Determining the Proper Capacity of Electric Vehicle Charging Station

전기자동차 충전소의 적정 용량 결정

  • Published : 2009.10.01

Abstract

The problem of determining the proper capacity of electric vehicle charging station is studied in the presented paper. Based on the expected arrival rate and the expected charging time, we calculate the proper capacity that guarantees electric vehicles get service better than a given lower bound which is termed the loss of charging probability. The problem is studied by using certain queueing models. We first formulate the problem as a queueless model of type M/M/n/n, known as the Erlang loss system. And then the M/M/n/K type queueing model is formulated to consider the parking space constraint. Results of the study may be used for designing the electric vehicle charging station.

Keywords

References

  1. Public law 109-58-AUG. 8, 2005, 'Energy Policy Act of 2005'
  2. Jim W. Roberts, 'Traffic Theory and the Internet', IEEE Communications Magazine, Jan. 2001 https://doi.org/10.1364/OPEX.13.009702
  3. G. Koole and A. Mandelbaum, 'Queueing Models of Call Centers: An Introduction,' Technical Report 2001-7, Dept. of Stochastics, Vrije Universiteit Amsterdam, 2001
  4. Moshe Zukerman, 'Introduction to Queueing Theory and Stochastic Teletraffic Models,' available online: http://www.ee.unimelb.edu.au/staff/mzu/classnotes.pdf
  5. R.B. Cooper, Introduction to Queueing Theory, second ed. North-Holland, 1981
  6. 'Installation guide for Electric Vehicle Charging Equipment', Massachusetts Division of Energy Resources, Sep. 2000
  7. http://en.wikipedia.org/wiki/Chevrolet_Volt