The Preparation of Polyacrylonitrile Diagnostic Membranes for Blood Glucose Measurements (3) : Effects of Storage Environments on the Measurements of Glucose Concentration

혈당측정을 위한 폴리아크릴로니트릴 진단막의 제조(3) : 보관 환경이 글루코우즈의 농도 측정에 미치는 영향

  • Kwon, Suk-Ky (Department of Chemical System Engineering, Hongik University) ;
  • Yu, Jae-Woo (Department of Chemical System Engineering, Hongik University)
  • 권석기 (홍익대학교 과학기술대학 화학시스템공학과) ;
  • 유재우 (홍익대학교 과학기술대학 화학시스템공학과)
  • Published : 2009.09.30

Abstract

Polyacrylonitrile diagnostic membranes were prepared to make blood-glucose self-checking system for diabetics. After the prepared polyacrylonitrile membranes were stored at sereval different environments, final absorbances at 680 nm were measured at various concentration in blood. The mesured blood-glucose level did not show the big differences at the various storage temperatures. It was found that the blood-glucose level decreased a little bit compared to the standard value after $10{\sim}30$ hours at high humidities.

당뇨병 환자의 자가 혈당 측정 장치에 사용할 수 있는 폴리아크릴로니트릴 진단막을 제조하였다. 제조된 폴리아크릴로니트릴 진단막을 여러 가지 환경에서 보관한 후 혈액 속의 글루코우즈의 농도를 변화시켜가며 680 nm에서의 최종 흡광도를 측정하였다. 측정된 혈당치가 보관 온도의 변화에 따라서는 크게 차이를 보이지 않았다. 다만 여러 가지 습도에서 보관한 후 측정한 결과 높은 습도에서 장기간 보관한 후의 혈당치가 기준 값보다 다소 감소하는 것을 알 수 있었다.

Keywords

References

  1. S. Kwon and M. Choi, 'The Preparation of Polyacrylonitrile Diagnostic Membranes for Blood Glucose Measurements (2) : Effects of Blood con-stituens on the Measurements of Glucose Concentration', Membrane Journal, 18, 4 (2008)
  2. T. Asano and T. Norioka, 'Diabetes', Nihon Bungeisha, Tokyo (2000)
  3. T. Asano, 'Diabetic Food and Life style', ShufuTo-Seikatsusha Co., Tokyo (2005)
  4. K. Huh, 'Diabetic Health', D&C, Seoul (2006)
  5. S. Kim, 'Life Guide for Diabetes Control', Hyoseong, Seoul (1993)
  6. J. Kim, 'Dabetes : Diagnostics and Control', Ohsung, Seoul (1997)
  7. K. Lee, 'Modem Disease Digest', Kuckminilbosa, Seoul (1992)
  8. Home Health Management Research Institute, 'Diabetes', Kumyoung, Seoul (1992)
  9. S. Kwon, 'Studies on the preparation of Diagnostic Membranes for Blood Glucose Measurements (3) Effects of Hematocrit on the Measurements of Glucose Concentration', Hongik Industrial Technology, 14 (2004)
  10. S. Kwon, 'Studies on the Polyurethane Diagnostic Membrane for Diabetes (2) Effects of Additives in Membrane Formulations for the Measurement of Urine Glucose', Polymer (Korea), 18, 6 (1994)
  11. S. Kwon, 'Studies on the Preparation of Diagnostic Membranes for Blood Glucose Measurements (2) : Effects of Temperature on the Measurements of Glucose Concentration', Hongik lndlatrial Technology, 13 (2003)
  12. S. Kwon, 'Basic Studies on the Preparation of Diagnostic Membranes by Using Multi-Layered Gelatin Films to Measure Blood Glucose Level of Diabetics', Membrane Journal, 8, 1 (1998)
  13. S. Kwon and B. Lee, 'Studies on the Multi-Layered Gelatin Diagnostic Membranes for Diabetes (1) : Effects of Temperature and Hurnidity on the Diffusion-Controlled Rates of Glucose', Membrane Journal, 9, 2 (1992)
  14. S. Kwon, 'Studies on the Muti-Layered Gelatin Diagnostic Membranes for Diabetes (2) : Effects of Interferents in Blood on the Diffusion-Controlled Rates of Glucose', Membrane Journal, 9, 4 (1999)
  15. S. Kwon, 'Studies on the Muti-Layered Gelatin Diagnostic Membranes for Diabetes (2) : Effects of Interferents in Blood on the Diffusion-Controlled Rates of Glucose', Membrane Joumal, 9, 4 (1999)
  16. R. E. Kesting, 'Synthetic Po1ymeric Membranes', Wiley. Interscience, New York (1985)
  17. S. Kwon, 'Studies on the preparation of Diagnostic Membranes fir Blood Glucose Measurements (1) : Model Experiments by Using Microporous Polyurethane Membrane', Hongik lnsustrial Technology, 12 (2002)
  18. S. Kwon, 'Studies on the Preparation of Diagnostic Mεmbranes for Blood Glucose Measurements (4) : Effects of Additives in Blood on the Measurements of Glucose Concentration', Hongik lndustrial Technology, 15 (2005)
  19. S. Kwon, 'A Study on the Preparation of Polyurethane Diagnostic Membrane for Urine Glucose Test', J. Kor. lnd. & Eng. Chem., 5, 6 (1994)
  20. S. Kwon, 'A Study on the Preparation of Polyurethane Diagnostic Membrane for Urine Glucose Test', J. Kor. lnd. & Eng. Chem., 5, 6 (1994)
  21. S. Kwon, I. Park, and D. Yoon, 'The Preparation of Polyacrylonitrile Diagonostic Membranes for Blood Glucose Measurements (1): Effects of Temperature and Hurnidity on the Measurements of Glucose Concentration', Membrane Jounal, 17, 4 (2007)