전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가

Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil

  • 발행 : 2009.12.01

초록

This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

키워드

참고문헌

  1. 김정부 외, "변전설비 진단기술 개발 연구", 한국전력공사 전력연구원, pp. 24-30, 1998. 1
  2. 송일근 외, "지중배전용 변압기 신뢰도 향상에 관한 연구", 한국전력공사 전력연구원, pp. 1-4, 2006. 3
  3. 강성준 외, "전력용 변압기의 점검기준에 관한 연구", 한국전기안전공사 전기안전기술연구원, pp. 28-42, 2000. 12
  4. ASTM D 150, "Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation", ASTM International, pp. 2-6, 2004
  5. ASTM D 924, "Standard Test Methods for Dissipation Factor(or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids", ASTM International, pp. 5-7, 2008. 11
  6. W. C. Heerens, "Application of Capacitance Techniques in Sensor Design", J. Phys. E:Sci. Instrum, Vol. 19. pp. 897-905, 1986 https://doi.org/10.1088/0022-3735/19/11/002
  7. A. H. Scott and H. L. Curtis, "Edge Correction in the Determination of Dielectric Constant", J. Research of National Bureau of Standards, Vol. 22, pp. 747-775, 1939 https://doi.org/10.6028/jres.022.008
  8. 김주한, 한상옥, 최남호, 강전홍, 김한준, "전산해석을 통한 액체 유전체용 정전용량형 센서설계", 2003년도 대한전기학회 고전압 및 방전기술연구회 춘계학술대회, pp. 96-98, 2003. 5
  9. 김주한, 한상옥, "전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발", 대한전기학회 하계학술대회, pp. 2061-2062, 2009. 7
  10. 이래덕, 김한준. P. Semenov, "크로스 커패시턴스 원리를 이용한 액체의 유전상수 정밀측정", 새물리 Vol.40, No. 2, pp. 97-102, 2000. 2
  11. ANSI/IEEE Standard C57.91-1981, "IEEE guide for loading mineral-oil-immersed overhead and pad-mounted distribution transformers rated 500 kVA and less with 65 degrees C or 55 degrees C average winding rise", American National Standards Institute, pp. 11-13, 1981. 7