Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of Water-back-flushing Time and Period

세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 물 역세척 시간 및 주기의 영향

  • Park, Jin-Yong (Department of Environmental Sciences & Biotechnology, Hallym University) ;
  • Lee, Hyuk-Chan (Department of Environmental Sciences & Biotechnology, Hallym University)
  • 박진용 (한림대학교 환경생명공학과) ;
  • 이혁찬 (한림대학교 환경생명공학과)
  • Published : 2009.03.30

Abstract

In this study, we used the hybrid module that was composed of granular activated carbons (GAC) packing between module inside and outside of tubular ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, modified solution was prepared with humic acid and kaolin. We were investigated effect of water-back-flushing time (BT) and water-back-flushing period (FT) to minimize membrane fouling and to enhance permeate flux (J) in the hybrid process, and tried to find the optimal operating conditions. As a result, resistance of membrane fouling ($R_f$) was slightly decreased according to increasing BT. Also, the shorter FT was the more effective to reduce $R_f$ and to enhance J because of frequent water-back-flushing. However, the optimal BT and FT conditions were 10 sec and 8 min respectively when operating costs were considered. Then, the optimal conditions derived from our experiments of modified solution were applied to lake water treatment. As a result, average treatment efficiencies of turbidity, $UV_{254}$ absorbance, and $COD_{Mn}$ were very high as 99.11%, 91.40% and 89.34%, respectively, but that of TDS was low as 30.05%.

본 연구에서는 고도정수처리를 위하여 모듈 내부와 관형 세라믹 정밀여과막 외부 사이의 공간에 입상 활성탄(GAC)을 충전한 혼성 모듈을 사용하였다. 정수 원수 중의 자연산 유기물(NOM)과 미세 무기 입자를 대체하기 위해, 휴믹산(humic acid)과 카올린(kaolin) 모사용액을 대상으로 하였다. 혼성공정에서 막오염을 최소화하고 투과선속(J)을 향상시키기 위하여 역세척 시간(BT)과 역세척 주기(FT)에 따른 영향을 알아보았으며, 최적운전조건을 규명하고자 하였다. 그 결과, BT가 증가함에 따라 $R_f$ 다소 감소하는 경향을 보였으며, 더 짧은 FT는 빈번한 역세척으로 $R_f$의 감소와 J의 향상에 더 효과적이었다. 그러나 운전비용을 고려하였을 때, 최적 BT 및 FT는 각각 10초와 8분이었다. 한편, 모사용액으로 실험하여 도출된 최적 운전조건을 호소수의 고도정수처리에 적용하였다. 그 결과, 탁도 및 $UV_{254}$ 흡광도, $COD_{Mn}$의 평균처리효율은 각각 99.11% 및 91.40%, 89.34%로 우수하였으나, TDS의 평균처리효율은 30.05%로 낮았다.

