DOI QR코드

DOI QR Code

Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area

안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사

  • Heo, Jong-Won (Gyeonggi-do Institute of Health and Environment) ;
  • Kim, Dong-Gi (Gyeonggi-do Institute of Health and Environment) ;
  • Song, Il-Seok (Gyeonggi-do Institute of Health and Environment) ;
  • Lee, Gang-Woong (Department of Environmental Science, Hankuk University of Foreign Studies)
  • 허종원 (경기도보건환경연구원) ;
  • 김동기 (경기도보건환경연구원) ;
  • 송일석 (경기도보건환경연구원) ;
  • 이강웅 (한국외국어대학교 환경학과)
  • Received : 2010.04.16
  • Accepted : 2010.08.30
  • Published : 2010.10.31

Abstract

After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.

Keywords

References

  1. Abad, E., K. Marínez, L. Gustems, R. Gomez, X. Guinart, I. Herna´ndez, and J. Rivera (2007) Ten years measuring PCDDs/PCDFs in ambient air in Catalonia (Spain), Chemosphere, 67, 1709-1714. https://doi.org/10.1016/j.chemosphere.2006.05.083
  2. Alcock, R.E. and K.C. Jones (1996) Dioxins in the environment: A review of trend data, Environ. Sci. Technol., 30, 3133-3143. https://doi.org/10.1021/es960306z
  3. Ansan City (2006) White Paper of Environment 2006.
  4. Assuncao, J.V. de., C.R. Pesquero, R.E. Bruns, and L.R.F. Carvalho (2005) Dioxins and furans in the atmosphere of Sao Paulo City, Brazil, Chemosphere, 58, 1391-1398. https://doi.org/10.1016/j.chemosphere.2004.10.003
  5. Bidleman, T.F. (1988) Atmospheric processes: wet and dry deposition of organic compounds controlled by their vapor particle partitioning, Environ. Sci. Technol., 22, 361-367. https://doi.org/10.1021/es00169a002
  6. Carlson, D.L. and R.A. Hites (2005) Temperature dependence of atmospheric PCB concentrations, Environ. Sci. Technol., 39, 740-747. https://doi.org/10.1021/es049081f
  7. Caserini, S., S. Cernuschi, M. Giugliano, M. Grosso, G. Lonati, and P. Mattaini (2004) Air and soil dioxin levels at three sites in Italy in proximity to MSW incineration plants, Chemosphere, 54, 1279-1287. https://doi.org/10.1016/S0045-6535(03)00250-9
  8. Chao, M.R., C.W. Hu, Y.L. Chen, G.P. Chang-Chien, W.J. Lee, L.W. Chang, W.S. Lee, and K.Y. Wu (2004) Approaching gas particle partitioning equilibrium of atmospheric PCDD/Fs with increasing distance from an incinerator: measurements and observations on modeling, Atmos. Environ., 38, 1501-1510. https://doi.org/10.1016/j.atmosenv.2003.11.034
  9. Cheng, P.S., M.S. Hsu, E. Ma, U. Chou, and Y.C. Ling (2003) Levels of PCDD/Fs in ambient air and soil in the vicinity of a municipal solid waste incinerator, in Hsinchu, Chemosphere, 52, 1389-1396. https://doi.org/10.1016/S0045-6535(03)00474-0
  10. Cindoruk, S.S. and Y. Tasdemir (2007) Characterization of gas/particle concentrations and partitioning of polychlorinated biphenyls (PCBs) measured in an urban site of Turkey, Environmental Pollution, 148, 325-333. https://doi.org/10.1016/j.envpol.2006.10.018
  11. Coutinho, M., M. Pereira, and C. Borrego (2007) Monitoring of ambient air PCDD/F levels in Portugal, Chemosphere, 67, 1715-1721. https://doi.org/10.1016/j.chemosphere.2006.05.084
  12. Eitzer, B.D. and R.A. Hites (1988) Vapor pressures of chlorinated dioxins and dibenzofurans, Environ. Sci. Technol., 22, 1362-1364. https://doi.org/10.1021/es00176a018
  13. Falconer, R.L. and T.F. Bidleman (1994) Vapor pressures and predicted particle/gas distributions of PCB congeners as functions of temperature and ortho-chlorine substitution, Atmos. Environ., 28, 547-554. https://doi.org/10.1016/1352-2310(94)90130-9
  14. Finzio, A., D. Mackay, and T.F. Bidleman (1997) Octanol-air partition coefficient as a predictor of partitioning of semi-volatile organic chemicals to aerosols, Atmos. Environ., 15, 2289-2296. https://doi.org/10.1016/S1352-2310(97)00013-7
  15. GIHE (Gyeonggi-do Institute of Health & Environment) (2008) Monitoring of dioxin in the air/soil and human risk assessment for inhalation of the air/soil.
