DOI QR코드

DOI QR Code

다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구

The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis

  • 김종보 (경기도보건환경연구원) ;
  • 정상진 (경기대학교 환경에너지시스템공학과)
  • Kim, Jong-Bo (Gyeonggi-do Institute of Health and Environment) ;
  • Jeong, Sang-Jin (Department of Environmental and Energy Systems Engineering, Kyonggi University)
  • 발행 : 2009.06.30

초록

We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

키워드

참고문헌

  1. The ministry of environment (Korea) : A handbook of odor control, 2-3, 2007
  2. The ministry of environment (Korea) : The method of odor examination, 2007
  3. Kim, J. B., Jeong, S. J., Song I. S. : The concentrations of sulfur compounds and sensation of odor in the residential area around Banwol-Sihwa industrial complex. Journal of Korean Society for Atmospheric Environment, 23(2), 147-157, 2007 https://doi.org/10.5572/KOSAE.2007.23.2.147
  4. Koe, L. C. C. : Hydrogensulphide odor in sewage atmospheres. Water Air Soil Pollution, 24, 297-306, 1985 https://doi.org/10.1007/BF00161789
  5. Gostelow, P., Parsons, S. A. : Sewage treatment works odour measurement. Water Science and Technology, 41(6), 33-40, 2000
  6. Kim, S. T., Park, M. S., Jun, Y. C., Kim, D. H., Hong, J. H. : A fundamental study of SOQ, odor unit and odor intensity interrelations for odor phenomenon evaluation. Proceeding of the 39th Meeting of KOSAE, 290-291, 2005
  7. Kim, M. G., Jung, Y. L., Park, J. J., Seo, Y. M., Yoon, I. K. : Evaluation method of odor-active compounds combine sensory method with instrumental analysis. Korean Journal of Odor Research and Engineering, 1(1), 31-38, 2002
  8. Kim, S. T., Park, M. S., Jun, Y. C., Kim, D. H., Hong, J. H. : An analysis between odor concentration quotient and odor concentration unit. Proceeding of the 38th Meeting of KOSAE, 270-271, 2004
  9. Kim, J. B., Jeong, S. J., Lee, J. P. : A study on the relatinship between odor unit and odorous compounds in the industrial complex. Proceeding of the 46th Meeting of KOSAE, 471-472, 2008
  10. Kim, J. B., Jeong, S. J. : A study on the relationship between odor unit and odorous compounds in industrial complex. Proceeding of the Korean Environmental Sciences Society Conference, Nov, 20-22, 134-137, 2008
  11. Heo, M. H., Seo, H. S. : SAS regression analysis, Free Academy Inc., 2001
  12. Kang, H. C., Choi, B. J., Kim, G. Y. : An introduction of SAS data analysis, Free Academy Inc., 2005
  13. Drew, G. H., Smith, R., Gerard, V., Burge, C., Lowe, M., Kinnersley, R., Sneath, R., Longhurst, P. J. : Appropriateness of selecting different averaging times for modelling chronic and acute exposure to environmental odours. Atmospheric Environment, 41, 2870-2880, 2007 https://doi.org/10.1016/j.atmosenv.2006.09.022