DOI QR코드

DOI QR Code

AN EXPERIMENTAL STUDY WITH SNUF AND VALIDATION OF THE MARS CODE FOR A DVI LINE BREAK LOCA IN THE APR1400

  • Lee, Keo-Hyoung (Department of Nuclear Engineering, Seoul National University) ;
  • Bae, Byoung-Uhn (Department of Nuclear Engineering, Seoul National University) ;
  • Kim, Yong-Soo (Korea Hydro & Nuclear Power Co.) ;
  • Yun, Byong-Jo (Korea Atomic Energy Research Institute) ;
  • Chun, Ji-Han (Department of Nuclear Engineering, Seoul National University) ;
  • Park, Goon-Cherl (Department of Nuclear Engineering, Seoul National University)
  • Published : 2009.06.30

Abstract

In order to analyze thermal hydraulic phenomena during a DVI (Direct Vessel Injection) line break LOCA (Loss-of-Coolant Accident) in the APR1400 (Advanced Power Reactor 1400 MWe), we performed experimental studies with the SNUF (Seoul National University Facility), a reduced-height and reduce-pressure integral test loop with a scaled down APR1400. We performed experiments dealing with eight test cases under varied tests. As a result of the experiment, the primary system pressure, the coolant temperature, and the occurrence time of the downcomer seal clearing were affected significantly by the thermal power in the core and the SI flow rate. The break area played a dominant role in the vent of the steam. For our analytical investigation, we used the MARS code for simulation of the experiments to validate the calculation capability of the code. The results of the analysis showed good and sufficient agreement with the results of the experiment. However, the analysis revealed a weak capability in predicting the bypass flow of the SI water toward the broken DVI line, and it was insufficient to simulate the streamline contraction in the broken side. We, hence, need to improve the MARS code.

Keywords

References

  1. Korea Hydro & Nuclear Power Co., Standard Safety Analysis Report for Advanced Power Reactor 1400, Seoul, Korea, 2002
  2. J. Liebert, R. Emmerling, “UPTF Experiment – Flow Phenomena during Full-scale Loop Seal Clearing of a PWR,” Nuclear Engineering and Design, vol. 179, pp. 51- 64, 1998 https://doi.org/10.1016/S0029-5493(97)00243-4
  3. Korea Atomic Energy Research Institute, “Best Estimate Small Break Loss of Coolant Analyses for Korean Next Generation Reactor with DVI ECCS,” KAERI/TR-1235/99, Daejon, Korea, 1999
  4. D. J. Euh, H. S. Park, K. Y. Choi, T. S. Kwon, W. P. Baek, “DVI-line break LOCA Analysis of The ATLAS-An Integral Effect Test Loop for Pressurized Water Reactors,” Proc. of the 11th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-11), Avignon, France, October 2-6, 2005
  5. B. J. Yun, C. H. Song, K. H. Min, H. K. Cho, G. C. Park, “Experimental Observations of the Hydraulic Phenomena in the APR-1400 Downcomer during the DVI Line Break Accident,” Korea Nuclear Society Spring Meeting, 2003
  6. Y. S. Kim, B. U. Bae, G. C. Park, K. Y. Suh, U. C. Lee, “Experiments and MAAP4 Assessment for Core Mixture Level Depletion after Safety Injection Failure during Long-Term Cooling of a Cold Leg LBLOCA,” Nuclear Engineering and Technology, vol.35, no. 2, pp. 91-107, 2003
  7. Y. S. Kim, B. U. Bae, C. H. Park, G. C. Park, K. Y. Suh, U. C. Lee, “RELAP5/MOD3.3 Analysis of Coolant Depletion Tests after Safety Injection Failure During a Large-Break Loss-of-Coolant Accident,” Nuclear Engineering and Design, vol. 235, pp. 2375-2390, 2005 https://doi.org/10.1016/j.nucengdes.2005.04.010
  8. B. U. Bae, K. H. Lee, Y. S. Kim, B. J. Yun, G. C, Park, “Scaling Methodology for a Reduced-height Reducedpressure Integral Test Facility to Investigate Direct Vessel Injection Line Break SBLOCA,” Nuclear Engineering and Design, vol. 238, pp. 2197-2205, 2008 https://doi.org/10.1016/j.nucengdes.2008.03.015
  9. J. J. Jeong et al., 'Development of a Multi-Dimensional Thermal-Hydraulic System Code, MARS 1.3.1. ,' Annals of Nuclear Energy, vol. 26(18),pp.1611-1642, 1999 https://doi.org/10.1016/S0306-4549(99)00039-0
  10. Nuclear Regulatory Commission, RELAP5 Code Manual, Bethesda, MD, USA, 1999
  11. M. J. Thurgood et al., COBRA/TRAC: A Thermalhydraulics Code for Transient Analysis of Nuclear Reactor Vessels and Primary Coolant Systems, USNRC Report, NUREG/CR-3046, 1983
  12. American Nuclear Society, Decay Heat Power in Light Water Reactors, ANSI/ANS 5.1-1979, LaGrange Park, IL, USA, 1979
  13. B. U. Bae, K. H. Lee, Y. S. Kim, B. J. Yun, J. H. Chun, G. C, Park, “An Integral Loop Test and MARS Code Analysis for a DVI Line Break LOCA in the APR1400,” Nuclear Engineering and Design, vol. 238, pp. 3336-3347, 2008 https://doi.org/10.1016/j.nucengdes.2008.06.018
  14. M. M. EL-WAKIL, Nuclear Heat Transport, The American Nuclear Society, La Grange Park, Illinois, USA, 1978
  15. B. J. Yun, H. K. Cho, D. J. Euh, C. H. Song, G. C. Park, “Scaling for the ECC bypass phenomena during the LBLOCA reflood phase,” Nuclear Engineering and Design vol. 231, pp. 315-325, 2004 https://doi.org/10.1016/j.nucengdes.2004.04.005
  16. Nuclear Regulatory Commission, RELAP5/MOD3.3 Code Manual Volume 1, Washington, DC, USA, 2001
  17. Korea Institute of Nuclear Safety, Development of Thermal Hydraulic Models for the Reliable Regulatory Auditing Code, KINS/HR-657, Daejon, Korea, 2004