  16. Goss, K.U. and R.P. Schwarzenbach (1998) Gas/solid and gas/liquid partitioning of organic compounds: critical evalutation of the interpretation of equilibrium constants, Environ. Sci. Technol., 32, 2025-2032. https://doi.org/10.1021/es9710518
  17. Harner, T. and T.F. Bidleman (1996) Measurements of octanolair partitioning coefficients for polychlorinated biphenyls, Journal of Chemical and Engineering Data, 41, 895-899. https://doi.org/10.1021/je960097y
  18. Harner, T. and T.F. Bidleman (1998) Octanol-air partitioning coefficients for describing particle/gas partitioning of aromatic compounds in urban air, Environ. Sci. Technol., 32, 1494-1502. https://doi.org/10.1021/es970890r
  19. Harner, T., N.J.L. Green, and K.C. Jones (2000) Measurements of octanol-air partition coefficients for PCDD/Fs: a tool in assessing air-soil equilibrium status, Environ. Sci. Technol., 34, 3109-3114. https://doi.org/10.1021/es000970m
  20. Hippelein, M., H. Kaupp, G. Dorr, M.S. McLachlan, and O. Hutzinger (1996) Baseline contamination assessment for a new resource recovery facility in Germany Part II: Atmospheric concentrations of PCDD/F, Chemosphere, 32, 1605-1616. https://doi.org/10.1016/0045-6535(96)00070-7
  21. Jones, K.C. and R. Duarte-Davidson (1997) Transfer of airborne PCDD/Fs to bulk deposition collectors and herbage, Environ. Sci. Technol., 31, 2937-2943. https://doi.org/10.1021/es970133t
  22. Junge, C.E. (1977) Fate of pollutants in the air and water environment, Part 1, Vol.8, Wiley Interscience, New York, pp. 7-25.
  23. Kim, K.-S. (2009) Characteristics of contamination and fate for PCDD/Fs in ambient air, Cheongju, Korean Society of Environmental Engineers, 31, 294-299. (in Korean with English abstract)
  24. Lee, C.L., H.L. Chen, H.J. Su, Y.L. Guo, and P.C. Liao (2005) Evaluation of PCDD/Fs patterns emitted from incinerator via direct ambient sampling and indirect serum levels assessment of Taiwanese, Chemosphere, 59, 1465-1474. https://doi.org/10.1016/j.chemosphere.2004.12.075
  25. Lee, S.J., S.D. Choi, G.Z. Jin, J.E. Oh, Y.S. Chang, and S.K. Shin (2007) Assessment of PCDD/F risk after implementation of emission reduction at a MSWI, Chemosphere, 68, 856-863. https://doi.org/10.1016/j.chemosphere.2007.02.036
  26. Li, H., J. Feng, J. Sheng, S. Lü, J. Fu, P. Peng, and R. Man (2008) The PCDD/F and PBDD/F pollution in the ambient atmosphere of Shanghai, China, Chemosphere, 70, 576-583. https://doi.org/10.1016/j.chemosphere.2007.07.001
  27. Lia, Y., G. Jianga, Y. Wanga, Z. Caib, and Q. Zhanga (2008) Concentrations, profiles and gas-article partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Beijing, China, Atmos. Environ., 42, 2037-2047. https://doi.org/10.1016/j.atmosenv.2007.12.005
  28. Lohmann, R. and K.C. Jones (1998) Dioxins and furans in air and deposition: A review of levels, behaviour and processes, The Science of the Total Environment, 219, 53-81. https://doi.org/10.1016/S0048-9697(98)00237-X
  29. Lohmann, R., R.G.M. Lee, N.J.L. Green, and K.C. Jones (2000a) Gas-particle partitioning of PCDD/Fs in daily air samples, Atmos. Environ., 34, 2529-2537. https://doi.org/10.1016/S1352-2310(99)00515-4
  30. Lohmann, R., T. Harner, G.O. Thomas, and K.C. Jones (2000) A comparative study of the gas-particle partitioning of PCDD/Fs, PCBs, and PAHs, Environ. Sci. Technol., 34, 4943-4951. https://doi.org/10.1021/es9913232
  31. Mandalakis, M., M. Tsapakis, A. Tsoga, and E.G. Stephanou (2002) Gas-particle concentrations and distribution of aliphatic hydrocarbons, PAHs, PCBs and PCDD/Fs in the atmosphere of Athens (Greece), Atmos. Environ., 36, 4023-4035. https://doi.org/10.1016/S1352-2310(02)00362-X
  32. Mari, M., M. Schuhmacher, J. Feliubadalo, and J.L. Domingo (2008) Air concentrations of PCDD/Fs, PCBs and PCNs using active and passive air samplers, Chemosphere, 70, 1637-1643. https://doi.org/10.1016/j.chemosphere.2007.07.076
  33. Ministry of Environment, Japan (2009) Information Brochure Dioxins 2009 (http://www.env.go.jp/en/chemi/pops/).