Keywords

References

  1. 박재충, 박정원, 신재기, 이희무, '인공호에서 몬순과 태풍강우에 의한 고탁수층의 이동과 소멸특성', 한국하천호수학회지, 38(1), 105 (2005)
  2. 신재기, 강창근, 황순진, '팔당호에서 수중탁도의일 변동과 고탁수의 입자분포', 한국하천호수학회지, 36(3), 257 (2003)
  3. 신재기, 허진, 이홍수, 박재충, 황순진, '표층수를 방류하는 저수지(용담호)에서 몬순 탁수환경의 공간적 해석', 한국물환경학희지, 22(5), 933 (2006)
  4. 박진용, '세라믹 여과 시스템으로 제지폐수 처리시 회수 효율에 대한 물 역세척 시간의 영향' 멤브레인 14(4), 329 (2004)
  5. 박지혜, 이상윤, 박흥석, '개질 Clay를 첨가한 응집 공정에서의 자연유기물 제거', 상하수도학회지 21(1), 37 (2007)
  6. M. H. Cho, C. H. Lee, and S. H. Lee, 'Effεct of flocculation conditions on membrane permeability in coagulation-microfiltration', Desalination, 191 , 386 (2006) https://doi.org/10.1016/j.desal.2005.08.017
  7. Y. Yoon and R. M. Lueptow, 'Removal of organic contaminants by RO and NF membranes', J Membr. Sci., 261, 76 (2005) https://doi.org/10.1016/j.memsci.2005.03.038
  8. M. R. Teixeira and M. J. Rosa, 'The impact of the water background inorganic matrix on the natural organic matter removal by nanofiltration', J Membr. Sci. , 279, 513 (2006) https://doi.org/10.1016/j.memsci.2005.12.045
  9. 정지현, 추광호, 박학순, '저압 막여과 혼성공정을 이용한 고도 정수처리' 멤브레인, 17(3), 161 (2007)
  10. H. S. Kim, S. Takizawa, and S. Ohgaki, 'Application of microfiltration systems coupled with powdered activat$\varepsilon$d carbon to riv$\varepsilon$r treatment', esalination, 202, 271 (2007) https://doi.org/10.1016/j.desal.2005.12.064
  11. S. Mozia and M. Tomaszewska,'reatm$\varepsilon$nt of surface water using hybrid processes-adsorption on PAC and ultrafiltration' Desalination, 162, 23 (2004) https://doi.org/10.1016/S0011-9164(04)00023-2
  12. R. H. S. Jansen, W. de Rijk, A. Zwijnenburg, M. H. V. Mulder, and M. Wessling, 'Hollow fiber membrane contactors - A means to study the reaction kinetics of humic substance ozonation', J Membr. Sci., 257, 48 (2005) https://doi.org/10.1016/j.memsci.2004.07.038
  13. 박경원, 추광호, 김문현, '광촉매 반응과 침지형 정밀여과를 이용한 자연산 유기물의 제거', 멤브레인 14(2), 149 (2004)
  14. 이용택, 오중교, '분리막을 이용한 정수처리공정에서 유, 무기물질이 막오염에 끼치는 영향', 멤브레인 13(4), 219 (2003)
  15. W. Yuan, A. Kocic, and A. L. Zydney, 'Analysis of humic acid fouling during microfiltration using a pore blockage-cake filtration model', J Membr. Sci. , 198, 51 (2002) https://doi.org/10.1016/S0376-7388(01)00622-6
  16. D. B. Mosqueda-Jimenez and P. M. Huck, 'Characterization of membrane foulants in drinking water treatmεnt', Desalination, 198, 173 (2006) https://doi.org/10.1016/j.desal.2005.12.025
  17. M. Heran and S. Elmaleh, 'Microfiltration through an inorganic tubular membrane with high frequency retrofiltration', J Membr. Sci., 188, 181 (2001) https://doi.org/10.1016/S0376-7388(01)00351-9
  18. S. K. Karode, 'Unsteady state flux response: a method to determine the nature of the solute and gel layer in mambrane filtration', J Membr. Sci. ,188, 9 (2001) https://doi.org/10.1016/S0376-7388(00)00644-X
  19. H. K. Vyas, A. J. Mawson, R. J. Bennett, and A. D. Marshall, 'A new method for estimationg cake height and porosity during filtration of particulate suspensions', J Membr. Sci. , 176, 113 (2000) https://doi.org/10.1016/S0376-7388(00)00437-3
  20. P. Rai, C. Rai, G. C. Majumdara, S. D. Gupta, and S. De, 'Resistance in series model for ultrafiltration of mosambi (Citrus sinensis (L.) Osbeck) JUlce in a stirred continuous mode', J Membr. Sci. , 283, 116 (2006) https://doi.org/10.1016/j.memsci.2006.06.018
  21. K. Katsoufidou, S. G. Yiantsios, and A. J. Karabelas, 'A study of ultrafiltration membrane fouling by humic acids and flux recovery by back washing: Experiments and modeling', J Membr. Sci., 266, 40 (2005) https://doi.org/10.1016/j.memsci.2005.05.009
  22. J. Y. Park, S. J. Choi, and B. R. Park, 'Effect of $N_2$-back-flushing in multichannels ceramic microfiltration system for paper wastewater treatrnent', Desalination, 202, 207 (2007) https://doi.org/10.1016/j.desal.2005.12.056
  23. D. Chen, L. K. Weavers, and H. W. Walker, 'Ultrasonic control of ceramic membrane fouling: Effect of particle characteristics', Water research, 40, 840 (2006) https://doi.org/10.1016/j.watres.2005.12.031
  24. 육영재, 염경호, '초음파를 이용한 한외여과의 성능 향상', 멤브레인 13(4), 283 (2003)
  25. W. F. Jones, R. L. Valentine, and V. G. J. Rodgers, 'Removal of suspended clay from water using transmembrane pressure pulsed microfiltration', J Membr. Sci. , 157, 199 (1999) https://doi.org/10.1016/S0376-7388(98)00376-7
  26. F. Malek, J. L. Harris, and F. A. Roddick, 'Interrelationship of photooxidation and microfiltration in drinking water treatment', J Membr. Sci. , 281, 541 (2006) https://doi.org/10.1016/j.memsci.2006.04.045
  27. 이혁찬, 박진용, '세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리· 입상 활성탄 충전율에 의한 영향', 멤브레인 18(3), 191 (2008)
  28. 윤경은, '입상활성탄과 오존/입상활성탄을 이용한 한강본류 원수의 NOM 제거특성', 서울시립대학교,석사학위 논문 (2007)
  29. 정진영, 강길윤, 윤동현, 김윤성, 서근학, 임준혁, '활성탄에 의한 상수원수중 NOM의 흡착특성에 관한 연구', 공업화학, 14(8), 1127 (2003)
  30. 동화기술편집부, '수질오염 공정시험방법', 동화기술, pp. 129-130 (1996)
  31. M. Cheryan, 'Ultrafiltration Handbook', Technomic Pub. Co., Lancater, PA, pp. 89-93 (1984)