Abstract
An objective of this study is to evaluate the structural performance of the weak axis SRC column-RC beam joints by experiments. Although one of common joint types is the connection with standard hooks, it has been required to examine its safety and to settle problems of the joint among practical engineers. Specimen types are classified into two categories, namely the type of standard hook and the type of shape improvement. The first one is consisted of three specimens which are reference type, development length modification type, and development length supplement type. Three specimens for shape improvement were made with variations on the arrangement of longitudinal reinforcements and the development length. Test results based on cyclic loadings were discussed with load-deflection curves, maximum strengths, strength degradations beyond the maximum. It was found that the standard hook types showed premature failures and consequent strength degradations due to splitting of joint concrete. However, satisfactory performance was obtained with the shape improvement type with wing-plate welding. No premature failures and strength degradations were detected with the specimens.
본 연구는 SRC기둥-RC보 약축방향 접합부에 대한 구조성능 평가 실험 연구이다. 현재 국내현장에서 많이 사용하고 있는 약축방향 접합방식은 구조성능이 명확하게 규명되지 않은 방식이 많으며, 이에 대한 안전성 확보 여부의 검증 및 문제점에 대한 개선도 시급하다. 따라서 본 연구에서는 표준갈고리형 실험체 3개와 접합부 형상 개선 실험체 3개 등 총 6개의 실험체를 제작하였다. 표준갈고리형 실험체들은 기준실험체, 정착길이 보정 실험체, 쉬어코넥터 및 전단보강근에 의한 보강 실험체 등으로 구성되어 있다. 접합부 형상 개선 실험체들은 주철근배치 방식과 용접 그리고 정착길이 확보 실험체 등이다. 반복가력에 의한 실험을 통하여 하중-변위 곡선, 최대강도, 강도저감 등을 평가하였다. 실험결과, 표준갈고리형 실험체들은 RC보의 주철근이 기둥면 내 콘크리트를 물고 떨어지는 쪼개짐 파괴현상을 나타내었으며, 구조성능도 불량하였다. 그러나 새로운 접합부 형상 개선 실험체들은 표준갈고리형 실험체들과 같이 기둥면 내콘크리트를 물고 떨어지는 쪼개짐 파괴현상도 나타나지 않았으며, 구조성능도 양호하였다.