소부대 전투시설 방호두께 기준의 타당성 검토에 대한 기초 연구

A Feasibility Study Evaluating Standards for Covered-Positions Built with Concrete Materials

  • 발행 : 2009.10.05

초록

In terms of protective engineering, there are no noticeable researches regarding covered-positions for smaller units in South Korea. So, standards to maintain and build protective facilities for larger units have been applied in ones for smaller units without any adjustment. The previous study was to calculate penetration depth of the concrete walls because the experiment performed indoor. In this outdoor experiment, velocity of projectile impact as one of the other important factors was considered to prove the validity of 30cm concrete wall thickness as effective protective level of the covered-position. Random effects and extraneous variables which could be occurred in outdoors experiment were controlled with statistical techniques. As a result, velocity of projectile impact was significant variable and the given standard, 30cm thickness of concrete walls was as valid as ever.

키워드

참고문헌

  1. 김석봉 외, '소구경 탄자에 대한 철근콘크리트 슬래브의 관입저항력 평가', 한국군사과학기술학회지 제10권 제2호, pp. 69-75, 2007
  2. 김석봉 외, '신소재를 이용한 전투시설 구축방안에 관한 연구', 화랑대연구소, 2003
  3. 김제영 외, '확률 및 통계', 청문각, 1997
  4. 박성현, '회귀분석', 대영사, 2004
  5. 서관세 외, '군 방호 구조물 최적설계에 관한 기초연구', 화랑대연구소, 1993
  6. 서관세 외, '비핵탄용 다층복합 군방호 구조물 연구', 화랑대연구소, 1995
  7. 전병호 외, '방호공학', 청문각, 2006
  8. '진지 및 방호시설', 육군본부, 1998
  9. 'M60 기관총', 육군본부, 1998