Reference dose levels for dental panoramic radiography in Anyang City

안양시에서 치과용 파노라마방사선사진의 참고 선량 수준

  • Kim, Young-Hee (Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital) ;
  • Lee, Jae-Seo (Department of Oral and Maxillofacial Radiology, Chonnam National University Hospital, School of Dentistry, Chonnam National University) ;
  • Yoon, Suk-Ja (Department of Oral and Maxillofacial Radiology, School of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Kang, Byung-Cheol (Department of Oral and Maxillofacial Radiology, School of Dentistry, Dental Science Research Institute, Chonnam National University)
  • Published : 2009.12.31

Abstract

Purpose : To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Materials and Methods : Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. Results : The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. Conclusion : The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipments.

Keywords

References

  1. White SC, Pharoah MJ. Oral radiology: principles and interpretation. 5th ed. St. Louis: Mosby; 2004.
  2. Gibbs SJ. Effective dose equivalent and effective dose: comparison for common projections in oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 90 : 538-45. https://doi.org/10.1067/moe.2000.109189
  3. Farman TT, Farman AG, Kelly MS, Firriolo FJ, Yancey JM, Stewart AV. Charge-coupled device panoramic radiography: effect of beam energy on radiation exposure. Dentomaxillofac Radiol 1998; 27 : 36-40. https://doi.org/10.1038/sj.dmfr.4600316
  4. NRPB. Guidance noted for dental practicioners on the safe use of X-ray equipment. NRPB, Department of Health, Chilton, UK: NRPB, 2001.
  5. International Atomic Energy Agency (IAEA). International basic safety standards for projection against ionizing radiation and for the safety of radiation sources. Safety Series No. 115. Vienna, 1996.
  6. International Commission on Radiological Protection: Radiation protection, ICRP Publ. 60, Oxford, England, 1990.
  7. NCRP Report No. 145, Radiation protection in dentistry, 2003.
  8. Napier ID. Reference doses for dental radiography. Br Dental J 1999; 186 : 392-6.
  9. Doyle P, Martin CJ, Robertson J. Techniques for measurement of dose width product in panoramic dental radiography. Br J Radiol 2006; 79 : 142-7. https://doi.org/10.1259/bjr/33207232
  10. Williams JR, Montgomery A. Measurement of dose in panoramic dental radiology. Br J Radiol 2000; 73 : 1002-6.
  11. Isoardi P, Ropolo R. Measurement of dose-width product in panoramic dental radiology. Br J Radiol 2003; 76 : 129-31. https://doi.org/10.1259/bjr/58851704
  12. Faulkner D, Corbett RH. Reference doses and quality in medical imaging. Br J Radiol 1998; 71 : 1001-2. https://doi.org/10.1259/bjr.71.850.10211057
  13. UNSCEAR 2000 Report to the General Assembly, with scientific annexes. p. 306, 388.
  14. Poppe B, Looe HK, Pfaffenberger A, Chofor N, Eenboom F, Serign M, et al. Dose-area product measurements in panoramic dental radiology. Radiat Prot Dosim 2007; 123 : 131-4. https://doi.org/10.1093/rpd/ncl090
  15. CRCPD. Patient exposure and dose guide-2003. CRCPD Publication E-03-2.
  16. Yakoumakis EN, Tierris CE, Stefanou EP, Phanourakis IG, Proukakis CC. Image quality assessement and radiation doses in intraoral radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001; 91 : 362-8. https://doi.org/10.1067/moe.2001.111940