DOI QR코드

DOI QR Code

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min (Department of Environmental Health Science, Soonchunhyang University) ;
  • Jang, Seong-Ki (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Yang, Won-Ho (Department of Occupational Health, Catholic University of Daegu) ;
  • Cho, Tae-Jin (Department of Environmental Health Science, Soonchunhyang University) ;
  • Son, Bu-Soon (Department of Environmental Health Science, Soonchunhyang University)
  • Published : 2009.05.31

Abstract

Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

Keywords

References

  1. Park J. C., 2005, A measurement of Formaldehyde and Volatile Organic Compounds in newly-constructed apartment house, M.S, Department of Architecture, The Graduate School of Chung-Ang University, Seoul
  2. Kim S. D., Kim T. S., Lee H. K., Lee J. J., 1993, The spatial characteristics of ventilation efficiency, Journal of Korea Air Pollution Research Association 9(3), 236-241
  3. Ministry of Environment, 2004, Indoor Air Quality Process Test Methods
  4. Jo J. J., 2004, Surveys of the concentration of VOCS at measurement sites in new apartment, Proceeding of the 37th Meeting of Korean Society for Atomospheric Environment, 201-202
  5. Jeon H. J., A source identification and characteristics of Volatile Organic Compounds(VOCs) and Formaldehyde in apartment housing, M.S., Department of Environmental Engineering, The Graduate School of Engineering, Hanyang University, Seoul
  6. National Institute of Environmental Research, 2004, A survey of the indoor air quality in new apartments in Korea
  7. Uchiyama S. etc 2, 2001, A source identification of Volatile Organic Compounds in new apartment, Japan Construction Academic Society thesis, 547
  8. Kim J. C., 2005, An application of risk assessment for establishment of the standard of HAPs in new/old apartment, M.S, Department of Environmental Engineering(Air Pollution Control), The Graduate School of Engineering, Hanyang University, Seoul
  9. Risk K., 1995, Volatile organic compounds in the indoor air of normal and sick house, Atmospheric environment, 29(6), 693-702 https://doi.org/10.1016/1352-2310(94)00309-9
  10. Michael R. etc, 2001, Volatile Organic Compound, Poly cyclic Aromatic Hydrocarbons and Elements in the Air of Ten Urban Homes, Indoor Air, 11, 49-64 https://doi.org/10.1034/j.1600-0668.2001.011001049.x
  11. Lee S. M., Kang D. S., Kang S. J., Sohn J. Y., 1998, Air exchange rates and Indoor Air Quality levels of hugh-rise apartments in winter, Journal of the Society of Living Environment System, 5(2), 9-14

Cited by

  1. Effect of Mechanical Ventilation System on Improvement of Indoor Air Quality in A Newly Built Apartment and B Department Store vol.24, pp.1, 2014, https://doi.org/10.15269/JKSOEH.2014.24.1.038