PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun (Department of Nuclear Engineering, Hanyang University) ;
  • Han, Young-Yih (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kum, O-Yeon (School of Electronics Engineering, Kyungbook National University) ;
  • Kim, Chan-Hyeong (Department of Nuclear Engineering, Hanyang University) ;
  • Ju, Sang-Gyu (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Shin, Jung-Suk (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Jin-Sung (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Joo-Hwan (Korea Atomic Energy Research Institute)
  • 투고 : 2010.04.28
  • 심사 : 2010.10.14
  • 발행 : 2010.12.31

초록

In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.

키워드

참고문헌

  1. A. Sankar, et al., “Comparison of Kodak EDR2 and Gafchromic EBT Film for Intensity-modulated Radiation Therapy Dose Distribution Verification,” Med Dosim., 31, 273 (2006). https://doi.org/10.1016/j.meddos.2006.06.001
  2. M. Fuss, E. Sturtewagen, C. D. Wagter, and D. Georg, “Dosimetric Characterization of GafChromic EBT Film and Its Implication on Film Dosimetry Quality Assurance,” Phys. Med. Biol., 52, 4211 (2007). https://doi.org/10.1088/0031-9155/52/14/013
  3. S. Devic, et al., “Precise Radiochromic Film Dosimetry using a Flat-bed Document Scanner,” Med. Phys., 32, 2245 (2005). https://doi.org/10.1118/1.1929253
  4. C. Fiandra, et al., “Clinical Use of EBT Model $Gafchromic^{TM}$ Film in Radiotherapy,” Med. Phys., 33, 4314 (2006). https://doi.org/10.1118/1.2362876
  5. L. Menegotti and A. Delana, “Radiochromic Film Dosimetry with Flatbed Scanners: A Fast and Accurate Method for Dose Calibration and Uniformity Correction with Single Film Exposure,” Med. Phys., 35, 3078 (2008). https://doi.org/10.1118/1.2936334
  6. E. E. Wilcox and G. Daskalov, “Evaluation of $GAFCHROMIC^{\circledR}$ EBT Film for $CyberKnife^{\circledR}$ Dosimetry,” Med. Phys., 34, 1967 (2007). https://doi.org/10.1118/1.2734384
  7. ISP Paper: http://www.ispcorp.com/products/dosimetry/content/gafchromic/content/products/ebt/pdfs/EffectLight.pdf.
  8. Product manual: http://online1.ispcorp.com/_layouts/Gafchromic/content/products/ebt/pdfs/EBTwhitepaper.pdf.
  9. L. J. Van Battum, D. Hoffmans, H. Piersma, and S. Heukelom, “Accurrate Dosimetry with GafchromicTMEBT Film of a 6 MV Photon Beam in Water: What Level is Achievable?,” Med. Phys., 35, 704 (2008). https://doi.org/10.1118/1.2828196
  10. T. Depuydt, A. Van Esch, and D. P. Huyskens, “A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation,” Radiother. Oncol., 62, 309 (2002). https://doi.org/10.1016/S0167-8140(01)00497-2
  11. S. Both et al., “A study to establish reasonable action limits for patient-specific quality assurance in intensitymodulated radiation therapy,” J. Appl. Clin. Med. Phys., 8, 1 (2007)
  12. B. E. Nelms and J. A. Simon, “A survey on planar IMRT QA analysis,” J. Appl. Clin. Med. Phys., 8, 76 (2007).
  13. Y. S. Yoo, and S. G. Ro, “Gamma-ray Dosimetry with Thin Plastic Film,” Nucl. Eng. & Tech., 5, 223 (1973).
  14. Y. S. Yoo, “Electron Dose Measurement with Polycarbonate Film Dosimeter,” Nucl. Eng. & Tech., 8, 9 (1976).
  15. O. A. Zeidan, et al., “Characterization and Use of EBT Radiochromic Film for IMRT Dose Verification,” Med. Phys., 33, 4064 (2006). https://doi.org/10.1118/1.2360012
  16. M. Todorovic, M. Fischer, F. Cremers, E. Thom, and R. Schmidt, “Evaluation of GafChromic EBT Prototype B for External Beam Dose Verification,” Med. Phys., 33, 1321 (2006). https://doi.org/10.1118/1.2188077
  17. E. E. Wilcox, G. Daskalov, and L. Nedialkova, “Comparison of the Epson Expression 1680 Flatbed and the Vidar VXR-16 Dosimetry PROTM Film Scanners for Use in IMRT Dosimetry Using Gafchromic and Radiographic Film,” Med. Phys., 34, 41 (2006).
  18. L. Paelinck, W. D. Neve, and C. D. Wagter, “Precautions and Strategies in Using a Commercial Flatbed Scanner for Radiochromic Film Dosimetry,” Phys. Med. Biol., 52, 231 (2007). https://doi.org/10.1088/0031-9155/52/1/015
  19. M. Martisíkova, B. Ackermann, and O. JAkel, “Analysis of Uncertainties in $Gafchromic{\circledR}$ EBT Film Dosimetry of Photon Beams,” Phys. Med. Biol., 53, 7013 (2008). https://doi.org/10.1088/0031-9155/53/24/001

피인용 문헌

  1. Quantitative analysis of dose distribution to determine optimal width of respiratory gating window using Gafchromic EBT2 film vol.62, pp.4, 2013, https://doi.org/10.3938/jkps.62.657