  34. NIER (National Institute for Environmental Research) (2009) Survey for endocrine disruptors in environmental media.
  35. Oh, J.E., S.D. Choi, S.J. Lee, and Y.S. Chang (2006) Influence of a municipal solid waste incinerator on ambient air and soil PCDD/Fs levels, Chemosphere, 64, 579-587. https://doi.org/10.1016/j.chemosphere.2005.11.012
  36. Ok, G., S.H. Lee, I.J. Hwang, and S.M. Hwang (2009) EvalEvaluation of UPOPs (PCDD/DFs, Dioxinlike PCBs and Hexachlorobenzene; HxCB) in ambient air, air deposition and soil of Ulsan, Korea, J. of the Korean Society for Environmental Analysis, 12, 233-246. (in Korean with English abstract)
  37. Pankow, J.F. (1987) Review and comparative analysis of the theories on partitioning between the gas and aeerosol particulate phases in the atmosphere, Atmos. Environ., 22, 2275-2283.
  38. Pankow, J.F. (1994) An absorption model of gas/particle partitioning of organic compounds in the atmosphere, Atmos. Environ., 28, 185-188. https://doi.org/10.1016/1352-2310(94)90093-0
  39. Pankow, J.F. and T.F. Bidleman (1992) Interdependence of the slopes and intercepts from log-log correlations of measured gas-particle partitioning and vapor pressure-1. Theory and analysis of available data, Atmos. Environ., 26A, 1071-1080. https://doi.org/10.1016/0960-1686(92)90039-N
  40. Raun, L.H., O. Correa, H. Rifai, M. Suarez, and L. Koenig (2005) Statistical investigation of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Houston, Texas, Chemosphere, 60, 973-989. https://doi.org/10.1016/j.chemosphere.2004.12.057
  41. Robinson, N. (1996) Solar Radiation, Amsterdam, Elsevier, 347pp.
  42. Shih, S.I., Y.F. Wang, J.E. Chang, J.S. Jang, F.L. Kuo, L.C. Wang, and G.P. Chang-Chien (2006) Comparisons of levels of polychlorinated dibenzo-p-dioxins/dibenzofurans in the surrounding environment and workplace of two municipal solid waste incinerators, J. Hazard. Mater., B137, 1817-1830. https://doi.org/10.1016/j.jhazmat.2006.05.022
  43. Simcik, M.F., T.P. Franz, H. Zhang, and S.J. Eisenreich (1998) Gas/particle partitioning of PCBs and PAHs in the Chicago urban and adjacent coastal atmosphere: states of equilibrium, Environ. Sci. Technol., 32, 251-257. https://doi.org/10.1021/es970557n
  44. U.S. EPA (2006) An Inventory of Sources and Environmental Releases of Dioxin-Like Compounds in the U.S. for the Years 1987, 1995, and 2000, EPA/600/P-03/002f, Final Report.
  45. Venier, M., J. Ferrario, and R.A. Hites (2009) Polychlorinated Dibenzo-p-dioxins and dibenzofurans in the atmosphere around the great lakes, Environ. Sci. Technol., 43, 1036-1041. https://doi.org/10.1021/es802644w
  46. Wang, J.B., G.P. Chang-Chienb, W.Y. Linc, J.H. Yehd, and C.H. Hungb (2009) A seasonality study of polychlorinated dibenzo-p-dioxins and dibenzofurans in ambient air in Kaohsiung (Taiwan) clustered with metallurgical industries, J. Hazard. Mater., 162, 103-110. https://doi.org/10.1016/j.jhazmat.2008.05.014
  47. Wu, Y.L., L.F. Lin, L.T. Hsieh, L.C. Wang, and G.P. Chang-Chien (2009) Atmospheric dry deposition of polychlorinated dibenzo-pdioxins and dibenzofurans in the vicinity of municipal solid waste incinerators, J. Hazard. Mater., 162, 521-529. https://doi.org/10.1016/j.jhazmat.2008.05.075
  48. Xu, M.X., J. Huayan, S.Y. Lu, X.D. Li, T. Chen, M.J. Ni, H.F. Dai, F. Wang, and K.F. Cen (2009) Concentrations, profiles, and sources of atmospheric PCDD/Fs near a municipal solid waste incinerator in eastern China, Environ. Sci. Technol., 43, 1023-1029. https://doi.org/10.1021/es802183b
  49. Yamasaki, H., K. Kuwata, and H. Mlyamoto (1982) Effects of ambient temperature on aspects of airborne polycyclic aromatic hydrocarbons, Environ. Sci. Technol., 16, 189-194. https://doi.org/10.1021/es00098a003

Cited by

  1. Depositional Characteristics of Atmospheric PBDEs on Pine Needles, Bark and Soil vol.40, pp.3, 2014, https://doi.org/10.5668/JEHS.2014.40.3.215
  2. Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea vol.31, pp.6, 2015, https://doi.org/10.5572/KOSAE.2015.31.6.548