Seismic Safety Analysis of Intake Tower with Hollow Inside Section

중공 단면을 갖는 취수탑의 내진 안전성 평가

  • Bae, Jung-Joo (Korea Infrastructure Safety and Technology Corporation) ;
  • Kim, Yon-Gon (Department of Safety Engineering, Hankyong National University) ;
  • Lee, Jee-Ho (Department of Civil and Environmental Engineering, Dong-guk University) ;
  • Han, Sang-Hoon (Department of Civil Engineering, Chungbuk National University)
  • Published : 2009.04.30

Abstract

Seismic Safety Analysis of Intake Tower is very important because failure of intake tower may incur huge chaos on the modem society. Recently, there has been growing much concern about earthquake resistance of existing structures. This research demonstrates the dynamic fluid pressure calculation using added mass simulation. The actual safety evaluation has been conducted through not only the static analysis but also the dynamic analysis. According to the analysis results, the vibration incurred by earthquake may induce considerable damage to the hydraulic structure. Therefore, the appropriate design process out of exact calculation is quite necessary.

Keywords

References

  1. 건설교통부, 기존 댐의 내진성능 평가 및 향상요령, 2004
  2. 한국콘트리트학회, 콘크리트 구조설계기준, 2007
  3. 건설교통부, 댐 설계기준, 2005
  4. 건설교통부, 기존 댐의 내진성능 평가 및 향상 요령, 2004
  5. 김용곤,'동수압을 고려한 콘크리트 중력식 댐의 내진 안전성 평가', 한국안전학회지, 제21권, 제1호, pp.120-132, 2006
  6. 환경부, 상수도 시설 내진설계기준마련을 위한 연구, 1999