artery Injury during C2 Pedicle Screwing

  • Nam, Kyung-Hun (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Sung, Joo-Kyung (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Park, Jae-Chan (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Cho, Dae-Chul (Department of Neurosurgery, Kyungpook National University Hospital)
  • 투고 : 2010.05.10
  • 심사 : 2010.09.27
  • 발행 : 2010.10.28

초록

Vertebral artery (VA) injury is a rare and serious complication of cervical spine surgery; this is due to difficulty in controlling hemorrhage, which can result in severe hypotension and cardiac arrest, and uncertain neurologic consequences. The authors report an extremely rare case of a 56-year-old woman who underwent direct surgical repair by end-to-end anatomosis of an unanticipated VA injury during C2 pedicle screwing. Postoperatively, the patient showed no neurological deterioration and computed tomography angiography of the VA demonstrated normal blood flow. Although direct occlusion of an injured VA by surgical ligation or endovascular embolization has been used for management of an unanticipated VA injury during surgery, these methods may be associated with significant morbidity and mortality. However, despite its technical demand, microvascular primary repair can restore normal blood flow and minimizes the risk of immediate or delayed ischemic complications. Here we report an iatrogenic VA injury during C2 pedicle screwing, which was successfully treated by end-to-end anastomosis.

키워드

참고문헌

  1. Cassinelli EH, Lee M, Skalak A, Ahn NU, Wright NM : Anatomic considerations fur the placement of C2 laminar screws. Spine (phila Pa 1976) 31: 2767-2771, 2006 https://doi.org/10.1097/01.brs.0000245869.85276.f4
  2. Chen JF, Wu CT, Lee SC, Lee ST : Posterior atlantoaxial transpedicular screw and plate fixation. Technical note. J Neurosurg Spine 2 : 386-392,2005 https://doi.org/10.3171/spi.2005.2.3.0386
  3. Coyne TJ, Fehlings MG, Wallace MC, Bernstein M, Tator CH: C1- C2 posterior cervical fusion : long-term evaluation of results and efficacy. Neurosurgery 37: 688-692; discussion 692-693, 1995 https://doi.org/10.1227/00006123-199510000-00012
  4. Ebraheim N, Rollins JR Jr, Xu R, Jackson WT : Anatomic consideration of C2 pedicle screw placoment. Spine (phila Pa 1976) 21 : 691-695, 1996 https://doi.org/10.1097/00007632-199603150-00005
  5. Epstein NE : From the neurointerventional lab...intraoperative cervical vertebral artery injury treated by tamponade and endovascular coiling. Spine J 3 : 404-405, 2003 https://doi.org/10.1016/S1529-9430(03)00079-2
  6. Goel A, Desai KI, Muzumdar DP : Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51 : 1351-1356; discussion 1356-1357, 2002 https://doi.org/10.1227/01.NEU.0000309110.78968.F5
  7. Golfinos JG, Dickman CA, Zabramski JM, Sonntag VK, Spetzler RF : Repair of vertebral artery injury during anterior cervical decompression. Spine (phila Pa 1976) 19 : 2552-2556, 1994 https://doi.org/10.1097/00007632-199411001-00010
  8. Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM : Constructs incorporating intralaminar C2 screws provide rigid stability fur atlantoaxial fixation. Spine (Phila Pa 1976) 30 : 1513-1518, 2005 https://doi.org/10.1097/01.brs.0000167827.84020.49
  9. Harms J, Melcher RP : Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26: 2467-2471, 2001 https://doi.org/10.1097/00007632-200111150-00014
  10. Heary RF, Albert TJ, Ludwig SC, Vaccaro AR, Wolansky LJ, Leddy TP, et al. : Surgical anatomy of the vertebral arteries. Spine (phila Pa 1976) 21 : 2074-2080, 1996 https://doi.org/10.1097/00007632-199609150-00004
  11. Inamasu J, Guiot BH : Iatrogenic vertebral artery injury. Acta Neurol Scand 112: 349-357, 2005 https://doi.org/10.1111/j.1600-0404.2005.00497.x
  12. MadawiAA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA: Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86: 961-968, 1997 https://doi.org/10.3171/jns.1997.86.6.0961
  13. Paramore CG, Dickman CA, Sonntag VK: The anatomical suita-bility of the C1-2 complex fur transarticular screw fixation. J Neurosurg 85 : 221-224,1996 https://doi.org/10.3171/jns.1996.85.2.0221
  14. Pfeifer BA, Freidberg SR, Jewell ER : Repair of injured vertebral artery in anterior cervical procedures. Spine (Phila Pa 1976) 19: 1471-1474, 1994 https://doi.org/10.1097/00007632-199407000-00009
  15. Prabhu VC, France JC, Voelker JL, Zoarski GH : Vertebral artery pseudoaneurysm complicating posterior Cl-2 transarticular screw fixation: case report. Surg Neurol 55 : 29-33; discussion 33-34, 2001 https://doi.org/10.1016/S0090-3019(00)00338-4
  16. Resnick DK, Lapsiwala S, Trost GR: Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine (Phila Pa 1976) 27 : 1494-1498, 2002 https://doi.org/10.1097/00007632-200207150-00003
  17. Shintani A, Zervas NT: Consequence of ligation of the vertebral artery. J Neurosurg 36: 447-450, 1972 https://doi.org/10.3171/jns.1972.36.4.0447
  18. Yoshida M, Neo M, Fujibayashi S, Nakamura T : Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31 : E513-E517, 2006 https://doi.org/10.1097/01.brs.0000224516.29747.52

피인용 문헌

  1. Delayed Vertebral Artery Dissection after Posterior Cervical Fusion with Traumatic Cervical Instability: A Case Report vol.12, pp.2, 2010, https://doi.org/10.14245/kjs.2015.12.2.79