Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring

조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구

  • 최충석 (전주대학교 소방안전공학과)
  • Published : 2009.12.01

Abstract

This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

Keywords

References

  1. Kurt Nowak, "Zwanzig Jahre FI-Schutzschaltung Chronologieund Entwicklung varianten" pp.7-9, aus de 16/, 1978
  2. A.W. Smoot, N. Magan, "Method of Calculating electrical body impedance and equipment for measuring leakage currents", p.298, Underwiters Laboratories, USA, 1985
  3. Walter F.Hart, P.E., "A Five-part Resistor-Capacitor Network for measurement of Voltage and Current Levels Related to Electric Shock and Burns", pp.183-190, Electrical Shock Safety Criteria, 1985
  4. 최충석, 고재완, "배선 일체화된 조명등기구의 작업지시서 개발에 관한 연구", 대한전기학회논문지 Vol.58P No.2, pp.196-201, 2009
  5. 최충석 외 5, "전기화재공학", 도서출판 동화기술, pp.193-197, 2004
  6. C.S. Choi et al, "Flame Spread and Damaged Properties of RCD Cases by Tracking", IEEJ Trans. PE, Vol.127, No.1, pp.321-326, 2007 https://doi.org/10.1541/ieejpes.127.321
  7. IEC 60943, "Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals", 2nd edition, 1998
  8. IEC 60050-441, "International Electrotechnical Vocabulary(IEV) Chapter 441: Switch gear and controlgear and fuses", 1984
  9. IEC 60085, "Thermal evaluation and classification of electrical insulation", 1984
  10. IEC 60216-1, "Guide for the determination of thermal endurance properties of electrical insulating materials part 1: general guideline for aging procedures and evaluation of the test results", 1990
  11. 최충석, 고재완, "조명등기구 배선 커넥터의 전기적 특성 평가에 관한 연구", 대한전기학회 전기설비추계학술대회논문지, pp.165-168, 2009.