Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator

Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구

  • Lee, Se-Hyung (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan) ;
  • Park, Sung-Ho (Department of Radiation Oncology, Asan Medical Center, College of Medicine, University of Ulsan) ;
  • Seo, Hee (Department of Nuclear Engineering, Hanyang University) ;
  • Park, Jin-Hyung (Department of Nuclear Engineering, Hanyang University) ;
  • Kim, Chan-Hyeong (Department of Nuclear Engineering, Hanyang University) ;
  • Lee, Ju-Hahn (Department of Physics, Chungang University) ;
  • Lee, Chun-Sik (Department of Physics, Chungang University) ;
  • Lee, Jae-Sung (Department of Nuclear Medicine and Interdisciplinary Program in Radiation Applied Life Science, Seoul National University)
  • 이세형 (울산대학교 의과대학 서울아산병원 방사선종양학과) ;
  • 박성호 (울산대학교 의과대학 서울아산병원 방사선종양학과) ;
  • 서희 (한양대학교 원자력공학과) ;
  • 박진형 (한양대학교 원자력공학과) ;
  • 김찬형 (한양대학교 원자력공학과) ;
  • 이주한 (중앙대학교 물리학과) ;
  • 이춘식 (중앙대학교 물리학과) ;
  • 이재성 (서울대학교 핵의학교실)
  • Published : 2009.06.30

Abstract

A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

컴프턴 카메라는 컴프턴 산란현상의 기하학적 해석을 통해 감마선원의 3차원적 위치분포를 고정된 위치에서 찾아내는 신개념의 감마선 영상장치이다. 기존의 감마선 영상장치에서는 필수적으로 사용되는 기계적 집속기를 사용하지 않기 때문에 높은 영상 감도를 제공할 수 있으며, 다중 추적자 기능을 제공한다는 장점이 있어 차세대 감마선 영상장치로서 주목을 받고 있다. 본 연구에서는 Geant4 몬테칼로 전산모사 툴키트를 이용하여 사용자 친화형의 컴프턴 카메라 시뮬레이터를 개발하였다. 시뮬레이터의 정확성을 검증하기 위하여 한양대학교에서 개발 중인 이중 산란형 컴프턴 카메라의 실험 결과와 비교하였다. 영상 해상도의 경우 선원의 에너지가 높아짐에 따라 해상도가 향상되는 동일한 경향을 보였으나, 시뮬레이터 결과에서 약 1 mm 정도 우수하게 평가되었다. 영상 감도의 경우 실험에서 2~3배 정도 높게 평가되었다. 이러한 결과들은 우연 동시반응에 기인한 것으로, 실험에서 획득한 유효반응들은 전산모사와는 달리 우연한 동시계수에의한 데이터가 상당수 포함되어 있기 때문에 영상 해상도는 상대적으로 저조하고, 영상 감도는 높게 나타난 것으로 판단된다. 개발된 시뮬레이터를 이용하여 새로운 구조의 컴프턴 카메라에 대한 성능을 평가하였다. 단일 산란형 컴프턴 카메라의 경우 산란부를 다층 구조로 개발할 때 4대의 산란부 검출기를 사용하는 것이 최상의 성능을 보이는 것으로 평가되었고, 그 이상 사용할 경우 성능이 오히려 저하됨을 확인하였다.

Keywords

References

  1. Todd RW, Nightingale JM, Everett DR: A proposed gamma camera. Nature 251:132-134 (1974) https://doi.org/10.1038/251132a0
  2. Singh M: An electronically collimated gamma camera for single photon emission computed tomography. Part I. Theoretical Considerations and Design Criteria. Med Phys 10:421-427 (1983) https://doi.org/10.1118/1.595313
  3. Llosa G, Bernabeu J, Burdette D, et al: Last results of a first compton probe demonstrator. IEEE Trans Nucl Sci 55: 936-941 (2008) https://doi.org/10.1109/TNS.2008.922817
  4. Leblanc JW, Clinthorne NH, Hua CH, et al: C-SPRINT: A prototype compton camera system for low energy gamma ray imaging. IEEE Trans Nucl Sci 45:943-949 (1998) https://doi.org/10.1109/23.682679
  5. Watanabe S, Tanaka T, Watanabe S, et al: Performance study of Si/CdTe semiconductor compton telescopes with monte carlo simulation. Nucl Instr and Meth A 579:878-885 (2007) https://doi.org/10.1016/j.nima.2007.05.293
  6. Kabuki S, Hattori K, Kohara R, et al: Development of electron tracking compton camera using micro pixel gas chamber for medical imaging. Nucl Instr and Meth A 580:1031-1035 (2007) https://doi.org/10.1016/j.nima.2007.06.098
  7. Vetter K, Burks M, Cork C, et al: High-sensitivity compton imaging with position-sensitive si and ge detectors. Nucl Instr and Meth A 591:363-366 (2007)
  8. Wulf EA, Phlips BF, Johnson WN, et al: Compton imager for detection of special nuclear material. Nucl Instr and Meth A 579:371-374 (2007) https://doi.org/10.1016/j.nima.2007.04.085
  9. Du YF, He Z, Knoll GF, Wehe DK, Li W: Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors. Nucl Instr and Meth A 457:203-211 (2001) https://doi.org/10.1016/S0168-9002(00)00669-0
  10. Seo H, An SH, Kim JK, Kim CH: Monte carlo study of a double scattering compton camera with GEANT4. Nucl Instr and Meth A 580:314-317 (2007) https://doi.org/10.1016/j.nima.2007.05.164
  11. Lee JH, Kim NY, Lee CS, Jang ZH: Development of the multi-purpose gamma-ray detection system consisting of a double- sided silicon strip detector and a 25-segmented germanium detector. Nucl Phys A 758:150-153 (2005) https://doi.org/10.1016/j.nuclphysa.2005.05.031
  12. Han L, Rogers WL, Huh SS, Clinthorne N: Statistical performance evaluation and comparison of a compton medical imaging system and a collimated anger camera for higher energy photon imaging. Phys Med Biol 53:7029-7045 (2008) https://doi.org/10.1088/0031-9155/53/24/002
  13. Agostinelli S, Allison J, Amako K, et al: GEANT4-a simulation toolkit. Nucl Instr and Meth A 506:250-303 (2003) https://doi.org/10.1016/S0168-9002(03)01368-8
  14. Zoglauer A, Kanbach G: Doppler broadening as a lower limit to the angular resolution of next generation Compton telescopes. Proc SPIE-Int. Soc Opt Eng 4851:1302-1309 (2003).
  15. McIntyre JA, Paulson JT, Aguiar J, Allen RD: Improved sampling for a positron emission tomograph. IEEE Trans Nucl Sci 47:1242-1245 (2000) https://doi.org/10.1109/23.856578
  16. An SH, Seo H, Lee JH, Lee CS, Lee JS, Kim CH: Effect of detector parameters on the image quality of compton camera for $^{99m}Tc$. Nucl Instr and Meth A 571:251-254 (2007) https://doi.org/10.1016/j.nima.2006.10.075
  17. 이춘식, 이주한: Stack형 컴프턴 카메라의 영상 특성에 대한 몬테카를로 모사 연구. 새물리 53:130-136 (2006)
  18. Yang YF, Gono Y, Motomura S, Enomoto S, Yano Y: A compton camera for multitracer imaging. IEEE Trans Nucl Sci 48:656-661 (2001) https://doi.org/10.1109/23.940142