References
- DenHartog, J.P. (1956), Mechanical Vibrations, Repr. 4th ed, McGraw-Hill, New York
- Fu, C. (2008), 'Effective damping of vibrations of plan-asymmetric buildings', Dissertation, Vienna University of Technology, Austria, http://www. tuwien.ac.at/
- Hitchcock, P.A., Kwok, K.C., Watkins, R.D. and Samali, B. (1997), 'Characteristics of liquid column vibration absorbers (LCVA)-II', Eng. Struct., 19, 135-144 https://doi.org/10.1016/S0141-0296(96)00044-2
- Hitchcock, P.A., Kwok, K.C., Watkins, R.D. and Samali, B. (1997), 'Characteristics of liquid column vibration absorbers (LCVA)-I', Eng. Struct., 19, 126-134 https://doi.org/10.1016/S0141-0296(96)00042-9
- Hochrainer, M.J. (2001), 'Control of vibrations of civil engineering structures with special emphasis on tall buildings', Dissertation, Vienna University of Technology, Austria, http://www. tuwien.ac.at/
- Hochrainer, M.J. and Ziegler, F. (2006), 'Control of tall building vibrations by sealed tuned liquid column dampers', Struct. Control Health Monitor., 13, 980-1002 https://doi.org/10.1002/stc.90
- Hochrainer, M.J. (2005), 'Tuned liquid column damper for structural control', Acta Mech., 175, 57-76 https://doi.org/10.1007/s00707-004-0193-z
- Lindner-Silvester, T. and Schneider, W. (2005), 'The moving contact line with weak viscosity effects – an application and evaluation of Shikhmurzaev's model', Acta Mech., 176, 245-258 https://doi.org/10.1007/s00707-004-0091-4
- MATLAB (2002), User Guide, Control Toolbox, MathWorks Inc., Version 6.5.1
- Reiterer, M. (2004), 'Damping of vibration-prone civil engineering structures with emphasis on bridges', Dissertation (in German), Vienna University of Technology, Austria, http://www. tuwien.ac.at/
- Reiterer, M. and Ziegler, F. (2004), 'Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers', J. Seismol. Earthq. Eng., 6(3), 45-60
- Reiterer, M. and Ziegler, F. (2006), 'Control of pedestrian-induced vibrations of long-span bridges', Struct. Control Health Monitor., 13, 1003-1027 https://doi.org/10.1002/stc.91
- Sakai, F., Takaeda, S. and Tamaki, T. (1989), 'Tuned liquid column damper-new type device for suppression of building vibration', Proc. Int. Conf. on High-rise Buildings, Nanjing, China, 926-931
- Ziegler, F. (1998), Mechanics of Solids and Fluids, corr. Repr. 2nd ed. Springer, New York
- Ziegler, F. and Fu, C. (2007), 'Effective vibration damping of plan-asymmetric buildings', Proc. of the 8th Int. Conf. on Multi-purpose High-rise Towers and Tall Buildings (Sabouni, A.-R.R., El-Sawy, K.M., eds.), The International Federation of High-Rise Structures. Abu Dhabi. CD-Rom Paper ID IFHS-039, 1-13. (www.acevents.ae 'online documents'_ifhs2007+ifhs2007dxb _TB-28.pdf)
Cited by
- Effects of coordinated crowd motion on dynamic responses of composite floors in buildings vol.6, pp.1, 2013, https://doi.org/10.1080/19373260.2013.738522
- Active TLCGD control of plane asymmetric buildings under earthquake excitation vol.27, pp.5, 2011, https://doi.org/10.1007/s10409-011-0504-2
- Vibration Control of Plan-Asymmetric Buildings Using Active TLCGD vol.163-167, pp.1662-8985, 2010, https://doi.org/10.4028/www.scientific.net/AMR.163-167.3461
- Inelastic design of high-axially loaded concrete columns in moderate seismicity regions vol.39, pp.4, 2009, https://doi.org/10.12989/sem.2011.39.4.559
- Ambient vibration tests on a 19 - story asymmetric steel building vol.40, pp.1, 2011, https://doi.org/10.12989/sem.2011.40.1.001
- Concurrent flexural strength and deformability design of high-performance concrete beams vol.40, pp.4, 2009, https://doi.org/10.12989/sem.2011.40.4.541