Field study was conducted for 5 months to investigate the effect of leachate recirculation on aerobic landfill stabilization at active landfilling site. The area of field experiment was $24{\times}24m$ and 9 vertical air injection wells with screen ranging 3~9 m were installed. Aerobic landfill operation for 5 months increased average internal landfill temperature to $70^{\circ}C$ and 8 % of landfill height was settled down. $94m^3$ of leachate was recirculated for 1 month to increase moisture content of landfill to favor microbial degradation of organic matter, which resulted in temporary increase of groundwater level and anaerobic environment. But leachate recirculation triggered increase of internal landfill temperature of neighboring monitoring well. Because excessive leachate recirculation decreased internal landfill temperature by cooling effect, internal landfill temperature should be checked to avoid abrupt decrease of temperature during leachate recirculation. Also, to prevent anaerobic environment, intermittent leachate recirculation was recommended.
현재 매립 중인 폐기물 매립지 현장에서 공기주입을 5개월간 하였으며, 일정기간 침출수 주입을 병행하면서 이에 따른 매립지 조기안정화 효과를 관찰하였다. 실험부지 면적은 $24{\times}24m$ 규모이었으며, 부지 내에 3~9 m 깊이에 유공부를 설치한 9개의 공기주입용 수직정을 설치하였다. 매립지를 5개월 간 호기적으로 운전함에 따라 매립지 내부 평균 온도는 $70^{\circ}C$까지 상승하였으며, 매립고의 8 %에 해당하는 침하가 발생하였다. 미생물에 의한 유기물 분해촉진을 위하여 1개월간 $94m^3$의 침출수를 실험부지의 일부 구역에 재순환시킨 결과 일시적으로 매립지 내 지하수위가 상승하였고, 혐기성 환경이 조성되었다. 하지만, 침출수 재순환은 침출수 주입정 주변의 매립지 내부 온도를 급속히 상승시키는 효과를 가져왔다. 그러나 과도한 침출수 주입은 매립지 내부를 냉각시켜 온도 상승을 저하시키는 효과를 나타내므로, 매립지 내부온도 변화를 관찰하면서 침출수 주입량을 조절할 필요가 있으며, 침출수 주입은 간헐적으로 하는 것이 바람직하다.