DOI QR코드

DOI QR Code

Comparison and Analysis about CCT of LED Luminaire According to Light Sources and Compounded CCT

광원과 CCT 조합에 따른 LED 조명기구의 CCT 비교 분석

  • 김인태 (세종대학교 건축공학과) ;
  • 김유신 (세종대학교 건축공학과) ;
  • 최안섭 (세종대학교 건축공학과)
  • Received : 2010.06.17
  • Accepted : 2010.09.06
  • Published : 2010.12.31

Abstract

Recently, adjustable CCT(Correlated Color Temperature) luminaire for the human circadian rhythm and room atmosphere has been developed. Accurate CCT control is needed in the luminaire for the human circadian rhythm. Therefore, appropriate CCT calculation method for each of fluorescent lamps and white LEDs was examined using three CCT calculation methods in this study. To make accurate CCT combination, CCT for two different CCT lamps was separately measured. And this study compared and analyzed proportionally calculated CCT value with measured value from the compounded luminaire with the two lamps.

Keywords

References

  1. 장준호, 주관평가를 통한 공간별 적합 색온도에 관한 연구, 대한건축학회 학술발표대회 논문집, 제27권 제1호, p985-988, 2007.
  2. 황명근, 조명공학개론, 성우, 2003.
  3. R.H.Simons 외 1, Lighting Engineering Applied calculations, Butterworth-Heinemann, 2001.
  4. 오오타 노보루, 색채공학, 국제, 2003.
  5. 김훈 외 1, 광원의 색온도 및 연색성 변화에 관한 연구, 한국조명. 전기설비학회지, 제5권 제2호, p49-57, 1991.
  6. Javier Hernandez-Andres 외 2, Calculating correlated color temperatures across the entire gamut of daylight and skylight chromaticities, APPLIED OPTICS, Vol. 38, No.27, p5703-5709, 1999. https://doi.org/10.1364/AO.38.005703

Cited by

  1. Analysis on the Measured Electric Power Consumption of Dimmable LED Lamps for a Specific Illuminance and Color Temperature vol.25, pp.2, 2011, https://doi.org/10.5207/JIEIE.2011.25.2.024