State of the Art of Imaging Equipment and Tools for Nuclear Cardiology

심장핵의학 검사를 위한 영상장비 및 도구의 최신동향

  • Lee, Byeong-Il (Department of Nuclear Medicine, Chonnam National Hawsun University Hospital)
  • Published : 2009.06.30

Abstract

Nuclear cardiology in Korea is less active, compared to nuclear oncology, but it has been specialized and ramified. Lately, sophisticated nuclear cardiac imaging methods provide more convenience for patients. It is necessary to accurately estimate the recent progress in the imaging devices for nuclear cardiology. Myocardial perfusion imaging is a well established study to evaluate heart function. Myocardial perfusion SPECT and PET have been used for assessment of coronary artery disease with various radiopharmaceuticals. And of late, the development of advanced imaging devices - multi-pinhole technique and high definition imaging technique - and software made the scanning time shorter and expanded the application field. Therefore, it is required to review the nuclear cardiology hardware/software for the clinical practice and research. In this review, the characteristics about recently-developed SPECT/PET and software for nuclear cardiology are described. It is hoped that this information would contribute to improving the activity of nuclear cardiac research in Korea where the research for the fusion imaging combining a and nuclear imaging is drawing more attention.

Keywords

References

  1. Keiichiro Y, Benjamin JC, Kathtyn W, Li C, Robert AD, Linda G, et al. What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Curdiol 2006;48:1029-39 https://doi.org/10.1016/j.jacc.2006.06.025
  2. Schelbert HR, Phelps ME, Huang SC, MacDonald NS, Hansen H, Selin C, et al. N-13 ammonia as an indicator of myocardial blood flow. Circulation 1981;63:1259-72 https://doi.org/10.1161/01.CIR.63.6.1259
  3. Hutchins GD, Schwaiger M, Rosenspire KC, Krivokapich J, Schelvert H, Kuhl DE. Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. Orculation 1992;86:1004-17
  4. Choi Y, Huang SC, Hawkins RA, Kuhle WG, Dahlbom M, Hoh CK, et al. A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET. J Nucl Med 1993;34:488-97
  5. Machac J. Cardiac positron emission tomography imaging. Semin Nucl Med 2005;35:17-36 https://doi.org/10.1053/j.semnuclmed.2004.09.002
  6. Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su H-T, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47
  7. Germano G, Erel J, Jewin H, Kavanagh PB, Berman DS. Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coli Cardiol 1997;30:1360-7 https://doi.org/10.1016/S0735-1097(97)00276-3
  8. Germano G, Kavanagh PB, Waechter P, Areeda J, Van Kriekinge S, Sharir T, et al. A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principle and reproducibility. J Nucl Med 2000;41:712-9
  9. Cuocolo A, Acampa W, Imbriaco M, De Luca N, Iovino GL, Salvatore M. The many ways to myocardial perfusion imaging. Nucl Med Mol Imaging 2005;49:4-18
  10. Travin MI, Heller GC, Johnson LL, Katten D, Ahlberg AW, Isasi CR, et al. The prognostic value of ECG-gated SPECT imaging in patients undergoing stress Tc-99m sestamibi myocardial perfusion imaging. J Nucl Curdiol 2004;11:253-62 https://doi.org/10.1016/j.nuclcard.2004.02.005
  11. James AP, David WT, Brian FH. Hybrid imaging technology: from dream and vision to clinical devices. Semin Nucl Med 2009;39:247-63 https://doi.org/10.1053/j.semnuclmed.2009.03.005
  12. Gambhir SS, Berman DS, Ziffer J, Nagler M, Sandler M, Patton J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43 https://doi.org/10.2967/jnumed.108.060020
  13. Frans H, Brendan V, Ruud MR, Woutjan B, Jens OK, Changguo J, et al. U-SPECT-II: An ultra-high-resolution device for molecular small-animal imaging. J Nucl Med 2009;50:599-605 https://doi.org/10.2967/jnumed.108.056606
  14. Emest VG, Tracy LF. New trends in camera and software technology in nuclear cardiology. Cardiol Clin 2009;27:227-36 https://doi.org/10.1016/j.ccl.2008.12.002
  15. Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63 https://doi.org/10.1016/j.jcmg.2007.12.004
  16. Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R, et al. Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc IMaging 2009;2:273-82 https://doi.org/10.1016/j.jcmg.2008.12.012
  17. Lee BI, Lee DS, Lee JS, Choi HK. Development of gated myocardial SPECT analysis software and evaluation of left ventricular contraction function. Korean J Nucl Med 2003;37:1-10
  18. Lee BI, Lee DS, Lee JS, Kang WJ, Chung J-K, Lee MC, et al. Development of evaluation method of regional contractility of left ventricle using gated myocardial SPECT and assessment of reproducibility. Korean J Nucl Med 2003;37:355-63
  19. Ali I, Ruddy TD, Almgrahi A, Anstett FG, Wells RG. Half-Time SPECT myocardial perfusion imaging with attenuation correction. J Nucl Med 2009;50:554-62 https://doi.org/10.2967/jnumed.108.058362
  20. DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC. Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection. J Nucl Cardiol 2008;15:547-63 https://doi.org/10.1016/j.nuclcard.2008.02.035
