References
- Belardinelli, E., M. Ursino and E. Iemmi, 1989, A preliminary theoretical study of arterial pressure perturbations under shock acceleration, J. Biomech. Eng.-Trans. ASME 111, 233-240 https://doi.org/10.1115/1.3168372
- Buchanan Jr, J. and C. Kleinstreuer, 1998, Simulation of particlehemodynamics in a partially occluded artery segment with implications to the initiation of microemboli and secondary stenoses, J. Biomech. Eng.-Trans. ASME 120, 446-454 https://doi.org/10.1115/1.2798013
- Burton, R. R., S. D. Leverett Jr and E. D. Michaelson, 1974, Man at high sustained +G(z) acceleration: a review, AEROSPACE MED. 45, 1115-1136
- Chien, S., 1982, Hemorheology in clinical medicine, Clin. Hemorheol. 2, 137-142
- Cho, Y. I., L. H. Back and D. W. Crawford, 1985, Experimental investigation of branch flow ratio, angle, and Reynolds number effects on the pressure and flow fields in arterial branch models, J. Biomech. Eng.-Trans. ASME 107, 257-267 https://doi.org/10.1115/1.3138551
- Deplano, V. and M. Siouffi, 1999, Experimental and numerical study of pulsatile flows through stenosis: Wall shear stress analysis, J. Biomech. 32, 1081-1090 https://doi.org/10.1016/S0021-9290(99)00098-6
- Fry, D., 1972, Response of the arterial wall to certain physical factors. Atherogenesis: Initiating factors, A Ciba Foundation Symp., 40-43
-
Gijsen, F. J. H., E. Allanic, F. N. Van De Vosse and J. D. Janssen, 1999, The influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90
${^{\circ}}$ °curved tube, J. Biomech. 32, 705-713 https://doi.org/10.1016/S0021-9290(99)00014-7 - Hooks, L., R. Nerem and T. Benson, 1972, A momentum integral solution for pulsatile flow in a rigid tube with and without longitudinal vibration, Int. J. Eng. Sci. 10, 989-1007 https://doi.org/10.1016/0020-7225(72)90021-3
- Imao, S., M. Itoh, Y. Yamada and Q. Zhang, 1992, The characteristics of spiral waves in an axially rotating pipe, Exp. Fluids 12, 277-285
- Kikuyama, K., M. Murakami, K. Nishibori and K. Maeda, 1983, Flow in an Axially Rotating Pipe: A calculation of flow in the saturated region, B. JSME. 26, 506-513
- Luo, J. Y., R. I. Issa and A. D. Gosman, 1994, Prediction of impeller-induced flows in mixing vessels using multiple frames of reference, IChemE Symp. Ser. 136, 549-556
- Luo, X. and Z. Kuang, 1992, Non-Newtonian flow patterns associated with an arterial stenosis, J. Biomech. Eng.-Trans. ASME 114, 512-514 https://doi.org/10.1115/1.2894103
- Mandal, P. K., S. Chakravarty, A. Mandal and N. Amin, 2007, Effect of body acceleration on unsteady pulsatile flow of nonnewtonian fluid through a stenosed artery, Appl. Math. Comput. 189, 766-779 https://doi.org/10.1016/j.amc.2006.11.139
- Misra, J. C. and B. K. Sahu, 1988, Flow through blood vessels under the action of a periodic acceleration field. A mathematical analysis, J. Comput. Appl. Math. 16, 993-1016 https://doi.org/10.1016/0898-1221(88)90256-8
- Nakamura, M. and T. Sawada, 1988, Numerical study on the flow of a non-Newtonian fluid through an axisymmetric stenosis, J. Biomech. Eng.-Trans. ASME 110, 137-143 https://doi.org/10.1115/1.3108418
- Ro, K. C., S. H. Lee, S. W. Cho and H. S. Ryou, 2008, Numerical Study on Blood Flow Characteristics of the Stenosed Blood Vessel with Periodic Acceleration and Rotating Effect, Springer Proceedings in Physics Series 124, 77-83 https://doi.org/10.1007/978-3-540-85190-5_7
- Tang, D., C. Yang and D. N. Ku, 1999, A 3-D thin-wall model with fluid-structure interactions for blood flow in carotid arteries with symmetric and asymmetric stenoses, Comput. Struct. 72, 357-377 https://doi.org/10.1016/S0045-7949(99)00019-X
- Young, D. F., 1968, Effect of a time dependent stenosis on flow through a tube, J. Engng. Ind. Trans. ASME 90, 248-254 https://doi.org/10.1115/1.3604621
- Young, D. F., 1979, Fluid mechanics of arterial stenoses, J. Biomech. Eng.-Trans. ASME 101, 157-175 https://doi.org/10.1115/1.3426241