This study proposes the optimal ratio of vertical load-carrying capacity (${\beta}$) by investigating structural performances and economic efficiency in the extradosed bridges. Without design standards for the extradosed bridge, Japanese design standards have been used domestically. For the design live load, DL24 is found to be more adequate than DB24. Using the DL24 load, parameter studies are carried out. The parameters are 'main tower height', 'main girder stiffness', and 'cable arrangement'. As a result, it is found that one side cable-stayed extradosed bridges are more economical than double side cable-stayed extradosed bridges. This study also shows that when the ratio of vertical load-carrying capacity(${\beta}$) is 30~50% in the extradosed bridge with the ratio of tower height to main span length 1/6, the extradosed bridge is most economical because of the cable stress less than the allowable stress.
본 연구에서는 기존 엑스트라도즈드교와 PSC 사장교 사이의 영역인 주탑고비 1/6~1/7의 고주탑을 적용하여 엑스트라도즈드교의 구조적, 경제적 특성을 평가하였다. 주탑고가 증가함에 따라 사재의 연직하중 분담율의 증가와 함께 변동응력도 증가하여 사재의 피로안정성이 주요 설계변수임을 알 수 있었다. 국내에서는 엑스트라도즈드교의 설계기준 부재로 인하여 일본 설계기준을 준용하고 있다. 또한, 피로 검토하중도 정립되지 않고 있어 본 연구에서는 일본 피로 검토하중에 대응하는 국내 활하중을 적용 검토하여 DL24 하중이 피로 검토하중으로 적정함을 알 수 있었다. 제시된 피로 검토하중을 적용하여 주탑고, 주거더의 강성, 케이블 면수 등을 매개변수로 엑스트라도즈드교의 구조적, 경제적 특성을 검토하였다. 본 연구의 결과로써 일면 케이블 배치가 이면 케이블 배치보다 경제적임을 알 수 있었다. 또한, 주탑고비가 1/6의 변단면 고주탑 엑스트라도즈교에서 연직 하중분담율이 30~50% 이내로 모든 사재가 허용변동응력 이내로 들어와 사재를 효율적으로 사용할 수 있어 가장 경제적임을 알 수 있었다. 본 연구를 통해 기존의 엑스트라도즈드교보다 높은 주탑고를 적용함에 따라 구조적, 경제적으로 효율성을 높일 수 있음을 확인하였다.