  21. Maddahi J, Mendez R, Mahmarian JJ, Thomas G, Babla H, Bai C, et al. Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imaging. J Nucl Cardiol 2009;16:351-7 https://doi.org/10.1007/s12350-009-9063-3
  22. Steele PP, Kirch DL, Koss JE. Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease. J Nucl Med 2008;49:1080-9 https://doi.org/10.2967/jnumed.107.040915
  23. Faber TL, Cooke CD, Folks RR, Vansant JP, Nichols KJ, DePuey EG, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999;40:650-9
  24. Bai W, Brady M. Regularized B-spline deformable registration for respiratory motion correction in PET images. Phys Med Biol 2009;54:2719-36 https://doi.org/10.1088/0031-9155/54/9/008
  25. Lamare F, Ledesma MJ, Cresson T, Kontaxakis G, Santos A, Le Rest CC, et al. List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations. Phys Med Biol 2007;52:5187-204 https://doi.org/10.1088/0031-9155/52/17/006
  26. Livieratos L, Rajappan K, Stegger L, Schafers K, Bailey DL, Camici PG. Respiratory gating of cardiac PET data in list-mode acquisition. Eur J Nucl Med Mol Imaging 2006;33:584-8 https://doi.org/10.1007/s00259-005-0031-0
  27. Fin L, Daouk J, Morvan J, Bailly P, El Esper I, Saidi L, et al. Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions. Eur J Nucl Med Mol Imaging 2008;35:1971-80 https://doi.org/10.1007/s00259-008-0858-2
  28. Santana CA, Garcia EV, Faber TL, Sirineni GK, Esteves FP, Sanyal R, et al. Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography. J Nucl Cardiol 2009;16:201-11 https://doi.org/10.1007/s12350-008-9019-z
  29. Slomka PJ, Le Meunier L, Hayes SW, Acampa W, Oba M, Haemer GG, et al. Comparison of myocardial perfusion 82Rb PET performed with CT- and transmission CT-based attenuation correction. J Nucl Med 2008;49:1992-8 https://doi.org/10.2967/jnumed.108.056580
  30. Henneman MM, Chen J, Dibbets-Schneider P, Stokkel MP, Bleeker GB, Ypenburg C, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med 2007;48:1104-11 https://doi.org/10.2967/jnumed.107.039925
  31. Lalonde L, Ziadi MC, Beanlands R. Cardiac positron emission tomography: current clinical practice. Cardiol Clini 2009;27:237-55 https://doi.org/10.1016/j.ccl.2008.12.003
  32. Wang F, Zhang J, Fang W, Zhao SH, Lu MJ, He ZX. Evaluation of left ventricular volumes and ejection traction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy. Eur J Nucl Med Mol Imaging 2009;Apr 18. Epub https://doi.org/10.1007/s00259-009-1136-7
  33. Petersen SE, Jung BA, Wiesmann F, Selvanayagam JB, Francis JM, Hennig S, et al. Myocardial tissue phase mapping with cine phase contrast MR imaging; regional wall motion analysis in healthy volunteers. Radiology 2006;238:816-26 https://doi.org/10.1148/radiol.2383041992
  34. Henneman MM, Chen J, Ypenburg C, Dibbets P, Bleeker GB, Boersma E, et al. Phase analysis of gated myocardial perfusion single-photon emission computed tomography compared with tissue doppler imaging for the assessment of left ventricular dyssynchrony. J Am Coll Cardiol 2007;49:1708-14 https://doi.org/10.1016/j.jacc.2007.01.063
  35. Nekolla SG, Martinez-Moeller A, Saraste A. PET and MRI in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging 2009;36(Suppl 1):S121-30 https://doi.org/10.1007/s00259-008-0980-1
  36. Goemig M, Haueisen J, Schreiber J, Leder U, Hanninen H, Makela T, et al. Comparison of current density viability imaging at rest with FDG-PET in patients after myocardial infarction. Comput Med Imaging Graph 2009;33:1-6 https://doi.org/10.1016/j.compmedimag.2008.09.002
  37. Helen S, Joey FU, Martin U, Hakan A, Einar H. An improved method for automatic segmentation of the left ventricle In myocardial perfusion SPECT. J Nucl Med 2009;50:205-13 https://doi.org/10.2967/jnumed.108.057323
  38. Serge VK, Hidetaka N, Muneo O, Daniel SB, Guido G. Automatic global and regional phase analysis from gated myocardial perfusion SPECT imaging: application to the characterization of ventricular contraction in patients with left bundle branch block. J Nucl Med 2008;49:1790-7 https://doi.org/10.2967/jnumed.108.055160
  39. Daniela K, Oliver HW, Philipp TM, Mardjan R, Thomas K, Karl-Christian K, et al. Gated myocardial perfusion SPECT: algorithm-specific influence of reorientation on calculation of left ventricular volumes and ejection traction. J Nucl Med 2008;49:1636-42 https://doi.org/10.2967/jnumed.108.050484
  40. Ankit C, Michele B, Riikka L, Corina V, Jennifer M, Frank MB. Comparison of measures of left ventricular function from electrocardiographically gated $^{82}$Rb PET with contrast-enhanced CT ventriculography: a hybrid PET/CT analysis. J Nucl Med 2008;49:1643-50 https://doi.org/10.2967/jnumed.108.053819
  41. Iskandrian AE, Garcia EV, Faber T, Mahmarian JJ. Automated assessment of serial SPECT myocardial perfusion images. J Nucl Cardiol 2009;16:6-9 https://doi.org/10.1007/s12350-008-9020-6
  42. Suzuki Y, Slomka PJ, Wolak A, Ohba M, Suzuki S, De Yang L, et al. Motion-frozen myocardial perfusion SPECT improves detection of coronary artery disease in obese patients. J Nucl Med 2008;49:1075-9 https://doi.org/10.2967/jnumed.108.050997