Abstract
In this study, the static test of CFT truss girders for different f/L ratios was conducted to determine how the ultimate strength of the CFT truss girder was affected by different f/L ratios. A total of two CFT truss girders were constructed and tested under bending condition. The length of all specimens is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled circular tubes. The main parameter analyzed in the experimental study was the f/L ratio. This factor was experimentally investigated to assess their influence on ultimate strength and stiffness. The test results show that CFT truss girder has good elastic-plastic property and ductility. The presence of the f/L ratios in CFT truss girders alters its ultimate strength because of the global stiffness of the CFT truss girders. The ultimate strength of CFT truss girders increases as the f/L ratio increases. If the f/L ratio of the CFT truss girders increases twofold, the ultimate strengths increase by 80%. The CFT truss girders showed that they retained large deformation capacity, even after reaching the ultimate strength. Results of this investigation demonstrated the potential for efficiently using a CFT truss as a bridge girder.
본 연구에서는 f/L비가 CFT 트러스 거더의 극한강도에 미치는 영향을 평가하기 위하여 CFT 트러스 거더의 정적실험을 수행하였다. f/L비가 다른 2개의 CFT 트러스 거더를 제작하여 휨 실험을 수행하였다. CFT 트러스 거더의 지간은 20,000 mm이고, 상현재와 하현재는 콘크리트를 충전한 원형 강관 단면으로 구성되었다. 주요 실험변수인 f/L비가 극한강도와 강성에 미치는 영향을 평가하기 위하여 실험적 연구를 수행하였다. 실험결과, CFT 트러스 거더는 우수한 탄소성 특성과 연성능력을 보였고, f/L비는 CFT 트러스 거더의 전체 강성을 증가시켜 극한강도에 영향을 주는 것으로 나타났다. CFT 트러스 거더의 f/L비가 증가하면 극한강도가 증가하는데 f/L비가 2배 증가하면 극한강도는 약 80% 정도 증가하였다. 또한, CFT 트러스 거더는 극한강도에 도달한 이후에도 상당한 수준의 변형능력을 보여 주었다. 이상의 연구결과를 통해서 CFT 트러스 거더는 교량의 거더 부재로 효율적으로 적용 가능함을 확인하였다.