Analysis of the Critical Path of Underground Gas Pipe According to Interference Behavior

간섭 거동에 따른 지하 가스 배관의 영향선 분석

  • Published : 2009.04.30

Abstract

In order to make the critical path analysis of gas pipeline located under rigid pipes for interference behavior, FE analysis is performed considering real buried conditions of a drain and a gas pipe according to intersection angle of two pipes. A drain pipe and gas pipe have cover depth respectively 1.0m and 3.39m and this study considers a interference angle in the range of $0{\sim}90^{\circ}$. In this paper, the critical path is analyzed from the result of Ring Deflection and bending stress according to intersection angle. In the event intersection angle of two pipes equal to the critical path of lower pipe. The analysis results show that the critical path of lower gas pipe according to interference behavior has relation to intersection angle of two pipes.

관망 내 배관의 간섭 거동에 따른 지하 매설 배관의 영향선 분석을 위하여 실제 환경에 부합 하도록 지하의 상부와 하부에 각각 하수관거와 가스관을 매설하여 유한요소모델을 구현하였으며, 두 배관의 교차 정도에 따라 하부 가스 배관의 영향선을 분석하였다. 하수관거와 가스관은 각각 1.0m와 3.39m의 매설심도를 가지며, 두 배관이 이루는 교차각은 $0{\sim}90^{\circ}$에 대하여 해석을 실시하였다. 본 연구에서는 Ring Deflection과 Bending Stress의 결과로부터, 교차각에 따른 영향선을 분석하였으며, 그 결과 두 배관이 이루는 교차각과 하부 배관의 영향선은 일치함을 알 수 있었다. 따라서 배관의 간섭 거동에 따른 하부 배관의 영향선은 두 배관의 교차각과 깊은 관계가 있다고 판단된다.

Keywords

References

  1. 정성교, 옥치남, 장기태, “매설흄관의 설계하중 결정에 관한 연구”, 대한토질공학회지, 제 5권, 제 2호, 1989년 1월, (1989)
  2. 한국토지공사, “파형강관을 이용한 하수관거의 설계 및 시공법 연구”, (2004)
  3. 한국가스공사, “한국가스공사 표준 주배관 매설심도 설계기준”, (2003)
  4. Reynold King Watkins and Loren Runar Anderson, “Structural mechanics of buried pipes”, CRC Press, (2000)