Development of a Wireless Vibration Monitoring System for Structural Health Evaluation

구조안전성 평가를 위한 무선 진동 모니터링 시스템 개발

  • 심보군 (삼성엔지니어링 기술연구소) ;
  • 이시복 (부산대학교 기계공학부, RIMT) ;
  • 채민성 (삼성엔지니어링 기술연구소)
  • Published : 2010.02.20

Abstract

Wired monitoring systems have been used for damage detection and dynamic analysis of large structures(bridges, dams, plants, etc.). However, the real-world applications still remain limited, mainly due to time and cost issues inherent to wired systems. In recent years, an increasing number of researchers have adopted WSN(wireless sensor network) technologies to the field of SHM(structural health monitoring). Accurate time synchronization is most critical for the wireless approach to be feasible for SHM purpose, along with sufficient wireless bandwidth and highly precise measuring resolution. To satisfy technical criteria stated above, a wireless vibration monitoring system that uses high-precision MEMS(micro-electro-mechanical system) sensors and A/D convertor is discussed in detail. It was found experimentally that the level of time synchronization fell within $200\;{\mu}sec$.

Keywords

References

  1. Kim, S. K., 2006, "Signal Analysis from a Long-term Bridge Monitoring System in Yong jong Bridge," Journal of Earthquake Engineering Society of Korea, Vol. 10, No. 6, pp. 9-18. https://doi.org/10.5000/EESK.2006.10.6.009
  2. Straser, E. G. and Kiremidjian, A. S., 1998, "A Modular Wireless Damage Monitoring System for Structures," Report No. 128, John A. Blume Earthquake Engineering Center, Department of Civil and Environmental Engineering, Stanford University, Stanford, CA.
  3. Hwang, J. H. and Park, J. H., 2003, "A Conceptual Design for the Development of a Remote Structural Monitoring System," Journal of the Institute of Construction Technology, Vol. 22, No. 2, pp. 260-269.
  4. Son, J. D., 2008, "Development of MEMS Accelerometer-based Smart Sensor for Machine Condition Monitoring," Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 18, No. 8, pp. 872-878. https://doi.org/10.5050/KSNVN.2008.18.8.872
  5. Lee, J. S., 2007, "A Comparative Study of Wireless Protocols: Bluetooth, UWB, ZigBee and Wi-Fi," The 33rd Annual Conference of the IEEE Industrial Electronics Society(IECON), Taiwan.
  6. Bin, B. U and Lee, J. H, 2007, "A Scheme to Reduce the Transmission Delay for Real-time Applications in Sensor Networks," The Journal of the Korean Institute of Maritime & Communication Sciences, Vol. 11, No. 8, pp. 1493-1499.
  7. http://www.strixsystems.com
  8. Colin G. Gordon., 1999, "Generic Vibration Criteria for Vibration Sensitive Equipment," Proceedings of International Society for Optical Engineering(SPIE) Conference on Current Developments in Vibration Control for Optome- chanical System, Denver, CO.

Cited by

  1. Band-pass Filter based Artificial Filter Bank for Structural Health Monitoring vol.25, pp.12, 2015, https://doi.org/10.5050/KSNVE.2015.25.12.843
  2. Development of Real Time Smart Structure Monitoring System for Bridge Safety Maintenance using Sensor Network vol.16, pp.2, 2016, https://doi.org/10.5392/JKCA.2016.16.02.221