Dehydration and RDF Production of Organic Sludge with Hydrothermal Pre-treatment Process

증기열 전처리공정을 이용한 유기성 슬러지의 건조 및 성형연료화

  • Published : 2009.12.01

Abstract

This paper suggests the dehydration and RDF(Refuse Derived Fuel) production of organic sludge, livestock manure and sewerage sludge causing environmental problems, with hydrothermal pre-treatment process. The renewable technology from the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The hydrothermal pre-treatment process promotes to evaporate moisture in the sludge after being shortly treated in a reactor, which is supplied steam and heat by an external boiler, due to the pressure with steam breaks the cell walls of the sludge, so this process removes the internal moisture of the cell. Then, the treated sludge(solid-state) is mixed with waste vinyls called RDF(6,706kcal/kg).

Keywords

References

  1. 김준현 외, "하이브리드형 반응기를 이용한 분뇨, 축산폐수, 하수슬러지 및 음식물쓰레기의 고효율 바이오 가스생산 및 재활용 기술개발", 산업자원부 에너지.자원기술개발사업 최종보고서, pp. 17-20 (2007).
  2. 김윤호 외, "가축분뇨 자원화기술 연구성과", 농촌진흥청 연구관리국 연구성과, pp. 9-13 (2007)
  3. 환경부, "하수슬러지관리계획수립지침", 환경부 계획수립 지침서, pp. 3-17 (2006)
  4. N. Katsiris et al., "Bound water content of biological sludges in relation to filtration and dewatering", Water Res. 21(11), pp. 1319-1327 (1987) https://doi.org/10.1016/0043-1354(87)90004-2
  5. K. R. Tsang et al., "Moisture Distribution in Sludge", Water Sci. Tech., Vol. 22, No. 12, pp.135-142 (1990)
  6. P. A. Vesilind, "The role of water in sludge dewatering", Water Environ. Res. 66(1), pp. 4-11 (1994) https://doi.org/10.2175/WER.66.1.2
  7. E. J. Neyens et al., "A Review of Thermal Sludge Pre-treatment Process to Improve Dewaterability", Journal of Hazardous Materials, No. B98, pp. 51-67 (2003)
  8. J. A. Muller, "Prospects and problems of sludge pre-treatment processes", Water Sci. Tech. 44(10), pp. 121-128 (2001)
  9. U. K. Moller, Water Binding in Sludge Characteristics and Behaviour, NATO ASI Series E, Appl. Sci., No. 66, pp.182-194 (1967)
  10. P.Lowe, "Development in the Thermal Drying of Sewage", Sludge, J. CIWEM, pp.306-316 (1995)
  11. 전원표, "회전건조기에서 고함수솔 유기성 슬러지 입자의 건조특성 연구", 호서박사학위 논문, 2001
  12. Mujumdar, A. S., in A. S. Mujumdar(Ed.), "Handbook of Industrial Drying", Ch. 35, 2nd ed., Marcel Dekker, Inc., New York, NY (1995)
  13. 김옥신 외, "과열 증기 이용 친환경 건조기술", 한국화학공학회논문지, Vol. 46, No. 2, pp. 258-273 (2008)
  14. J. P. Schwartze et al., "The evaporation of water into air of different humidities and the inversion temperature phenomenon", International Journal of Heat and Mass Transfer 43, pp. 1791-1800 (2000) https://doi.org/10.1016/S0017-9310(99)00249-5
  15. E. P. Volchkov et al., "Finding the inversion temperature for water evaporation into an air–steam mixture", International Journal of Heat and Mass Transfer 50, pp. 2101-2106 (2007) https://doi.org/10.1016/j.ijheatmasstransfer.2006.11.010
  16. K. Yoshikawa, "폐기물 처리기술 개발 및 정책동향", 한.일 국제세미나 발표자료, 2007
  17. Marisamy Muthuraman et al., "Characteristics of co-combustion and kinetic study on hydrothermally treated municipal solid waste with different rank coals: A thermogravimetric analysis", Applied Energy, 2009
  18. 박종배 외, "신재생에너지 사업의 청정개발체제 사전 타당성 평가 프로그램 개발", 대한전기학회 하계학술대회 논문집A, pp. 420-421 (2006)
  19. 심대섭 외, "TGA를 사용한 고분자 재료의 내열 수명예측", 전기학회논문지 C, Vol.51, pp.473-478 (2002)