DESIGN AND CONSTRUCTION OF AN ADVANCED SPENT FUEL CONDITIONING PROCESS FACILITY (ACPF)

  • Published : 2009.08.31

Abstract

KAERI has worked on the development of an advanced spent fuel conditioning process (ACP) since 1997. A hot cell facility, termed the ACPF, has also been developed. The ACPF consists of two air-sealed hot cells. The results of a safety analysis as part of the license procurement process stipulated by the Korean Government showed that the facility was designed safely. After its construction, an integrated performance test was performed. The results of this test confirmed that the facility satisfies the design requirements.

Keywords

References

  1. S. W. Park et al., “Development of Advanced Spent Fuel Management Process,” KAERI/RR-2427/2003 (2004)
  2. G. S. You et al., “Development of Experimental Facilities for Advanced Spent Fuel Management Technology,” KAERI/RR-2431/2003 (2004)
  3. J. S. Yoon et al., “Spent Fuel Remote Technology Development,” KAERI/RR-2425/2003 (2004)
  4. H. D. Kim et al, “Development of Spent Fuel Examination Technology,” KAERI/RR-2432/2003 (2004)
  5. G. S. You et al., “Safety Evaluation Report of Hot Cell Facilities for Demonstration of Advanced Spent Fuel Conditioning Process,” KAERI/TR-2832/2004 (2004)
  6. NUREG-1601, “Chemical Process Safety at Fuel Cycle Facilities,” (1997)

Cited by

  1. Monte Carlo simulations of safeguards neutron counter for oxide reduction process feed material vol.69, pp.7, 2016, https://doi.org/10.3938/jkps.69.1175
  2. PRIDE 3D Simulator for Virtual Verification of Remote Handling Procedures in Processing Cell vol.15, pp.4, 2017, https://doi.org/10.7733/jnfcwt.2017.15.4.333
  3. Study on aluminum foam as a filler material for impact limiter of spent fuel transport cask vol.238, pp.2261-236X, 2018, https://doi.org/10.1051/matecconf/201823805006